The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Label-free bioaffinity detection using terahertz technology
Abstract
We report the first use of differential terahertz time-domain spectroscopy for bioaffinity sensing. Binding is observed by measuring the transmission of a thin layer of biotin bound to the sensor protein avidin. We demonstrate the THz wave transmission of a sub-micron-thick film and sensitivity to 0.1 microg cm(-2) of biotin. These results point the way for a host of biosensor applications using T-rays, or pulsed far-infrared (FIR) radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239 · cited 1×
“Here we report for the first time an experimental investigation of the surface recognition process of the highly specific labelfree biotin–avidin complex, monitored with terahertz time-domain spectroscopy (THz-TDS) ( Grischkowsky et al 1990 ).”
MethodDielectric constant measurement of thin films by differential time-domain spectroscopy
Jiang, Z., Li, M., & Zhang, X.-C. (2000) · Applied Physics Letters · doi:10.1063/1.126587 · Cited by 139
Self-citation
Cited by
Materials for terahertz science and technology
Ferguson, B., & Zhang, X.-C. (2002) · Nature Materials · doi:10.1038/nmat708 · Cited by 3,284
Self-citationTerahertz Technology in Biology and Medicine
Siegel, P. H. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.835916 · Cited by 1,378
Biomedical applications of terahertz technology
Pickwell, E., & Wallace, V. P. (2006) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/39/17/r01 · Cited by 925
Metamaterials Application in Sensing
Chen, T., Li, S., & Sun, H. (2012) · Sensors · doi:10.3390/s120302742 · Cited by 557
Mechanisms and applications of terahertz metamaterial sensing: a review
Xu, W., Xie, L., & Ying, Y. (2017) · Nanoscale · doi:10.1039/c7nr03824k · Cited by 458
Detection of microorganisms using terahertz metamaterials
Park, S. J., Hong, J. T., Choi, S. J., Kim, H. S., Park, W. K., Han, S. T., Park, J. Y., Lee, S., Kim, D. S., & Ahn, Y. H. (2014) · Scientific Reports · doi:10.1038/srep04988 · Cited by 406
A Comprehensive Review on Food Applications of Terahertz Spectroscopy and Imaging
Afsah‐Hejri, L., Hajeb, P., Ara, P., & Ehsani, R. J. (2019) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12490 · Cited by 311
Frequency selective surfaces for high sensitivity terahertz sensing
Debus, C., & Bolivar, P. H. (2007) · Applied Physics Letters · doi:10.1063/1.2805016 · Cited by 301
Geng, Z., Zhang, X., Fan, Z., Lv, X., & Chen, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-16762-y · Cited by 289
Self-citationWithayachumnankul, W., Png, G. M., Yin, X., Atakaramians, S., Jones, I., Lin, H., Ung, B. S. Y., Balakrishnan, J., Ng, B. W.-H., Ferguson, B., et al. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.900325 · Cited by 179
Self-citationThe Application of Terahertz Spectroscopy to Protein Detection: A Review
Xie, L., Yao, Y., & Ying, Y. (2014) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2013.847845 · Cited by 137
Mickan, S. P., Shvartsman, R., Munch, J., Zhang, X.-C., & Abbott, D. (2004) · Journal of Optics B: Quantum and Semiclassical Optics · doi:10.1088/1464-4266/6/8/025 · Cited by 36
“T-rays have a wide range of applications from biosensing [5] through to use in quantum computers [6].”
BackgroundMethodSelf-citation
Metadata
- Authors
- Mickan, S. P., Menikh, A., Liu, H., Mannella, C. A., MacColl, R., Abbott, D., Munch, J., & Zhang, X.-C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2002-10-16
- Volume
- 47
- Issue
- 21
- Pages
- 3789-3795
- ISSN
- 0031-9155 (ISSN-L)
- OpenAlex
- W2098553180
- Cited by
- 162
- References
- 2
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.