The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
The permeability of endplate channels to monovalent and divalent metal cations.
Open accessAbstract
The relative permeability of endplate channels to monovalent and divalent metal ions was determined from reversal potentials. Thallium is the most permeant ion with a permeability ratio relative to Na+ of 2.5. The selectivity among alkali metals is weak with a sequence, Cs+ greater than Rb+ greater than K+ greater than Na+ greater than Li+, and permeability ratios of 1.4, 1.3, 1.1, 1.0, and 0.9. The selectivity among divalent ions is also weak, with a sequence for alkaline earths of Mg++ greater than Ca++ greater than Ba++ greater than Sr++. The transition metal ions Mn++, Co++, Ni++, Zn++, and Cd++ are also permeant. Permeability ratios for divalent ions decreased as the concentration of divalent ion was increased in a manner consistent with the negative surface potential theory of Lewis (1979 J. Physiol. (Lond.). 286: 417--445). With 20 mM XCl2 and 85.5 mM glucosamine.HCl in the external solution, the apparent permeability ratios for the alkaline earth cations (X++) are in the range 0.18--0.25. Alkali metal ions see the endplate channel as a water-filled, neutral pore without high-field-strength sites inside. Their permeability sequence is the same as their aqueous mobility sequence. Divalent ions, however, have a permeability sequence almost opposite from their mobility sequence and must experience some interaction with groups in the channel. In addition, the concentrations of monovalent and divalent ions are increased near the channel mouth by a weak negative surface potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stability constants of metal-ion complexes
Sillén, L. G., Martell, A. E., Bjerrum, J., & Schwarzenbach, G. (1964) · Medical Entomology and Zoology · Cited by 3,983
The effect of sodium ions on the electrical activity of the giant axon of the squid
Hodgkin, A. L., & Katz, B. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004310 · Cited by 3,520
Potential, impedance, and rectification in membranes
Goldman, D. E. (1943) · Journal of General Physiology · doi:10.1085/jgp.27.1.37 · Cited by 2,777
An analysis of the end‐plate potential recorded with an intra‐cellular electrode
Fatt, P., & Katz, B. (1951) · The Journal of Physiology · doi:10.1113/jphysiol.1951.sp004675 · Cited by 1,400
Cation selective glass electrodes and their mode of operation
Eisenman, G. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86959-8 · Cited by 852
Local anaesthetics transiently block currents through single acetylcholine‐receptor channels.
Neher, E., & Steinbach, J. H. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012267 · Cited by 844
Biological Membranes: The Physical Basis of Ion and Nonelectrolyte Selectivity
Diamond, J. M., & Wright, E. M. (1969) · Annual Review of Physiology · doi:10.1146/annurev.ph.31.030169.003053 · Cited by 696
Negative surface charge near sodium channels of nerve: divalent ions, monovalent ions, and pH
Hille, B., Woodhull, M., & Shapiro, B. I. (1975) · Philosophical Transactions of the Royal Society of London. B, Biological Sciences · doi:10.1098/rstb.1975.0011 · Cited by 589
Self-citationPotassium channels as multi-ion single-file pores.
Hille, B., & Schwarz, W. (1978) · The Journal of general physiology · doi:10.1085/jgp.72.4.409 · Cited by 522
Self-citationCONDUCTANCE FLUCTUATIONS AND IONIC PORES IN MEMBRANES
Neher, E., & Stevens, C. F. (1977) · Annual Review of Biophysics and Bioengineering · doi:10.1146/annurev.bb.06.060177.002021 · Cited by 508
Cited by
MacDermott, A. B., Mayer, M. L., Westbrook, G. L., Smith, S. J., & Barker, J. L. (1986) · Nature · doi:10.1038/321519a0 · Cited by 1,835
Ascher, P., & Nowak, L. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017078 · Cited by 819
Iino, M., Ozawa, S., & Tsuzuki, K. (1990) · The Journal of Physiology · doi:10.1113/jphysiol.1990.sp018060 · Cited by 497
Mulle, C., Choquet, D., Korn, H., & Changeux, J.-P. (1992) · Neuron · doi:10.1016/0896-6273(92)90115-t · Cited by 351
alpha-Bungarotoxin-sensitive hippocampal nicotinic receptor channel has a high calcium permeability
Castro, N. G., & Albuquerque, E. X. (1995) · Biophysical Journal · doi:10.1016/s0006-3495(95)80213-4 · Cited by 273
Metadata
- Authors
- Adams, D. J., Dwyer, T. M., & Hille, B.
- Venue
- The Journal of general physiology
- Publisher
- Rockefeller University Press
- Published
- 1980-05-01
- Volume
- 75
- Issue
- 5
- Pages
- 493-510
- ISSN
- 0022-1295 (ISSN-L)
- 1540-7748
- OpenAlex
- W2126814404
- Cited by
- 331
- References
- 25
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The permeability of endplate channels to monovalent and divalent metal cations. https://app.cochat.ai/papers/10.1085/jgp.75.5.493
- The paper
- Adams, D. J., Dwyer, T. M., & Hille, B. (1980). The permeability of endplate channels to monovalent and divalent metal cations. The Journal of general physiology. https://doi.org/10.1085/jgp.75.5.493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.