X-ray plane-wave topography observation of the phase contrast from a non-crystalline object
The DOI matches its Crossref record.
Abstract
A technique for observation of the inner structure of objects is proposed. The sensitivity to variations in direction of the primary pseudo-plane beam which occurs on boundaries between media with slight differences in density values is impressive. Two types of contrasts are pointed out: 'area contrast' caused by slight deviation of the primary beam and 'boundary contrast'. Basic principles and experimental results are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
X-ray phase imaging with a grating interferometer
Weitkamp, T., Diaz, A., David, C., Pfeiffer, F., Stampanoni, M., Cloetens, P., & Ziegler, E. (2005) · Optics Express · doi:10.1364/opex.13.006296 · Cited by 1,211
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Quantitative Phase Imaging Using Hard X Rays
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D., & Barnea, Z. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2961 · Cited by 675
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Coherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Contrast and resolution in imaging with a microfocus x-ray source
Pogany, A., Gao, D., & Wilkins, S. W. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148194 · Cited by 476
Dynamical Theory of X-Ray Diffraction
Authier, A. (2003) · doi:10.1093/acprof:oso/9780198528920.001.0001 · Cited by 331
Development of phase-contrast X-ray imaging techniques and potential medical applications
Zhou, S.-A., & Brahme, A. (2008) · Physica Medica · doi:10.1016/j.ejmp.2008.05.006 · Cited by 268
Phase retrieval in X-ray phase-contrast imaging suitable for tomography
Burvall, A., Lundström, U., Takman, P. A. C., Larsson, D. H., & Hertz, H. M. (2011) · Optics Express · doi:10.1364/oe.19.010359 · Cited by 263
High-resolution brain tumor visualization using three-dimensional x-ray phase contrast tomography
Pfeiffer, F., Bunk, O., David, C., Bech, M., Le Duc, G., Bravin, A., & Cloetens, P. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/23/010 · Cited by 199
“…classified into interferometric methods (Bonse and Hart 1965, Momose et al 2003, Weitkamp et al 2005), techniques using an analyzer (Davis et al 1995, Ingal and Beliaevskaya 1995, Chapman et al 1997), and free-space propagation methods (Snigirev et al 1995, Nugent et al 1996, Wilkins et al 1996).”
BackgroundMethodA method to extract quantitative information in analyzer-based x-ray phase contrast imaging
Pagot, E., Cloetens, P., Fiedler, S., Bravin, A., Coan, P., Baruchel, J., Härtwig, J., & Thomlinson, W. (2003) · Applied Physics Letters · doi:10.1063/1.1575508 · Cited by 198
Fast 3D reconstruction method for differential phase contrast X-ray CT
McCann, M. T., Nilchian, M., Stampanoni, M., & Unser, M. (2016) · Optics Express · doi:10.1364/oe.24.014564 · Cited by 28
Metadata
- Authors
- Ingal, V. N., & Beliaevskaya, E. A.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1995-11-14
- Volume
- 28
- Issue
- 11
- Pages
- 2314-2317
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2039387997
- Cited by
- 411
- References
- 0
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.