Can the cerebral metabolic rate of oxygen be estimated with near-infrared spectroscopy?
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We have measured the changes in oxy-haemoglobin and deoxy-haemoglobin in the adult human brain during a brief finger tapping exercise using near-infrared spectroscopy (NIRS). The cerebral metabolic rate of oxygen (CMRO2) can be estimated from these NIRS data provided certain model assumptions. The change in CMRO2 is related to changes in the total haemoglobin concentration, deoxy-haemoglobin concentration and blood flow. As NIRS does not provide a measure of dynamic changes in blood flow during brain activation, we relied on a Windkessel model that relates dynamic blood volume and flow changes, which has been used previously for estimating CMRO2 from functional magnetic resonance imaging (fMRI) data. Because of the partial volume effect we are unable to quantify the absolute changes in the local brain haemoglobin concentrations with NIRS and thus are unable to obtain an estimate of the absolute CMRO2 change. An absolute estimate is also confounded by uncertainty in the flow-volume relationship. However, the ratio of the flow change to the CMRO2 change is relatively insensitive to these uncertainties. For the linger tapping task, we estimate a most probable flow-consumption ratio ranging from 1.5 to 3 in agreement with previous findings presented in the literature, although we cannot exclude the possibility that there is no CMRO2 change. The large range in the ratio arises from the large number of model parameters that must be estimated from the data. A more precise estimate of the flow-consumption ratio will require better estimates of the model parameters or flow information, as can be provided by combining NIRS with fMRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
NIRS-SPM: Statistical parametric mapping for near-infrared spectroscopy
YE, J., TAK, S., JANG, K., JUNG, J., & JANG, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.036 · Cited by 1,180
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
A quantitative comparison of NIRS and fMRI across multiple cognitive tasks
Cui, X., Bray, S., Bryant, D. M., Glover, G. H., & Reiss, A. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.069 · Cited by 945
Cui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Boas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Self-citationProspects of photoacoustic tomography
Wang, L. V. (2008) · Medical Physics · doi:10.1118/1.3013698 · Cited by 561
Optical brain imaging in vivo: techniques and applications from animal to man
Hillman, E. M. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2789693 · Cited by 436
Near-infrared spectroscopy: A report from the McDonnell infant methodology consortium
Gervain, J., Mehler, J., Werker, J. F., Nelson, C. A., Csibra, G., Lloyd-Fox, S., Shukla, M., & Aslin, R. N. (2011) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2010.07.004 · Cited by 363
Durduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Illuminating the BOLD signal: combined fMRI–fNIRS studies
Steinbrink, J., Villringer, A., Kempf, F., Haux, D., Boden, S., & Obrig, H. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.034 · Cited by 334
Label-free oxygen-metabolic photoacoustic microscopy in vivo
Yao, J., Maslov, K. I., Zhang, Y., Xia, Y., & Wang, L. V. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3594786 · Cited by 333
Plichta, M. M., Heinzel, S., Ehlis, A.-C., Pauli, P., & Fallgatter, A. J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.028 · Cited by 281
Tsuzuki, D., & Dan, I. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.07.025 · Cited by 265
Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients?
Crookes, B. A., Cohn, S. M., Bloch, S., Amortegui, J., Manning, R., Li, P., Proctor, M. S., Hallal, A., Blackbourne, L. H., Benjamin, R., et al. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000158269.68409.1c · Cited by 211
Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/009 · Cited by 164
“There exist a number of models for approximating the CBF, CBV and CMRO2 from fNIRS measurements (Wyatt et al 1990, Boas et al 2003).”
MethodThe potential of infant fMRI research and the study of early life stress as a promising exemplar
Graham, A. M., Pfeifer, J. H., Fisher, P. A., Lin, W., Gao, W., & Fair, D. A. (2015) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2014.09.005 · Cited by 114
“In addition, fNIRS facilitates xamining aspects of brain metabolism that are not posible to differentiate with fMRI (Boas et al., 2003; Dunn t al., 2003).”
Yücel, M. A., Selb, J., Boas, D. A., Cash, S. S., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.054 · Cited by 86
“The flow–consumption ratio is a relatively robust measure of neurovascular coupling (Boas et al., 2003).”
InfluentialSelf-citationTransverse flow imaging based on photoacoustic Doppler bandwidth broadening
Yao, J., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3339953 · Cited by 75
“Compared to other PA flow measurement methods, the method proposed here has the potential to retain the methods for measuring volumetric structure and oxygen saturation in the same system, which will provide a promising tool to measure the oxygen metabolism rate.(30)”
Method
Metadata
- Authors
- Boas, D. A., Strangman, G., Culver, J. P., Hoge, R. D., Jasdzewski, G., Poldrack, R. A., Rosen, B. R., & Mandeville, J. B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2003-07-22
- Volume
- 48
- Issue
- 15
- Pages
- 2405-2418
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2115387726
- Cited by
- 175
- References
- 3
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.