CoChat

Enhanced Diagnosis of Pneumococcal Meningitis with Use of the Binax NOW Immunochromatographic Test of Streptococcus pneumoniae Antigen: A Multisite Study

Open access
Moïsi, Jennifer C., Saha, Samir K., Falade, Adegoke G., Njanpop‐Lafourcade, Berthe‐Marie, Oundo, Joseph, Zaidi, Anita K. M., Afroj, Shirin, Bakare, R. A., Buss, Julie K., Lasi, Razzaq, Mueller, Judith, Odekanmi, A. A., Sangaré, Lassana, Scott, J. Anthony G., Deloria Knoll, Maria, Levine, Orin S., Gessner, Bradford D. · 2009 · Clinical Infectious Diseases
Cited by 86

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Accurate etiological diagnosis of meningitis in developing countries is needed, to improve clinical care and to optimize disease-prevention strategies. Cerebrospinal fluid (CSF) culture and latex agglutination testing are currently the standard diagnostic methods but lack sensitivity. METHODS: We prospectively assessed the utility of an immunochromatographic test (ICT) of pneumococcal antigen (NOW Streptococcus pneumoniae Antigen Test; Binax), compared with culture, in 5 countries that are conducting bacterial meningitis surveillance in Africa and Asia. Most CSF samples were collected from patients aged 1-59 months. RESULTS: A total of 1173 CSF samples from suspected meningitis cases were included. The ICT results were positive for 68 (99%) of the 69 culture-confirmed pneumococcal meningitis cases and negative for 124 (99%) of 125 culture-confirmed bacterial meningitis cases caused by other pathogens. By use of culture and latex agglutination testing alone, pneumococci were detected in samples from 7.4% of patients in Asia and 15.6% in Africa. The ICT increased pneumococcal detection, resulting in similar identification rates across sites, ranging from 16.2% in Nigeria to 20% in Bangladesh. ICT detection in specimens from culture-negative cases varied according to region (8.5% in Africa vs. 18.8% in Asia; P< .001), prior antibiotic use (24.2% with prior antibiotic use vs. 12.2% without; P< .001), and WBC count (9.0% for WBC count of 10-99 cells/mL, 22.1% for 100-999 cells/mL, and 25.4% for >or=1000 cells/mL; P< .001 by test for trend). CONCLUSIONS: The ICT provided substantial benefit over the latex agglutination test and culture at Asian sites but not at African sites. With the addition of the ICT, the proportion of meningitis cases attributable to pneumococci was determined to be similar in Asia and Africa. These results suggest that previous studies have underestimated the proportion of pediatric bacterial meningitis cases caused by pneumococci.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1086/596481

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 86

Metadata

Authors
Moïsi, J. C., Saha, S. K., Falade, A. G., Njanpop‐Lafourcade, B., Oundo, J., Zaidi, A. K. M., Afroj, S., Bakare, R. A., Buss, J. K., Lasi, R., Mueller, J., Odekanmi, A. A., Sangaré, L., Scott, J. A. G., Deloria Knoll, M., Levine, O. S., & Gessner, B. D.
Venue
Clinical Infectious Diseases
Published
2009-03
Volume
48
Issue
s2
Pages
S49-S56
ISSN
  • 1058-4838 (ISSN-L)
  • 1537-6591
OpenAlex
W2150252438
Cited by
86
References
4
FWCI
5.16
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhanced Diagnosis of Pneumococcal Meningitis with Use of the Binax NOW Immunochromatographic Test of Streptococcus pneumoniae Antigen: A Multisite Study. https://app.cochat.ai/papers/10.1086/596481
The paper
Moïsi, J. C., Saha, S. K., Falade, A. G., Njanpop‐Lafourcade, B., Oundo, J., Zaidi, A. K. M., Afroj, S., Bakare, R. A., Buss, J. K., Lasi, R., Mueller, J., Odekanmi, A. A., Sangaré, L., Scott, J. A. G., Deloria Knoll, M., Levine, O. S., & Gessner, B. D. (2009). Enhanced Diagnosis of Pneumococcal Meningitis with Use of the Binax NOW Immunochromatographic Test of Streptococcus pneumoniae Antigen: A Multisite Study. Clinical Infectious Diseases. https://doi.org/10.1086/596481

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.