DPM, a fast, accurate Monte Carlo code optimized for photon and electron radiotherapy treatment planning dose calculations
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
A new Monte Carlo (MC) algorithm, the 'dose planning method' (DPM), and its associated computer program for simulating the transport of electrons and photons in radiotherapy class problems employing primary electron beams, is presented. DPM is intended to be a high accuracy MC alternative to the current generation of treatment planning codes which rely on analytical algorithms based on an approximate solution of the photon/electron Boltzmann transport equation. For primary electron beams, DPM is capable of computing 3D dose distributions (in 1 mm3 voxels) which agree to within 1% in dose maximum with widely used and exhaustively benchmarked general-purpose public-domain MC codes in only a fraction of the CPU time. A representative problem, the simulation of 1 million 10 MeV electrons impinging upon a water phantom of 128(3) voxels of 1 mm on a side, can be performed by DPM in roughly 3 min on a modern desktop workstation. DPM achieves this performance by employing transport mechanics and electron multiple scattering distribution functions which have been derived to permit long transport steps (of the order of 5 mm) which can cross heterogeneity boundaries. The underlying algorithm is a 'mixed' class simulation scheme, with differential cross sections for hard inelastic collisions and bremsstrahlung events described in an approximate manner to simplify their sampling. The continuous energy loss approximation is employed for energy losses below some predefined thresholds, and photon transport (including Compton, photoelectric absorption and pair production) is simulated in an analogue manner. The delta-scattering method (Woodcock tracking) is adopted to minimize the computational costs of transporting photons across voxels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MCNP-A General Monte Carlo N-Particle Transport Code
Briesmeister, J. F. (1993) · Cited by 5,110
The quantum theory of radiation
Mokhiemer, T. A. (1997) · International Journal of Quantum Chemistry · doi:10.1002/(sici)1097-461x(1997)64:6<735::aid-qua10>3.0.co;2-# · Cited by 2,909
Molière's Theory of Multiple Scattering
Bethe, H. A. (1953) · Physical Review · doi:10.1103/physrev.89.1256 · Cited by 889
Baró, J., Sempau, J., Fernández-Varea, J. M., & Salvat, F. (1995) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(95)00349-5 · Cited by 799
Self-citationMultiple Scattering of Electrons
Goudsmit, S., & Saunderson, J. L. (1940) · Physical Review · doi:10.1103/physrev.57.24 · Cited by 621
Multiple Scattering in an Infinite Medium
Lewis, H. W. (1950) · Physical Review · doi:10.1103/physrev.78.526 · Cited by 472
Bremsstrahlung spectra from electron interactions with screened atomic nuclei and orbital electrons
Seltzer, S. M., & Berger, M. J. (1985) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(85)90707-4 · Cited by 410
An algorithm for Monte Carlo simulation of coupled electron-photon transport
Sempau, J., Acosta, E., Baro, J., Fernández-Varea, J. M., & Salvat, F. (1997) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(97)00414-x · Cited by 391
Self-citation3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC)
Kawrakow, I., Fippel, M., & Friedrich, K. (1996) · Medical Physics · doi:10.1118/1.597673 · Cited by 322
Ribberfors, R. (1975) · Physical Review B · doi:10.1103/physrevb.12.2067 · Cited by 253
Electron-photon Monte Carlo calculations: The ETRAN code
Seltzer, S. M. (1991) · International Journal of Radiation Applications and Instrumentation Part A Applied Radiation and Isotopes · doi:10.1016/0883-2889(91)90050-b · Cited by 188
Monte Carlo Techniques of Electron and Photon Transport for Radiation Dosimetry
ROGERS, D. W. O., & BIELAJEW, A. F. (1990) · The Dosimetry of Ionizing Radiation · doi:10.1016/b978-0-12-400403-0.50009-9 · Cited by 170
Self-citationOn the theory and simulation of multiple elastic scattering of electrons
Fernández‐Varea, J. M., Mayol, R., Baró, J., & Salvat, F. (1993) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(93)95827-r · Cited by 149
Salvat, F., & Fernández‐Varea, J. M. (1992) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(92)95108-4 · Cited by 54
Lawrence Livermore National Laboratory`s PEREGRINE project
Siantar, C. L. H., Bergstrom, P. M., & Chandler, W. P. (1997) · University of North Texas Digital Library (University of North Texas) · Cited by 38
Cited by
Intensity-modulated radiotherapy: current status and issues of interest
(2001) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(01)01749-7 · Cited by 767
Badal, A., & Badano, A. (2009) · Medical Physics · doi:10.1118/1.3231824 · Cited by 358
Online Magnetic Resonance Image Guided Adaptive Radiation Therapy: First Clinical Applications
Acharya, S., Fischer-Valuck, B. W., Kashani, R., Parikh, P., Yang, D., Zhao, T., Green, O., Wooten, O., Li, H. H., Hu, Y., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.10.015 · Cited by 302
Sempau, J., Badal, A., & Brualla, L. (2011) · Medical Physics · doi:10.1118/1.3643029 · Cited by 277
Self-citationGPU-based fast Monte Carlo simulation for radiotherapy dose calculation
Jia, X., Gu, X., Graves, Y. J., Folkerts, M., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/22/002 · Cited by 185
“The original sequential DPM MC code was previously developed for fast dose calculations in radiotherapy treatment planning (Sempau et al., 2000).”
BackgroundMethod
Metadata
- Authors
- Sempau, J., Wilderman, S. J., & Bielajew, A. F.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-07-25
- Volume
- 45
- Issue
- 8
- Pages
- 2263-2291
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2023676835
- Cited by
- 321
- References
- 15
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.