Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 177

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Metrological characterization of the pulsed Rb clock with optical detection

Open access
Micalizio, S, Calosso, C E, Godone, A, Levi, F · 2012 · Metrologia

Abstract

We report on the implementation and the metrological characterization of a vapor-cell Rb frequency standard working in pulsed regime. The three main parts that compose the clock, physics package, optics and electronics, are described in detail in the paper. The prototype is designed and optimized to detect the clock transition in the optical domain. Specifically, the reference atomic transition, excited with a Ramsey scheme, is detected by observing the interference pattern on a laser absorption signal. \ The metrological analysis includes the observation and characterization of the clock signal and the measurement of frequency stability and drift. In terms of Allan deviation, the measured frequency stability results as low as $1.7\times 10^{-13} \ τ^{-1/2}$, $τ$ being the averaging time, and reaches the value of few units of $10^{-15}$ for $τ=10^{4}$ s, an unprecedent achievement for a vapor cell clock. We discuss in the paper the physical effects leading to this result with particular care to laser and microwave noises transferred to the clock signal. The frequency drift, probably related to the temperature, stays below $10^{-14}$ per day, and no evidence of flicker floor is observed. \ We also mention some possible improvements that in principle would lead to a clock stability below the $10^{-13}$ level at 1 s and to a drift of few units of $10^{-15}$ per day.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/49/4/425

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 177

Metadata

Authors
Micalizio, S., Calosso, C. E., Godone, A., & Levi, F.
Venue
Metrologia
Published
2012-05-16
Volume
49
Issue
4
Pages
425-436
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2019818641
Cited by
177
References
1
FWCI
6.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Metrological characterization of the pulsed Rb clock with optical detection. https://app.cochat.ai/papers/10.1088/0026-1394/49/4/425
The paper
Micalizio, S., Calosso, C. E., Godone, A., & Levi, F. (2012). Metrological characterization of the pulsed Rb clock with optical detection. Metrologia. https://doi.org/10.1088/0026-1394/49/4/425

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.