Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 536

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

SMART‐COP: A Tool for Predicting the Need for Intensive Respiratory or Vasopressor Support in Community‐Acquired Pneumonia

Charles, Patrick G. P., Wolfe, Rory, Whitby, Michael, Fine, Michael J., Fuller, Andrew J., Stirling, Robert, Wright, Alistair A., Ramirez, Julio A., Christiansen, Keryn J., Waterer, Grant W., Pierce, Robert J., Armstrong, John G., Korman, Tony M., Holmes, Peter, Obrosky, D. Scott, Peyrani, Paula, Johnson, Barbara, Hooy, Michelle, Australian Community‐Acquired Pneumonia Study Collaboration, Grayson, M. Lindsay · 2008 · Clinical Infectious Diseases

Abstract

BACKGROUND: Existing severity assessment tools, such as the pneumonia severity index (PSI) and CURB-65 (tool based on confusion, urea level, respiratory rate, blood pressure, and age >or=65 years), predict 30-day mortality in community-acquired pneumonia (CAP) and have limited ability to predict which patients will require intensive respiratory or vasopressor support (IRVS). METHODS: The Australian CAP Study (ACAPS) was a prospective study of 882 episodes in which each patient had a detailed assessment of severity features, etiology, and treatment outcomes. Multivariate logistic regression was performed to identify features at initial assessment that were associated with receipt of IRVS. These results were converted into a simple points-based severity tool that was validated in 5 external databases, totaling 7464 patients. RESULTS: In ACAPS, 10.3% of patients received IRVS, and the 30-day mortality rate was 5.7%. The features statistically significantly associated with receipt of IRVS were low systolic blood pressure (2 points), multilobar chest radiography involvement (1 point), low albumin level (1 point), high respiratory rate (1 point), tachycardia (1 point), confusion (1 point), poor oxygenation (2 points), and low arterial pH (2 points): SMART-COP. A SMART-COP score of >or=3 points identified 92% of patients who received IRVS, including 84% of patients who did not need immediate admission to the intensive care unit. Accuracy was also high in the 5 validation databases. Sensitivities of PSI and CURB-65 for identifying the need for IRVS were 74% and 39%, respectively. CONCLUSIONS: SMART-COP is a simple, practical clinical tool for accurately predicting the need for IRVS that is likely to assist clinicians in determining CAP severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1086/589754

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

Metadata

Authors
Charles, P. G. P., Wolfe, R., Whitby, M., Fine, M. J., Fuller, A. J., Stirling, R., Wright, A. A., Ramirez, J. A., Christiansen, K. J., Waterer, G. W., Pierce, R. J., Armstrong, J. G., Korman, T. M., Holmes, P., Obrosky, D. S., Peyrani, P., Johnson, B., Hooy, M., Australian Community‐Acquired Pneumonia Study Collaboration, & Grayson, M. L.
Venue
Clinical Infectious Diseases
Published
2008-08
Volume
47
Issue
3
Pages
375-384
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2133008785
Cited by
536
References
25
FWCI
22.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.