Bayesian reconstruction of PET images: methodology and performance analysis
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We describe a practical statistical methodology for the reconstruction of PET images. Our approach is based on a Bayesian formulation of the imaging problem. The data are modelled as independent Poisson random variables and the image is modelled using a Markov random field smoothing prior. We describe a sequence of calibration procedures which are performed before reconstruction: (i) calculation of accurate attenuation correction factors from re-projected Bayesian reconstructions of the transmission image; (ii) estimation of the mean of the randoms component in the data; and (iii) computation of the scatter component in the data using a Klein-Nishina-based scatter estimation method. The Bayesian estimate of the PET image is then reconstructed using a pre-conditioned conjugate gradient method. We performed a quantitation study with a multi-compartment chest phantom in a Siemens/CTI ECAT931 system. Using 40 1 min frames, we computed the ensemble mean and variance over several regions of interest from images reconstructed using the Bayesian and a standard filtered backprojection (FBP) protocol. The values for the region of interest were compared with well counter data for each compartment. These results show that the Bayesian protocol can produce substantial improvements in relative quantitation over the standard FBP protocol, particularly when short transmission scans are used. An example showing the application of the method to a clinical chest study is also given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Photon mass attenuation and energy-absorption coefficients
Hubbell, J. H. (1982) · The International Journal of Applied Radiation and Isotopes · doi:10.1016/0020-708x(82)90248-4 · Cited by 1,459
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
A generalized Gaussian image model for edge-preserving MAP estimation
Bouman, C., & Sauer, K. (1993) · IEEE Transactions on Image Processing · doi:10.1109/83.236536 · Cited by 884
A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
Hebert, T., & Leahy, R. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24868 · Cited by 622
Self-citationPenalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Bergström, M., Eriksson, L., Bohm, C., Blomqvist, G., & Litton, J. (1983) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198302000-00008 · Cited by 388
On the Solution of Large Quadratic Programming Problems with Bound Constraints
Moré, J. J., & Toraldo, G. (1991) · SIAM Journal on Optimization · doi:10.1137/0801008 · Cited by 335
Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
Kaufman, L. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307796 · Cited by 293
Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images
Mumcuoglu, E. U., Leahy, R., Cherry, S. R., & Zhou, Z. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363099 · Cited by 282
Self-citation
Cited by
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/027 · Cited by 635
Self-citationMicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
Self-citationNew, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Self-citationNuyts, J., Dupont, P., Stroobants, S., Benninck, R., Mortelmans, L., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774167 · Cited by 362
Iterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291
Conjugate-gradient preconditioning methods for shift-variant PET image reconstruction
Fessler, J. A., & Booth, S. D. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.760336 · Cited by 236
“The remainder of this section reviews the PCG algorithm.”
BackgroundStatistical approaches in quantitative positron emission tomography
Leahy, R. M., & Qi, J. (2000) · Statistics and Computing · doi:10.1023/a:1008946426658 · Cited by 215
“Instead we have used Monte Carlo simulations in which we track large numbers of photon pairs through a simplified model of the detectors (Mumcuoglu et al. 1996).”
MethodSelf-citationLemmens, C., Faul, D., & Nuyts, J. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.929103 · Cited by 194
Fast EM-like methods for maximum "a posteriori" estimates in emission tomography
De Pierro, A. R., & Yamagishi, M. E. B. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.921477 · Cited by 181
“Others have considered preconditioned conjugate gradient techniques [26], [27], [32], [ 33 ].”
MethodFast reconstruction of 3D PET data with accurate statistical modeling
Comtat, C., Kinahan, P. E., Defrise, M., Michel, C., & Townsend, D. W. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.681983 · Cited by 165
Teoh, E. J., McGowan, D. R., Bradley, K. M., Belcher, E., Black, E., & Gleeson, F. V. (2016) · European Radiology · doi:10.1007/s00330-015-3832-y · Cited by 109
Influences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
Moving the goalposts while scoring―the dilemma posed by new PET technologies
Rogasch, J. M. M., Boellaard, R., Pike, L., Borchmann, P., Johnson, P., Wolf, J., Barrington, S. F., & Kobe, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05403-2 · Cited by 20
“PL reconstruction algorithms use the Bayesian principle by integrating estimates about the physical properties of the unknown image as a prior probability [34].”
Method
Metadata
- Authors
- Mumcuoglu, E. Ü., Leahy, R. M., & Cherry, S. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1996-09-01
- Volume
- 41
- Issue
- 9
- Pages
- 1777-1807
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2052419043
- Cited by
- 214
- References
- 19
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.