Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Using Strong Lines to Estimate Abundances in Extragalactic H ii Regions and Starburst Galaxies

Open access
Kewley, L. J., Dopita, M. A.·2002·The Astrophysical Journal Supplement Series

Abstract

We have used a combination of stellar population synthesis and photoionization models to develop a set of ionization parameter and abundance diagnostics based only on the use of the strong optical emission lines. These models are applicable to both extragalactic H II regions and star-forming galaxies. We show that, because our techniques solve explicitly for both the ionization parameter and the chemical abundance, the diagnostics presented here are an improvement on earlier techniques based on strong emission-line ratios. Our techniques are applicable at all metallicities. In particular, for metallicities above half solar, the ratio [N II]/[O II] provides a very reliable diagnostic since it is ionization parameter independent and does not have a local maximum. This ratio has not previously been used historically because of worries about reliable calibration over such a long baseline, and reddening correction concerns. However, we show that the use of classical reddening curves and standard calibration are quite sufficient to allow this [N II]/[O II] diagnostic to be used with confidence as a reliable abundance indicator. As we had shown, the commonly used abundance diagnostic R 23 depends strongly on the ionization parameter, while the commonly used ionization parameter diagnostic [O III]/[O II] depends strongly on abundance. The iterative method of solution presented here allows both of these parameters to be obtained without recourse to the use of temperature-sensitive line ratios involving faint emission lines. We compare three commonly used abundance diagnostic techniques and show that individually, they contain systematic and random errors. This is a problem affecting many abundance diagnostics, and the errors generally have not been properly studied or understood due to the lack of a reliable comparison abundance, except for very low metallicities, where the [O III] λ4363 auroral line is used. Here we show that the average of these techniques provides a fairly reliable comparison abundance indicator against which to test new diagnostic methods. The cause of the systematic effects are discussed, and we present a new "optimal" abundance diagnostic method based on the use of line ratios involving [N II], [O II], [O III], [S II], and the Balmer lines. This combined diagnostic appears to suffer no apparent systematic errors, can be used over the entire abundance range and significantly reduces the random error inherent in previous techniques. Finally, we give a recommended procedure for the derivation of abundances in the case that only spectra of limited wavelength coverage are available so that the optimal method can no longer be used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1086/341326

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 1,167

Metadata

Authors
Kewley, L. J., & Dopita, M. A.
Venue
The Astrophysical Journal Supplement Series
Published
2002-09
Volume
142
Issue
1
Pages
35-52
ISSN
  • 0067-0049 (ISSN-L)
  • 1538-4365
OpenAlex
W2032949105
Cited by
1,167
References
1
FWCI
14.60
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Using Strong Lines to Estimate Abundances in Extragalactic H ii Regions and Starburst Galaxies. https://app.cochat.ai/papers/10.1086/341326
The paper
Kewley, L. J., & Dopita, M. A. (2002). Using Strong Lines to Estimate Abundances in Extragalactic H ii Regions and Starburst Galaxies. The Astrophysical Journal Supplement Series. https://doi.org/10.1086/341326

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.