Evaluation of inverse methods and head models for EEG source localization using a human skull phantom
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
We used a real-skull phantom head to investigate the performances of representative methods for EEG source localization when considering various head models. We describe several experiments using a montage with current sources located at multiple positions and orientations inside a human skull filled with a conductive medium. The robustness of selected methods based on distributed source models is evaluated as various solutions to the forward problem (from the sphere to the finite element method) are considered. Experimental results indicate that inverse methods using appropriate cortex-based source models are almost always able to locate the active source with excellent precision, with little or no spurious activity in close or distant regions, even when two sources are simultaneously active. Superior regularization schemes for solving the inverse problem can dramatically help the estimation of sparse and focal active zones, despite significant approximation of the head geometry and the conductivity properties of the head tissues. Realistic head models are necessary, though, to fit the data with a reasonable level of residual variance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
The organization of the cortical motor system: new concepts
Rizzolatti, G., Luppino, G., & Matelli, M. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00022-4 · Cited by 1,127
EEG and MEG: forward solutions for inverse methods
Mosher, J. C., Leahy, R. M., & Lewis, P. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748978 · Cited by 839 · cited 7×
“Thus, even models using the finite element method (FEM) approach with anisotropy parameters use average conductivity values that were measured on dead tissues (Rush and Driscoll 1968, Robillard and Poussart 1977). It is thus necessary for reliable localization of brain sources that inverse procedures are able to overc…”
BackgroundMethodInfluentialEvoked dipole source potentials of the human auditory cortex
Scherg, M., & Von Cramon, D. (1986) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(86)90014-6 · Cited by 707
Image reconstruction and restoration: overview of common estimation structures and problems
Demoment, G. (1989) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/29.45551 · Cited by 647
Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm
Gorodnitsky, I. F., George, J. S., & Rao, B. D. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00107-a · Cited by 567
Cited by
Parameterizing neural power spectra into periodic and aperiodic components
Donoghue, T., Haller, M., Peterson, E. J., Varma, P., Sebastian, P., Gao, R., Noto, T., Lara, A. H., Wallis, J. D., Knight, R. T., et al. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00744-x · Cited by 2,254
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
Self-citationEEG Source Imaging: A Practical Review of the Analysis Steps
Michel, C. M., & Brunet, D. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00325 · Cited by 705
EEG and MEG Data Analysis in SPM8
Litvak, V., Mattout, J., Kiebel, S., Phillips, C., Henson, R., Kilner, J., Barnes, G., Oostenveld, R., Daunizeau, J., Flandin, G., et al. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/852961 · Cited by 581
MEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
Functional coupling of simultaneous electrical and metabolic activity in the human brain
Oakes, T. R., Pizzagalli, D. A., Hendrick, A. M., Horras, K. A., Larson, C. L., Abercrombie, H. C., Schaefer, S. M., Koger, J. V., & Davidson, R. J. (2004) · Human Brain Mapping · doi:10.1002/hbm.20004 · Cited by 235
“There are multiple approaches to this problem [Baillet et al., 2001; Bosch-Bayard et al., 2001; Gorodnitsky et al., 1995]; based on previous work in our laboratory [e.”
BackgroundMethodInfluentialAsadzadeh, S., Yousefi Rezaii, T., Beheshti, S., Delpak, A., & Meshgini, S. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108740 · Cited by 174
“MEG can measure this magnetic field [1, 2].”
Spatially sparse source cluster modeling by compressive neuromagnetic tomography
Chang, W.-T., Nummenmaa, A., Hsieh, J.-C., & Lin, F.-H. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.013 · Cited by 52
“Different types of constraints have been proposed for the MEG/ EEG inverse problem, mainly motivated by computational tractability and/or physiological plausibility (Baillet et al., 2001; Hamalainen et al., 1993).”
Atypical auditory language processing in adolescents with autism spectrum disorder
Tanigawa, J., Kagitani-Shimono, K., Matsuzaki, J., Ogawa, R., Hanaie, R., Yamamoto, T., Tominaga, K., Nabatame, S., Mohri, I., Taniike, M., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.05.014 · Cited by 17
Metadata
- Authors
- Baillet, S., Riera, J. J., Marin, G., Mangin, J. F., Aubert, J., & Garnero, L.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2000-11-30
- Volume
- 46
- Issue
- 1
- Pages
- 77-96
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2066937230
- Cited by
- 159
- References
- 45
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.