CoChat

A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms

DeMarco, J J, Cagnon, C H, Cody, D D, Stevens, D M, McCollough, C H, O'Daniel, J, McNitt-Gray, M F · 2005 · Physics in Medicine and Biology
Cited by 161

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

The purpose of this work was to extend the verification of Monte Carlo based methods for estimating radiation dose in computed tomography (CT) exams beyond a single CT scanner to a multidetector CT (MDCT) scanner, and from cylindrical CTDI phantom measurements to both cylindrical and physical anthropomorphic phantoms. Both cylindrical and physical anthropomorphic phantoms were scanned on an MDCT under the specified conditions. A pencil ionization chamber was used to record exposure for the cylindrical phantom, while MOSFET (metal oxide semiconductor field effect transistor) detectors were used to record exposure at the surface of the anthropomorphic phantom. Reference measurements were made in air at isocentre using the pencil ionization chamber under the specified conditions. Detailed Monte Carlo models were developed for the MDCT scanner to describe the x-ray source (spectra, bowtie filter, etc) and geometry factors (distance from focal spot to isocentre, source movement due to axial or helical scanning, etc). Models for the cylindrical (CTDI) phantoms were available from the previous work. For the anthropomorphic phantom, CT image data were used to create a detailed voxelized model of the phantom's geometry. Anthropomorphic phantom material compositions were provided by the manufacturer. A simulation of the physical scan was performed using the mathematical models of the scanner, phantom and specified scan parameters. Tallies were recorded at specific voxel locations corresponding to the MOSFET physical measurements. Simulations of air scans were performed to obtain normalization factors to convert results to absolute dose values. For the CTDI body (32 cm) phantom, measurements and simulation results agreed to within 3.5% across all conditions. For the anthropomorphic phantom, measured surface dose values from a contiguous axial scan showed significant variation and ranged from 8 mGy/100 mAs to 16 mGy/100 mAs. Results from helical scans of overlapping pitch (0.9375) and extended pitch (1.375) were also obtained. Comparisons between the MOSFET measurements and the absolute dose value derived from the Monte Carlo simulations demonstrate agreement in terms of absolute dose values as well as the spatially varying characteristics. This work demonstrates the ability to extend models from a single detector scanner using cylindrical phantoms to an MDCT scanner using both cylindrical and anthropomorphic phantoms. Future work will be extended to voxelized patient models of different sizes and to other MDCT scanners.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/50/17/005

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 161

Metadata

Authors
DeMarco, J. J., Cagnon, C. H., Cody, D. D., Stevens, D. M., McCollough, C. H., O'Daniel, J., & McNitt-Gray, M. F.
Venue
Physics in Medicine and Biology
Published
2005-08-11
Volume
50
Issue
17
Pages
3989-4004
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2076256307
Cited by
161
References
18
FWCI
4.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.