Cysteine Accessibility in ClC-0 Supports Conservation of the ClC Intracellular Vestibule
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
ClC chloride channels, which are ubiquitously expressed in mammals, have a unique double-barreled structure, in which each monomer forms its own pore. Identification of pore-lining elements is important for understanding the conduction properties and unusual gating mechanisms of these channels. Structures of prokaryotic ClC transporters do not show an open pore, and so may not accurately represent the open state of the eukaryotic ClC channels. In this study we used cysteine-scanning mutagenesis and modification (SCAM) to screen >50 residues in the intracellular vestibule of ClC-0. We identified 14 positions sensitive to the negatively charged thiol-modifying reagents sodium (2-sulfonatoethyl)methanethiosulfonate (MTSES) or sodium 4-acetamido-4'-maleimidylstilbene-2'2-disulfonic acid (AMS) and show that 11 of these alter pore properties when modified. In addition, two MTSES-sensitive residues, on different helices and in close proximity in the prokaryotic structures, can form a disulfide bond in ClC-0. When mapped onto prokaryotic structures, MTSES/AMS-sensitive residues cluster around bound chloride ions, and the correlation is even stronger in the ClC-0 homology model developed by Corry et al. (2004). These results support the hypothesis that both secondary and tertiary structures in the intracellular vestibule are conserved among ClC family members, even in regions of very low sequence similarity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loss of the ClC-7 Chloride Channel Leads to Osteopetrosis in Mice and Man
Kornak, U., Kasper, D., Bösl, M. R., Kaiser, E., Schweizer, M., Schulz, A., Friedrich, W., Delling, G., & Jentsch, T. J. (2001) · Cell · doi:10.1016/s0092-8674(01)00206-9 · Cited by 995
Wilson, G. G., & Karlin, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.3.1241 · Cited by 138
STRUCTURE AND FUNCTION OF CLC CHANNELS
Chen, T.-Y. (2005) · Annual Review of Physiology · doi:10.1146/annurev.physiol.67.032003.153012 · Cited by 118
Cited by
Ion channels versus ion pumps: the principal difference, in principle
Gadsby, D. C. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2668 · Cited by 524
CLC Chloride Channels and Transporters: Structure, Function, Physiology, and Disease
Jentsch, T. J., & Pusch, M. (2018) · Physiological Reviews · doi:10.1152/physrev.00047.2017 · Cited by 448
CLC Chloride Channels and Transporters: From Genes to Protein Structure, Pathology and Physiology
Jentsch, T. J. (2008) · Critical Reviews in Biochemistry and Molecular Biology · doi:10.1080/10409230701829110 · Cited by 405
Chloride Channels: Often Enigmatic, Rarely Predictable
Duran, C., Thompson, C. H., Xiao, Q., & Hartzell, H. C. (2010) · Annual Review of Physiology · doi:10.1146/annurev-physiol-021909-135811 · Cited by 338
ClC chloride channels viewed through a transporter lens
Miller, C. (2006) · Nature · doi:10.1038/nature04713 · Cited by 313
Metadata
- Authors
- Engh, A. M., & Maduke, M.
- Venue
- The Journal of General Physiology
- Publisher
- Rockefeller University Press
- Published
- 2005-05-16
- Volume
- 125
- Issue
- 6
- Pages
- 601-617
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2164927499
- Cited by
- 56
- References
- 3
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.