Performance evaluation of the microPET P4: a PET system dedicated to animal imaging
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
The microPET Primate 4-ring system (P4) is an animal PET tomograph with a 7.8 cm axial extent, a 19 cm diameter transaxial field of view (FOV) and a 22 cm animal port. The system is composed of 168 detector modules, each with an 8 x 8 array of 2.2 x 2.2 x 10 mm3 lutetium oxyorthosilicate crystals, arranged as 32 crystal rings 26 cm in diameter. The detector crystals are coupled to a Hamamatsu R5900-C8 PS-PMT via a 10 cm long optical fibre bundle. The detectors have a timing resolution of 3.2 ns, an average energy resolution of 26%, and an average intrinsic spatial resolution of 1.75 mm. The system operates in 3D mode without inter-plane septa, acquiring data in list mode. The reconstructed image spatial resolution ranges from 1.8 mm at the centre to 3 mm at 4 cm radial offset. The tomograph has a peak system sensitivity of 2.25% at the centre of the FOV with a 250-750 keV energy window. The noise equivalent count rate peaks at 100-290 kcps for representative object sizes. Images from two phantoms and three different types of laboratory animal demonstrate the advantage of the P4 system over the original prototype microPET. including its threefold improvement in sensitivity and a large axial FOV sufficient to image an entire mouse in a single bed position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Self-citationHigh-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/027 · Cited by 635
Self-citationMicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
Self-citationStrother, S. C., Casey, M. E., & Hoffman, E. J. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106715 · Cited by 549
PET: the merging of biology and imaging into molecular imaging.
Phelps, M. E. (2000) · PubMed · Cited by 531
Imaging Transgene Expression with Radionuclide Imaging Technologies
Gambhir, S. S., Herschman, H. R., Cherry, S. R., Barrio, J. R., Satyamurthy, N., Toyokuni, T., Phelps, M. E., Larson, S. M., Balatoni, J., Finn, R., et al. (2000) · Neoplasia · doi:10.1038/sj.neo.7900083 · Cited by 358
Self-citationTreatment of axial data in three-dimensional PET.
Daube-Witherspoon, M. E., & Muehllehner, G. (1987) · PubMed · Cited by 357
Chatziioannou, A. F., Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Farquhar, T. H., Pedarsani, M., & Phelps, M. E. (1999) · PubMed · Cited by 347
Self-citationIn Vivo Transchelation of Copper-64 from TETA-Octreotide to Superoxide Dismutase in Rat Liver
Bass, L. A., Wang, M., Welch, M. J., & Anderson, C. J. (2000) · Bioconjugate Chemistry · doi:10.1021/bc990167l · Cited by 311
A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals
Jeavons, A. P., Chandler, R. A., & Dettmar, C. A. R. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775564 · Cited by 259
A high resolution animal PET scanner using compact PS-PMT detectors
Watanabe, M., Okada, H., Shimizu, K., Omura, T., Yoshikawa, E., Kosugi, T., Mori, S., & Yamashita, T. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.597001 · Cited by 241
Quantification of target gene expression by imaging reporter gene expression in living animals
Yu, Y., Annala, A. J., Barrio, J. R., Toyokuni, T., Satyamurthy, N., Namavari, M., Cherry, S. R., Phelps, M. E., Herschman, H. R., & Gambhir, S. S. (2000) · Nature Medicine · doi:10.1038/78704 · Cited by 223
Self-citationWu, A. M., Yazaki, P. J., Tsai, S.-W., Nguyen, K., Anderson, A.-L., McCarthy, D. W., Welch, M. J., Shively, J. E., Williams, L. E., Raubitschek, A. A., et al. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.150228297 · Cited by 214
Kornblum, H. I., Araujo, D. M., Annala, A. J., Tatsukawa, K. J., Phelps, M. E., & Cherry, S. R. (2000) · Nature Biotechnology · doi:10.1038/76509 · Cited by 192
Self-citationQuantitative imaging of iodine-124 with PET.
Pentlow, K. S., Graham, M. C., Lambrecht, R. M., Daghighian, F., Bacharach, S. L., Bendriem, B., Finn, R. D., Jordan, K. M., Kalaigian, H., Karp, J. S., et al. (1996) · PubMed · Cited by 172
Moore, A. H., Osteen, C. L., Chatziioannou, A. F., Hovda, D. A., & Cherry, S. R. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200010000-00011 · Cited by 141
Self-citationYAP-PET: first results of a small animal positron emission tomograph based on YAP:Ce finger crystals
Guerra, A. D., Domenico, G. D., Scandola, M., & Zavattini, G. (1998) · IEEE Transactions on Nuclear Science · doi:10.1109/23.737671 · Cited by 96
Three-dimensional performance of a small-diameter positron emission tomograph
Bloomfield, P., Myers, R., Hume, S. P., Spinks, T. J., Lammertsma, A. A., & Jones, T. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/2/010 · Cited by 60
Recent results of the TierPET scanner
Weber, S., Bauer, A., Herzog, H. R., Kehren, F., Mühlensiepen, H., Vogelbruch, J. F., Coenen, H. H., Zilles, K., & Halling, H. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873032 · Cited by 24
Cited by
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Self-citationAlexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/021 · Cited by 465
Self-citation(2005) · PubMed · Cited by 395
Jong, H. W. A. M. D., Velden, F. H. P. V., Kloet, R. W., Buijs, F. L., Boellaard, R., & Lammertsma, A. A. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/5/019 · Cited by 349
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Self-citation
Metadata
- Authors
- Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-06-21
- Volume
- 46
- Issue
- 7
- Pages
- 1845-1862
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2160463229
- Cited by
- 308
- References
- 19
- FWCI
- 25.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.