CoChat

Long-term comparison of caesium fountain primary frequency standards

Parker, Thomas E · 2010 · Metrologia
Cited by 76

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

There are currently nine caesium fountain primary frequency standards regularly reporting calibrations of International Atomic Time to the Bureau International des Poids et Measures (BIPM). An investigation has been carried out using data from the BIPM publication Circular T to evaluate the frequency differences among these standards and to determine whether these offsets are consistent with the stated uncertainties. The fractional frequency uncertainties of some Cs fountains are now in the range of 4 × 10 −16 to 5 × 10 −16 . The results of this investigation show that the standards agree well with each other. An overall estimate of the caesium frequency is made using the weighted mean of all the fountains.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/47/1/001

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 76

Metadata

Authors
Parker, T. E.
Venue
Metrologia
Published
2009-12-07
Volume
47
Issue
1
Pages
1-10
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2128860535
Cited by
76
References
6
FWCI
5.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Long-term comparison of caesium fountain primary frequency standards. https://app.cochat.ai/papers/10.1088/0026-1394/47/1/001
The paper
Parker, T. E. (2010). Long-term comparison of caesium fountain primary frequency standards. Metrologia. https://doi.org/10.1088/0026-1394/47/1/001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.