The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bayesian reconstruction of PET images: methodology and performance analysis
Open accessAbstract
We describe a practical statistical methodology for the reconstruction of PET images. Our approach is based on a Bayesian formulation of the imaging problem. The data are modelled as independent Poisson random variables and the image is modelled using a Markov random field smoothing prior. We describe a sequence of calibration procedures which are performed before reconstruction: (i) calculation of accurate attenuation correction factors from re-projected Bayesian reconstructions of the transmission image; (ii) estimation of the mean of the randoms component in the data; and (iii) computation of the scatter component in the data using a Klein-Nishina-based scatter estimation method. The Bayesian estimate of the PET image is then reconstructed using a pre-conditioned conjugate gradient method. We performed a quantitation study with a multi-compartment chest phantom in a Siemens/CTI ECAT931 system. Using 40 1 min frames, we computed the ensemble mean and variance over several regions of interest from images reconstructed using the Bayesian and a standard filtered backprojection (FBP) protocol. The values for the region of interest were compared with well counter data for each compartment. These results show that the Bayesian protocol can produce substantial improvements in relative quantitation over the standard FBP protocol, particularly when short transmission scans are used. An example showing the application of the method to a clinical chest study is also given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cited by
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/027 · Cited by 635
Self-citationMicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
Self-citationNew, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Self-citation
Metadata
- Authors
- Mumcuoglu, E. Ü., Leahy, R. M., & Cherry, S. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1996-09-01
- Volume
- 41
- Issue
- 9
- Pages
- 1777-1807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2052419043
- Cited by
- 214
- References
- 1
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bayesian reconstruction of PET images: methodology and performance analysis. https://app.cochat.ai/papers/10.1088/0031-9155/41/9/015
- The paper
- Mumcuoglu, E. Ü., Leahy, R. M., & Cherry, S. R. (1996). Bayesian reconstruction of PET images: methodology and performance analysis. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/41/9/015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.