Timescales at the BIPM
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
This paper reviews the present status of the timescales established at the International Bureau of Weights and Measures (BIPM). We focus our attention on the calculation and the characteristics of Coordinated Universal Time (UTC) and present its applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The atomic international time (TAI) is the most commonly used realization of TT [56, 124].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [56]
Citations
Cites
Precise Point Positioning Using IGS Orbit and Clock Products
Kouba, J., & Héroux, P. (2001) · GPS Solutions · doi:10.1007/pl00012883 · Cited by 1,488
An Atomic Standard of Frequency and Time Interval: A Cæsium Resonator
ESSEN, L., & PARRY, J. V. L. (1955) · Nature · doi:10.1038/176280a0 · Cited by 305
Two-way time transfer via communication satellites
Kirchner, D. (1991) · Proceedings of the IEEE · doi:10.1109/5.84975 · Cited by 192 · cited 8×
“As of April 2011, 45% of the links in TAI/UTC are obtained using GPS single-frequency data, 37% from dualfrequency GPS receivers; most of the TWSTFT links are used in combination with GPS (PPP and P3), these totalling 12% of the time links.”
MethodInfluentialGPS All in View time transfer for TAI computation
Petit, G., & Jiang, Z. (2008) · Metrologia · doi:10.1088/0026-1394/45/1/006 · Cited by 148 · cited 2×
“Then advances in obtaining precise satellite orbits and clock parameters allowed the introduction of another technique, named All in View (AV) [19] that eliminates the constraint of having simultaneous observations, thus becoming independent of the length of the baseline for having suitable observed satellites.”
MethodSelf-citationTime transfer to TAI using geodetic receivers
Defraigne, P., & Petit, G. (2003) · Metrologia · doi:10.1088/0026-1394/40/4/307 · Cited by 126 · cited 1×
“The GPS links obtained using dual-frequency receivers, termed GPS P3 [20, 21], provide ionosphere-free data and allow clock comparisons with nanosecond statistical uncertainty or better.”
MethodSelf-citationBeiDou Navigation Satellite System and its time scales
Han, C., Yang, Y., & Cai, Z. (2011) · Metrologia · doi:10.1088/0026-1394/48/4/s13 · Cited by 126
Precise Point Positioning for TAI Computation
Petit, G., & Jiang, Z. (2008) · International Journal of Navigation and Observation · doi:10.1155/2008/562878 · Cited by 124 · cited 3×
“As of April 2011, 45% of the links in TAI/UTC are obtained using GPS single-frequency data, 37% from dualfrequency GPS receivers; most of the TWSTFT links are used in combination with GPS (PPP and P3), these totalling 12% of the time links.”
MethodSelf-citationComparative Study of Time Scale Algorithms
Tavella, P., & Thomas, C. (1991) · Metrologia · doi:10.1088/0026-1394/28/2/001 · Cited by 119
Fundamentals of two-way time transfers by satellite
Hanson, D. W. (2003) · Proceedings of the 43rd Annual Symposium on Frequency Control · doi:10.1109/freq.1989.68861 · Cited by 92 · cited 8×
“As of April 2011, 45% of the links in TAI/UTC are obtained using GPS single-frequency data, 37% from dualfrequency GPS receivers; most of the TWSTFT links are used in combination with GPS (PPP and P3), these totalling 12% of the time links.”
MethodInfluentialLong-term comparison of caesium fountain primary frequency standards
Parker, T. E. (2010) · Metrologia · doi:10.1088/0026-1394/47/1/001 · Cited by 76
Cited by
The International Pulsar Timing Array
Manchester, R. N. (2013) · Classical and Quantum Gravity · doi:10.1088/0264-9381/30/22/224010 · Cited by 253
Development of a pulsar-based time-scale
Hobbs, G., Coles, W., Manchester, R. N., Keith, M. J., Shannon, R. M., Chen, D., Bailes, M., Bhat, N. D. R., Burke-Spolaor, S., Champion, D., et al. (2012) · Monthly Notices of the Royal Astronomical Society · doi:10.1111/j.1365-2966.2012.21946.x · Cited by 186
The Coordinated Universal Time (UTC)
Panfilo, G., & Arias, E. F. (2019) · Metrologia · doi:10.1088/1681-7575/ab1e68 · Cited by 157
Self-citationA pulsar-based time-scale from the International Pulsar Timing Array
Hobbs, G. B., Guo, L., Caballero, R. N., Coles, W. A., Lee, K., Manchester, R. N., Reardon, D. J., Matsakis, D. N., Tong, M., Arzoumanian, Z., et al. (2019) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stz3071 · Cited by 108
“To provide stability over years and decades TAI is ‘steered’ by comparison with ‘primary and secondary representations of the second’ (presently caesium and rubidium fountains respectively) to keep the TAI second as close as possible to the SI second (Arias et al. 2011).”
BackgroundGeneration of UTC(PTB) as a fountain-clock based time scale
Bauch, A., Weyers, S., Piester, D., Staliuniene, E., & Yang, W. (2012) · Metrologia · doi:10.1088/0026-1394/49/3/180 · Cited by 104
“The decision was made initially to always use d estimated for the previous month and published at the end of Section 4 of Circular T, irrespective of the fact that d depends in a complicated way on the past contributions of several primary frequency standards [5, 15], not always including CSF1.”
MethodThe Nanohertz Gravitational Wave AstronomerPreprint
Taylor, S. R. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2105.13270 · Cited by 107
Millisecond Pulsars, their Evolution and Applications
Manchester, R. N. (2017) · Journal of Astrophysics and Astronomy · doi:10.1007/s12036-017-9469-2 · Cited by 67
Optical-Clock-Based Time Scale
Yao, J., Sherman, J. A., Fortier, T., Leopardi, H., Parker, T., McGrew, W., Zhang, X., Nicolodi, D., Fasano, R., Schäffer, S. A., et al. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.044069 · Cited by 69
“Beyond better local timekeeping, optical clocks offer improvements to International Atomic Time (TAI) and UTC [30].”
Liberating Clocks: Developing a Critical Horology to Rethink the Potential Of Clock Time
Bastian, M. (2017) · New Formations · doi:10.3898/newf:00.00.2017 · Cited by 58
Terahertz Vibrational Molecular Clock with Systematic Uncertainty at the 10−14 Level
Leung, K. H., Iritani, B., Tiberi, E., Majewska, I., Borkowski, M., Moszyński, R., & Zelevinsky, T. (2023) · Physical Review X · doi:10.1103/physrevx.13.011047 · Cited by 50
“8], T2 = 1 month corresponds to the time period for the publication of the Circular T [125], and the bracketed time explicitly states the duration over which the given fre-”
BackgroundInternational atomic time: Status and future challenges
Petit, G., Arias, E. F., & Panfilo, G. (2015) · Comptes Rendus Physique · doi:10.1016/j.crhy.2015.03.002 · Cited by 44
Self-citationCharacterization of a 450 km baseline GPS carrier-phase link using an optical fiber link
Droste, S., Grebing, C., Leute, J., Raupach, S. M. F., Matveev, A., Hänsch, T. W., Bauch, A., Holzwarth, R., & Grosche, G. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/8/083044 · Cited by 29
Chronometric Geodesy: Methods and Applications
Delva, P., Denker, H., & Lion, G. (2019) · Fundamental Theories of Physics · doi:10.1007/978-3-030-11500-5_2 · Cited by 28
“Therefore this convention is not practical to define global timescales such as the TAI (Temps Atomique International).”
MethodInfluentialFiber-Optic Time Transfer for UTC-Traceable Synchronization for Telecom Networks
Śliwczyński, Ł., Krehlik, P., Kołodziej, J., Imlau, H., Ender, H., Schnatz, H., Piester, D., & Bauch, A. (2017) · IEEE Communications Standards Magazine · doi:10.1109/mcomstd.2017.1600766st · Cited by 26
The coordinated universal time
Panfilo, G. (2016) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2016.7477951 · Cited by 20
Self-citationComprehensive Analysis of PPP-B2b Service and Its Impact on BDS-3/GPS Real-Time PPP Time Transfer
Tang, J. B., Lyu, D., Zeng, F., Ge, Y., & Zhang, R. (2022) · Remote Sensing · doi:10.3390/rs14215366 · Cited by 18
High accuracy continuous time transfer with GPS IPPP and T2L2
Leute, J., Petit, G., Exertier, P., Samain, É., Rovera, D., & Uhrich, P. (2018) · European Frequency and Time Forum · doi:10.1109/eftf.2018.8409043 · Cited by 20
“Space-based time transfer techniques in the microwave regime, GPS time transfer and Two-Way Satellite Time and Frequency Transfer (TWSTFT), play an important role in remote time and frequency comparisons and atomic time scales [1].”
BackgroundSelf-citationEvolution of timescales from astronomy to physical metrology
McCarthy, D. D. (2011) · Metrologia · doi:10.1088/0026-1394/48/4/s03 · Cited by 15
State space control of frequency standards
Koppang, P. (2016) · Metrologia · doi:10.1088/0026-1394/53/3/r60 · Cited by 14
A new approach to UTC calculation by means of the Kalman filter
Parisi, F., & Panfilo, G. (2016) · Metrologia · doi:10.1088/0026-1394/53/5/1185 · Cited by 13
Self-citationAtomic clock prediction algorithm: random pursuit strategy
Wang, Y. Z., Chen, Y., Gao, Y., Xu, Q., & Zhang, A. (2017) · Metrologia · doi:10.1088/1681-7575/aa6f62 · Cited by 13
Algorithm for Predicting [UTC–UTC(k)] by Means of Neural Networks
Miczulski, W., & Sobolewski, Ł. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2674778 · Cited by 13
Time Scales and Time Transformations Among Satellite Navigation Systems
Zhang, P., Xu, C., Hu, C., Chen, Y., & Zhao, J. (2012) · Lecture notes in electrical engineering · doi:10.1007/978-3-642-29175-3_45 · Cited by 10
Improving PPP timing and time transfer based on signal distortion biases calibration
Zang, M., Gong, X., Chen, Q., Gu, S., Guo, W., & Zhang, W. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ad8250 · Cited by 9
“With the development of GNSS, many applications have put forward higher requirements for the accuracy of time and frequency transfer [4, 5].”
Sobolewski, Ł. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8088796 · Cited by 9
“Each month BIPM determines the [UTC - UTC(k)] deviations for each UTC(k), which define the divergence of local timescale in relation to the UTC [1, 2, 3].”
BackgroundChen, S., Liu, Y., Li, X., Zhang, H., Qin, W., Duosheng, F., & Zhao, Z. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ada307 · Cited by 8
“In 2009, the International Bureau of Weights and Measures officially integrated GPS-based time transfer using precise point positioning (PPP) into the UTC time transfer system [3, 4].”
Sobolewski, Ł., & Miczulski, W. (2021) · Applied Sciences · doi:10.3390/app11125615 · Cited by 8
“The International Bureau of Weights and Measures (BIPM), based on strictly defined algorithms [1], determines the UTC scale (Universal Coordinated Time) on the basis of previously properly prepared and verified measurement data from local and remote comparisons of over 700 atomic clocks [2].”
MethodExperimental Verification of the Neural Network Predicting Procedure Applied for UTC(PL)
Sobolewski, Ł., Miczulski, W., & Czubla, A. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3116297 · Cited by 8
Analysis of Different Global Navigation Satellite Systems in Time Transfer
Hamza, G. G. (2022) · IEEE Communications Magazine · doi:10.1109/mcom.001.2100609 · Cited by 8
ATLAS: Orbit Determination and Time Transfer for a Lunar Radio Navigation System
Sesta, A., Durante, D., Boscagli, G., Cappuccio, P., Benedetto, M. D., di Stefano, I., Plumaris, M., Racioppa, P., IESS, L., Giordano, P., et al. (2025) · NAVIGATION Journal of the Institute of Navigation · doi:10.33012/navi.701 · Cited by 7
Zhang, A., Gao, Y., Liang, K., Wang, W., Yang, Z., Ning, D., & Fang, Z. (2013) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf-ifc.2013.6702192 · Cited by 7
Explicit ensemble mean clock synchronization for optimal atomic time scale generation
Ishizaki, T., Kawaguchi, T., Yano, Y., & Hanado, Y. (2026) · Metrologia · doi:10.1088/1681-7575/ae549a · Cited by 6
“In practice, a time scale, or standard time reference, is generated and maintained by regulating the frequency of local oscillators based on the ensemble time, i.e., the atomic time (TA) generated from multiple pairwise clock difference measurements [6].”
Research on time scale algorithm based on hydrogen masers
Jiang, M., Dong, S., & Wu, W. (2020) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2020.9153573 · Cited by 6
“[4].”
Predicting the Lithuanian Timescale UTC(LT) by means of GMDH neural network
Sobolewski, Ł. (2017) · Bulletin of the Military University of Technology · doi:10.5604/01.3001.0010.8179 · Cited by 6
Arias, E. F. (2012) · Review of Scientific Instruments · doi:10.1063/1.3681927 · Cited by 5
Self-citationZhu, F., Li, X., Hui-jun, Z., Luxi, H., & Xu, L. (2017) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2017.8089045 · Cited by 4
“Meanwhile we obtain the UTC-UTC(NTSC) representing actual UTC from BIPM Circular T[5].”
MethodSong, H., Dong, S., Wang, X., Jiang, M., Zhang, Y., Guo, D., & Zhang, J. (2024) · Acta Physica Sinica · doi:10.7498/aps.73.20231866 · Cited by 4
Enhanced stability for local atomic clock ensemble time scale using weighted moving average filter
Wang, Y., & Zhang, A. (2016) · IEEE International Conference on Mechatronics and Automation (ICMA) · doi:10.1109/icma.2016.7558864 · Cited by 4
“In this paper, the local atomic clock ensemble time scale is generated by the weighted moving average filter and ALGOS methods [15-17].”
MethodZero-value calibration of the BeiDou monitoring receiver
Zhu, F., Zhang, H., & Li, X. (2015) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi.2015.7494243 · Cited by 4
Bilicki, S. (2017) · theses.fr (ABES) · doi:10.70675/4b3e81f4z8872z4d16z8156z517133a256ac · Cited by 10
“In 1967 the Conférence Générale des Poids et Mesures (CGPM) defined the second as «the duration of 9 192 631 770 periods of the radiation corresponding to the transition between the two hyperfine levels of the ground state of the cesium 133 atom» [1,190,191].”
BackgroundSobolewski, Ł. (2024) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2024.109448 · Cited by 3
Timescale Algorithm at CSIR-NPL
Olaniya, M. P., Yadav, S., Kandpal, P., Dixit, M., & Agarwal, A. (2019) · URSI Asia-Pacific Radio Science Conference · doi:10.23919/ursiap-rasc.2019.8738334 · Cited by 3
“The presented algorithm is made for steering the UTC(NPLI) towards the UTC [1-4] and this algorithm taking weighted average of an AHM and five Cesium clocks.”
MethodA NEW ALGORITHM FOR CLOCK WEIGHTS FOR THE SIM TIME SCALE
Diaz, N. (2012) · Cited by 2
Methods of time series preparation based on UTC and UTCr scales for predicting the [UTC-UTC(PL)]
Sobolewski, Ł., & Miczulski, W. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012040 · Cited by 2
Evaluation of GNSS timing performance based on circular T and analysis of system time offset
Zhu, F., Li, X., & Duosheng, F. (2013) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi.2013.6743222 · Cited by 2
Absolute Calibration of the BDS-3 Receiver Based on Global Signal System
Luxi, H., Zhu, F., & Li, X. (2018) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2018.8597582 · Cited by 2
“Therefore the pseudorange reference value actually arriving at the receiver is: ' ( ) s s sim clk tron inon sim c R c (2)”
The caesium fountain clock at the NRC
Beattie, S., Jian, B., Alcock, J. A., & Gertsvolf, M. (2022) · Canadian Journal of Physics · doi:10.1139/cjp-2022-0175 · Cited by 2
Time Scale Control Using Dynamic GMDH Neural Network Forecasting Based on Real Measurement Data
Sobolewski, Ł. (2025) · Applied Sciences · doi:10.3390/app15126932 · Cited by 1
“For this purpose, a direct comparison of a given UTC(k) with the global UTC scale, determined by the International Bureau of Weights and Measures, BIPM (in French, Bureau International des Poids et Mesures) is required [2–4].”
Pulsars as Natural Oscillators for Long-Term Deep-Space Missions
Iyer, V., & Bandi, T. (2026) · NAVIGATION Journal of the Institute of Navigation · doi:10.33012/navi.733 · Cited by 2
An Algorithm for a Group Time Scale Using a Moving Average Over Multiple Time Scales
Podogova, S. D., Геннадьевич, М. К., Medvedev, S. Y., & Blinov, I. Y. (2015) · Measurement Techniques · doi:10.1007/s11018-015-0749-4 · Cited by 1
A generating procedure for local atomic clock ensemble time scale
Wang, Y., & Zhang, A. (2017) · IEEE Advanced Information Technology, Electronic and Automation Control Conference (IAEAC) · doi:10.1109/iaeac.2017.8054040 · Cited by 1
“However, the Circular T reported by BIPM is not real time, there is a window period (UTC: about 45 days, UTCr: about 10 days) [1].”
BackgroundMethodInfluentialMini Robot for Calibration of Stopwatch/Timer
Perangin-Angin, W. K., Agmal, S., Boynawan, A. M., Pawestri, Y. I., Ratnaningsih, R., Hapiddin, A., & Azzumar, M. (2019) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1230/1/012029 · Cited by 1
Design of AtomicTime Scale System Steered by Cesium Atomic Fountain Clock
Zhu, J., Zhao, W., Gao, Y., & Jiang, Y. (2021) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi52946.2021.9679500 · Cited by 1
“Time-keeping laboratories in various countries can steer the atomic time scales of various countries through the International Time Bulletin published by BIPM [3-4].”
BackgroundInfluentialA dataset of time and frequency system
Zhang, Y., Wang, Y., Yuan, H., & Dong, S. (2020) · China Scientific Data · doi:10.11922/csdata.2019.0077.zh · Cited by 1
Pulsar timing and a pulsar-based timescale
Manchester, R. N., & Hobbs, G. B. (2012) · jsrs
Traceability of optical frequency to SI second via UTC(NIM)
Wang, Y., Lin, Y., Gao, Y., & Zhang, A. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.970450
“TAI is a realization of Terrestrial Time (TT), a coordinate time with scale unit the SI second in the geocentric reference system [11].”
BackgroundReducing the Effects of Correlation Between Multiple Clocks on Clock Ensemble Time Scale
Xu, Q., Wang, Y., Jia, Z., Zhang, A., & Chen, Y. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272121
“(8) Here, %̄! = %! , and using = in (2), the estimate for the total set as the average over the subsets is ̂ = .”
BackgroundMethodInfluentialZeng, F., Tang, J. B., Lyu, D., Wang, B., Sun, X., Zhang, W., & Jiang, L. (2023) · International Conference on Machine Learning, Cloud Computing and Intelligent Mining (MLCCIM) · doi:10.1109/mlccim60412.2023.00010
Terahertz Vibrational Molecular Clock
Leung, K. H. (2023) · Springer theses · doi:10.1007/978-3-031-47647-1_5 · Cited by 1
A redundant subspace weighting procedure for clock ensemble
徐, H. 海. X., 陈, Y. 煜. C., 刘, M.-C. 默. L., & 王, Y.-Z. 玉. W. (2024) · Chinese Physics B · doi:10.1088/1674-1056/ad1b43
Metrology and statistics : from clocks to millisecond pulsars
Baudiquez, A. (2022) · theses.fr (ABES) · doi:10.70675/9817fc9ez000az4015zb9d3z351b92132c0a
Li, D., Xu, Q., Jia, Z., & Wang, Y. (2023) · International Conference on Network and Information Systems for Computers (ICNISC) · doi:10.1109/icnisc60562.2023.00026
Research on An Improved Time Scale Algorithm of Time-keeping Atomic Clocks
Jiang, M., & Zhang, Y. (2025) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2025.10870079
Richard, É. (2016) · theses.fr (ABES) · doi:10.70675/131e6aeez2f92z4ecczb18fzbb43d15cc36f · Cited by 1
PERFORMANCE ANALYSIS OF THE LOCAL TIME SCALE (UTC(INXE)) USING ALGORITHMS OF ARTIFICIAL INTELLIGENCE
Goncalves, D. S., do Prado, C. B., & Tarelho, L. V. G. (2025) · doi:10.59161/qoor4216
High-Accuracy Optical Frequency Metrology: traceability at the 1E-17 level
Barbieri, P. (2020) · PORTO@Iris
Pulsar-assisted atomic clock stabilization: fusion and steering with pulsar ensembles
Iyer, V., Gokie, E. J., & Bandi, T. (2026) · Advances in Space Research · doi:10.1016/j.asr.2026.09.081
Metadata
- Authors
- Arias, E. F., Panfilo, G., & Petit, G.
- Affiliations
- Observatoire de Paris (FR)
- Bureau international des poids et mesures (FR)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2011-07-20
- Volume
- 48
- Issue
- 4
- Pages
- S145-S153
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W1997891494
- Semantic Scholar
- caeb3b561463fad57af42196265df5fe253954e1
- Cited by
- 64
- References
- 28
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 5 · 2023: 5 · 2022: 4 · 2021: 4 · 2020: 2 · 2019: 7 · 2018: 2 · 2017: 10 · 2016: 6 · 2015: 4 · 2013: 3 · 2012: 6
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- time scales, Coordinated Universal Time, time and frequency metrology, BIPM
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.