The DOI matches its Crossref record.
MicroPET: a high resolution PET scanner for imaging small animals
Abstract
MicroPET is a high resolution positron emission tomography (PET) scanner designed for imaging small laboratory animals. It consists of a ring of 30 position-sensitive scintillation detectors, each with an 8/spl times/8 array of small lutetium oxyorthosilicate (LSO) crystals coupled via optical fibers to a multi-channel photomultiplier tube. The detectors have an intrinsic resolution averaging 1.68 mm, an energy resolution between 15 and 25% and 2.4 ns timing resolution at 511 keV. The detector ring diameter of microPET is 17.2 cm with an imaging field of view of 112 mm transaxially by 18 mm axially. The scanner has no septa and operates exclusively in 3D mode. Reconstructed image resolution 1 cm from the center of the scanner is 2.0 mm and virtually isotropic, yielding a volume resolution of 8 mm/sup 3/. For comparison, the volume resolution of state-of-the-art clinical PET systems is in the range of 50-75 mm/sup 3/. Initial images of phantoms have been acquired and are reported. A computer controlled bed is under construction and will incorporate a small wobble motion to improve spatial sampling. This is projected to further enhance spatial resolution. MicroPET is the first PET scanner to incorporate the new scintillator LSO and to our knowledge is the highest resolution multi-ring PET scanner currently in existence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Multimodality Molecular Imaging of Tumor Angiogenesis
Cai, W., & Chen, X. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045922 · Cited by 494
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Self-citationGambhir, S. S., Barrio, J. R., Phelps, M. E., Iyer, M., Namavari, M., Satyamurthy, N., Wu, L., Green, L. A., Bauer, E., MacLaren, D. C., et al. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2333 · Cited by 450
Self-citationGambhir, S. S., Bauer, E., Black, M. E., Liang, Q., Kokoris, M. S., Barrio, J. R., Iyer, M., Namavari, M., Phelps, M. E., & Herschman, H. R. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.6.2785 · Cited by 450
Self-citation
Metadata
- Authors
- Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., Boutefnouchet, A., Farquhar, T. H., Andreaco, M., Paulus, M. J., Binkley, D. M., Nutt, R., & Phelps, M. E.
- Venue
- IEEE Transactions on Nuclear Science
- Published
- 1997-06
- Volume
- 44
- Issue
- 3
- Pages
- 1161-1166
- ISSN
- 0018-9499 (ISSN-L)
- 1558-1578
- OpenAlex
- W1990371352
- Cited by
- 609
- References
- 0
- FWCI
- 30.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MicroPET: a high resolution PET scanner for imaging small animals. https://app.cochat.ai/papers/10.1109/23.596981
- The paper
- Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., Boutefnouchet, A., Farquhar, T. H., Andreaco, M., Paulus, M. J., Binkley, D. M., Nutt, R., & Phelps, M. E. (1997). MicroPET: a high resolution PET scanner for imaging small animals. IEEE Transactions on Nuclear Science. https://doi.org/10.1109/23.596981
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.