Timescales at the BIPM
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
This paper reviews the present status of the timescales established at the International Bureau of Weights and Measures (BIPM). We focus our attention on the calculation and the characteristics of Coordinated Universal Time (UTC) and present its applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The atomic international time (TAI) is the most commonly used realization of TT [56, 124].”
From Chronometric Geodesy: Methods and Applications (2019) · cites this paper as [56]
Citations
Cites
Precise Point Positioning Using IGS Orbit and Clock Products
Kouba, J., & Héroux, P. (2001) · GPS Solutions · doi:10.1007/pl00012883 · Cited by 1,488
An Atomic Standard of Frequency and Time Interval: A Cæsium Resonator
ESSEN, L., & PARRY, J. V. L. (1955) · Nature · doi:10.1038/176280a0 · Cited by 305
Two-way time transfer via communication satellites
Kirchner, D. (1991) · Proceedings of the IEEE · doi:10.1109/5.84975 · Cited by 192 · cited 8×
“As of April 2011, 45% of the links in TAI/UTC are obtained using GPS single-frequency data, 37% from dualfrequency GPS receivers; most of the TWSTFT links are used in combination with GPS (PPP and P3), these totalling 12% of the time links.”
MethodInfluentialGPS All in View time transfer for TAI computation
Petit, G., & Jiang, Z. (2008) · Metrologia · doi:10.1088/0026-1394/45/1/006 · Cited by 148 · cited 2×
“Then advances in obtaining precise satellite orbits and clock parameters allowed the introduction of another technique, named All in View (AV) [19] that eliminates the constraint of having simultaneous observations, thus becoming independent of the length of the baseline for having suitable observed satellites.”
MethodSelf-citationTime transfer to TAI using geodetic receivers
Defraigne, P., & Petit, G. (2003) · Metrologia · doi:10.1088/0026-1394/40/4/307 · Cited by 126 · cited 1×
“The GPS links obtained using dual-frequency receivers, termed GPS P3 [20, 21], provide ionosphere-free data and allow clock comparisons with nanosecond statistical uncertainty or better.”
MethodSelf-citationBeiDou Navigation Satellite System and its time scales
Han, C., Yang, Y., & Cai, Z. (2011) · Metrologia · doi:10.1088/0026-1394/48/4/s13 · Cited by 126
Precise Point Positioning for TAI Computation
Petit, G., & Jiang, Z. (2008) · International Journal of Navigation and Observation · doi:10.1155/2008/562878 · Cited by 124 · cited 3×
“As of April 2011, 45% of the links in TAI/UTC are obtained using GPS single-frequency data, 37% from dualfrequency GPS receivers; most of the TWSTFT links are used in combination with GPS (PPP and P3), these totalling 12% of the time links.”
MethodSelf-citationComparative Study of Time Scale Algorithms
Tavella, P., & Thomas, C. (1991) · Metrologia · doi:10.1088/0026-1394/28/2/001 · Cited by 119
Fundamentals of two-way time transfers by satellite
Hanson, D. W. (2003) · Proceedings of the 43rd Annual Symposium on Frequency Control · doi:10.1109/freq.1989.68861 · Cited by 92 · cited 8×
“As of April 2011, 45% of the links in TAI/UTC are obtained using GPS single-frequency data, 37% from dualfrequency GPS receivers; most of the TWSTFT links are used in combination with GPS (PPP and P3), these totalling 12% of the time links.”
MethodInfluentialLong-term comparison of caesium fountain primary frequency standards
Parker, T. E. (2010) · Metrologia · doi:10.1088/0026-1394/47/1/001 · Cited by 76
Combination of TWSTFT and GNSS for accurate UTC time transfer
Jiang, Z., & Petit, G. (2009) · Metrologia · doi:10.1088/0026-1394/46/3/019 · Cited by 74 · cited 1×
“The combination of time links obtained from different techniques [35] allows us to make use of the redundancy of the time links network and combines the advantages of TWSTFT and GNSS carrier phase measurements.”
MethodSelf-citationEstimation of the Scale Unit Duration of Time Scales
Azoubib, J., Granveaud, M., & Guinot, B. (1977) · Metrologia · doi:10.1088/0026-1394/13/3/001 · Cited by 61
Electrical characterization of highly Titania doped YSZ
Kaiser, A., Feighery, A. J., Fagg, D. P., & Irvine, J. T. S. (1998) · Ionics · doi:10.1007/bf02375948 · Cited by 49
Use of GLONASS for UTC time transfer
Jiang, Z., & Lewandowski, W. (2011) · Metrologia · doi:10.1088/0026-1394/49/1/009 · Cited by 48 · cited 1×
“Studies on the possible causes of these biases [25] did not reach a clear conclusion, but showed that using the L1C code with the CV technique they are no larger than the measurement noise.”
MethodThe evaluation of uncertainties in [UTC−UTC(k)]
Lewandowski, W. W., Matsakis, D. N., Panfilo, G., & Tavella, P. (2006) · Metrologia · doi:10.1088/0026-1394/43/3/010 · Cited by 48
Self-citationTAI computation: study of an alternative choice for implementing an upper limit of clock weights
Thomas, C., & Azoubib, J. (1996) · Metrologia · doi:10.1088/0026-1394/33/3/5 · Cited by 42 · cited 1×
“• the weighting algorithm optimized to guarantee the longterm stability of TAI; the weight attributed to a clock reflects its long-term stability, since the objective is to obtain a weighted average that is more stable in the long term than any of the contributing elements [37, 38].”
BackgroundA New Realization of Terrestrial Time
Petit, G. (2003) · jsrs · Cited by 35
Self-citationSome Properties of Algorithms for Atomic Time Scales
Guinot, B. R. (1987) · Metrologia · doi:10.1088/0026-1394/24/4/007 · Cited by 32
Use of Geodetic Receivers for TAI
Defraigne, P., Petit, G., & Bruyninx, C. (2002) · Cited by 28
Self-citationEvolution of timescales from astronomy to physical metrology
McCarthy, D. D. (2011) · Metrologia · doi:10.1088/0026-1394/48/4/s03 · Cited by 15
Lewandowski, W. W., & Jiang, Z. (2009) · Cited by 13
Analysis of correlations, and link and equipment noise in the uncertainties of [UTC - UTC(k)]
Lewandowski, W. W., Matsakis, D. N., Panfilo, G., & Tavella, P. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.709 · Cited by 13 · cited 1×
“As from January 2005, the uncertainties of the differences are also published [49, 50].”
BackgroundSelf-citationATOMIC TIME SCALES TAI AND TT(BIPM): PRESENT STATUS AND PROSPECTS
Petit, G. (2009) · Symposium on Frequency Standards and Metrology · doi:10.1142/9789812838223_0060 · Cited by 11
Self-citationStudies and possible improvements on EAL algorithm
Panfilo, G., & Arias, E. F. (2009) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2009.5168152 · Cited by 11
Self-citationA time scale for satellite navigation systems: why and how?
Hahn, J., & Tavella, P. (2000) · International Journal of Satellite Communications · doi:10.1002/1099-1247(200007/10)18:4/5<305::aid-sat661>3.0.co;2-9 · Cited by 10
Calibration of the IEN-PTB TWSTFT link with a portable reference station
Cordara, F., Lorini, L., Pettiti, V., Tavella, P., Piester, D., Becker, J., Polewka, T., de Jong, G., Koudelka, O., Ressler, H., et al. (2004) · European Frequency and Time Forum · doi:10.1049/cp:20040833 · Cited by 9
Estimation of the duration of the scale unit of TAI with primary frequency standards
Arias, E. F., & Petit, G. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2005.1573936 · Cited by 6 · cited 1×
“Data from several PFS are combined to estimate the duration of the scale unit of TAI [41, 42].”
MethodSelf-citation
Cited by
The International Pulsar Timing Array
Manchester, R. N. (2013) · Classical and Quantum Gravity · doi:10.1088/0264-9381/30/22/224010 · Cited by 253
Development of a pulsar-based time-scale
Hobbs, G., Coles, W., Manchester, R. N., Keith, M. J., Shannon, R. M., Chen, D., Bailes, M., Bhat, N. D. R., Burke-Spolaor, S., Champion, D., et al. (2012) · Monthly Notices of the Royal Astronomical Society · doi:10.1111/j.1365-2966.2012.21946.x · Cited by 186
The Coordinated Universal Time (UTC)
Panfilo, G., & Arias, E. F. (2019) · Metrologia · doi:10.1088/1681-7575/ab1e68 · Cited by 157
Self-citationA pulsar-based time-scale from the International Pulsar Timing Array
Hobbs, G. B., Guo, L., Caballero, R. N., Coles, W. A., Lee, K., Manchester, R. N., Reardon, D. J., Matsakis, D. N., Tong, M., Arzoumanian, Z., et al. (2019) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stz3071 · Cited by 108
“To provide stability over years and decades TAI is ‘steered’ by comparison with ‘primary and secondary representations of the second’ (presently caesium and rubidium fountains respectively) to keep the TAI second as close as possible to the SI second (Arias et al. 2011).”
BackgroundGeneration of UTC(PTB) as a fountain-clock based time scale
Bauch, A., Weyers, S., Piester, D., Staliuniene, E., & Yang, W. (2012) · Metrologia · doi:10.1088/0026-1394/49/3/180 · Cited by 104
“The decision was made initially to always use d estimated for the previous month and published at the end of Section 4 of Circular T, irrespective of the fact that d depends in a complicated way on the past contributions of several primary frequency standards [5, 15], not always including CSF1.”
Method
Metadata
- Authors
- Arias, E. F., Panfilo, G., & Petit, G.
- Affiliations
- Observatoire de Paris (FR)
- Bureau international des poids et mesures (FR)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2011-07-20
- Volume
- 48
- Issue
- 4
- Pages
- S145-S153
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W1997891494
- Semantic Scholar
- caeb3b561463fad57af42196265df5fe253954e1
- Cited by
- 64
- References
- 28
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 5 · 2023: 5 · 2022: 4 · 2021: 4 · 2020: 2 · 2019: 7 · 2018: 2 · 2017: 10 · 2016: 6 · 2015: 4 · 2013: 3 · 2012: 6
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- HAL (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- time scales, Coordinated Universal Time, time and frequency metrology, BIPM
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.