MicroPET: a high resolution PET scanner for imaging small animals

Cherry, S.R., Shao, Y., Silverman, R.W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J.W., Jones, W., Moyers, J.C., Newport, D., Boutefnouchet, A., Farquhar, T.H., Andreaco, M., Paulus, M.J., Binkley, D.M., Nutt, R., Phelps, M.E.·1997·IEEE Transactions on Nuclear Science

Abstract

MicroPET is a high resolution positron emission tomography (PET) scanner designed for imaging small laboratory animals. It consists of a ring of 30 position-sensitive scintillation detectors, each with an 8/spl times/8 array of small lutetium oxyorthosilicate (LSO) crystals coupled via optical fibers to a multi-channel photomultiplier tube. The detectors have an intrinsic resolution averaging 1.68 mm, an energy resolution between 15 and 25% and 2.4 ns timing resolution at 511 keV. The detector ring diameter of microPET is 17.2 cm with an imaging field of view of 112 mm transaxially by 18 mm axially. The scanner has no septa and operates exclusively in 3D mode. Reconstructed image resolution 1 cm from the center of the scanner is 2.0 mm and virtually isotropic, yielding a volume resolution of 8 mm/sup 3/. For comparison, the volume resolution of state-of-the-art clinical PET systems is in the range of 50-75 mm/sup 3/. Initial images of phantoms have been acquired and are reported. A computer controlled bed is under construction and will incorporate a small wobble motion to improve spatial sampling. This is projected to further enhance spatial resolution. MicroPET is the first PET scanner to incorporate the new scintillator LSO and to our knowledge is the highest resolution multi-ring PET scanner currently in existence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/23.596981

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 609

Metadata

Authors
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., Boutefnouchet, A., Farquhar, T. H., Andreaco, M., Paulus, M. J., Binkley, D. M., Nutt, R., & Phelps, M. E.
Venue
IEEE Transactions on Nuclear Science
Published
1997-06
Volume
44
Issue
3
Pages
1161-1166
ISSN
  • 0018-9499 (ISSN-L)
  • 1558-1578
OpenAlex
W1990371352
Cited by
609
References
0
FWCI
30.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MicroPET: a high resolution PET scanner for imaging small animals. https://app.cochat.ai/papers/10.1109/23.596981
The paper
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., Boutefnouchet, A., Farquhar, T. H., Andreaco, M., Paulus, M. J., Binkley, D. M., Nutt, R., & Phelps, M. E. (1997). MicroPET: a high resolution PET scanner for imaging small animals. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.596981

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.