Integrating a MRI scanner with a 6 MV radiotherapy accelerator: dose deposition in a transverse magnetic field
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Integrating magnetic resonance imaging (MRI) functionality with a radiotherapy accelerator can facilitate on-line, soft-tissue based, position verification. A technical feasibility study, in collaboration with Elekta Oncology Systems and Philips Medical Systems, led to the preliminary design specifications of a MRI accelerator. Basically the design is a 6 MV accelerator rotating around a 1.5 T MRI system. Several technical issues and the clinical rational are currently under investigation. The aim of this paper is to determine the impact of the transverse 1.5 T magnetic field on the dose deposition. Monte Carlo simulations were used to calculate the dose deposition kernel in the presence of 1.5 T. This kernel in turn was used to determine the dose deposition for larger fields. Also simulations and measurements were done in the presence of 1.1 T. The pencil beam dose deposition is asymmetric. For larger fields the asymmetry persists but decreases. For the latter the distance to dose maximum is reduced by approximately 5 mm, the penumbra is increased by approximately 1 mm, and the 50% isodose line is shifted approximately 1 mm. The dose deposition in the presence of 1.5 T is affected, but the effect can be taken into account in a conventional treatment planning procedure. The impact of the altered dose deposition for clinical IMRT treatments is the topic of further research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
MCNP-A General Monte Carlo N-Particle Transport Code
Briesmeister, J. F. (1993) · Cited by 5,110
van Herk, M., Remeijer, P., Rasch, C., & Lebesque, J. V. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00518-6 · Cited by 1,531
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
Rogers, D. W. O., Faddegon, B. A., Ding, G. X., Ma, C. ‐., We, J., & Mackie, T. R. (1995) · Medical Physics · doi:10.1118/1.597552 · Cited by 1,431
Flat-panel cone-beam computed tomography for image-guided radiation therapy
Jaffray, D. A., Siewerdsen, J. H., Wong, J. W., & Martinez, A. A. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02884-5 · Cited by 1,330
Kawrakow, I. (2000) · Medical Physics · doi:10.1118/1.598917 · Cited by 945
Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality
Ling, C. C., Humm, J., Larson, S., Amols, H., Fuks, Z., Leibel, S., & Koutcher, J. A. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00467-3 · Cited by 926
Shirato, H., Shimizu, S., Kitamura, K., Nishioka, T., Kagei, K., Hashimoto, S., Aoyama, H., Kunieda, T., Shinohara, N., Dosaka-Akita, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00625-8 · Cited by 464
Wyckoff, H. O. (1974) · American Journal of Roentgenology · doi:10.2214/ajr.120.3.708 · Cited by 354
Megavoltage CT on a tomotherapy system
Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/10/316 · Cited by 261
Gilhuijs, K. G. A., van de Ven, P. J. H., & van Herk, M. (1996) · Medical Physics · doi:10.1118/1.597801 · Cited by 142
Cited by
The ViewRay System: Magnetic Resonance–Guided and Controlled Radiotherapy
Mutic, S., & Dempsey, J. F. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.008 · Cited by 915
Lagendijk, J. J. W., Raaymakers, B. W., Raaijmakers, A. J. E., Overweg, J., Brown, K. J., Kerkhof, E. M., van der Put, R. W., Hårdemark, B., van Vulpen, M., & van der Heide, U. A. (2008) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2007.10.034 · Cited by 511
Self-citationThe Magnetic Resonance Imaging–Linac System
Lagendijk, J. J. W., Raaymakers, B. W., & van Vulpen, M. (2014) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2014.02.009 · Cited by 464
Self-citationAdvances in Image-Guided Radiation Therapy
Dawson, L. A., & Jaffray, D. A. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.9515 · Cited by 420
Online Adaptive Radiation Therapy
Lim-Reinders, S., Keller, B. M., Al-Ward, S., Sahgal, A., & Kim, A. (2017) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.04.023 · Cited by 267
Metadata
- Authors
- Raaymakers, B. W., Raaijmakers, A. J. E., Kotte, A. N. T. J., Jette, D., & Lagendijk, J. J. W.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2004-08-20
- Volume
- 49
- Issue
- 17
- Pages
- 4109-4118
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2075601151
- Cited by
- 253
- References
- 11
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.