Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
We propose and characterize oil-in-gelatin dispersions that approximate the dispersive dielectric properties of a variety of human soft tissues over the microwave frequency range from 500 MHz to 20 GHz. Different tissues are mimicked by selection of an appropriate concentration of oil. The materials possess long-term stability and can be employed in heterogeneous configurations without change in geometry or dielectric properties due to osmotic effects. Thus, these materials can be used to construct heterogeneous phantoms, including anthropomorphic types, for narrowband and ultrawideband microwave technologies, such as breast cancer detection and imaging systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 7×
“…their dielectric properties and the dielectric properties of biological tissues of varying water contents, which are summarized and parametrized by Gabriel et al (1996) using a four-pole Cole-Cole model: In this equation, ˆ (ω) is the complex relative permittivity expressed as a function of…”
InfluentialGuy, A. W. (1971) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1968.1127484 · Cited by 454
Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging
Surry, K. J. M., Austin, H. J. B., Fenster, A., & Peters, T. M. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/24/009 · Cited by 356
Formulas for preparing phantom muscle tissue at various radiofrequencies
Chou, C., Chen, G., Guy, A. W., & Luk, K. H. (1984) · Bioelectromagnetics · doi:10.1002/bem.2250050408 · Cited by 253
Development and characteristics of a biological tissue-equivalent phantom for microwaves
Ito, K., Furuya, K., Okano, Y., & Hamada, L. (2001) · Electronics and Communications in Japan (Part I: Communications) · doi:10.1002/1520-6424(200104)84:4<67::aid-ecja8>3.0.co;2-d · Cited by 187
The Polyacrylamide as a Phantom Material for Electromagnetic Hyperthermia Studies
Bini, M., Ignesti, A., Millanta, L. M., Olmi, R., Rubino, N., & Vanni, R. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325271 · Cited by 118
Use of polyacrylamide as a tissue-equivalent material in the microwave range
Andreuccetti, D., Bini, M., Ignesti, A., Olmi, R., Rubino, N., & Vanni, R. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1377 · Cited by 79
Soft and dry phantom modeling material using silicone rubber with carbon fiber
Nikawa, Y., Chino, M., & Kikuchi, K. (1996) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.539954 · Cited by 74
New materials for dielectric simulation of tissues
Robinson, M. P., Richardson, M. J., Green, J., & Preece, A. (1991) · Physics in Medicine and Biology · doi:10.1088/0031-9155/36/12/002 · Cited by 57
Lagendijk, J. J. W., & Nilsson, P. G. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/7/011 · Cited by 49
Development of a dielectric equivalent gel for better impedance matching for human skin
Sunaga, T., Ikehira, H., Furukawa, S., Tamura, M., Yoshitome, E., Obata, T., Shinkai, H., Tanada, S., Murata, H., & Sasaki, Y. (2003) · Bioelectromagnetics · doi:10.1002/bem.10080 · Cited by 44
Cheung, A. Y., & Koopman, D. W. (1976) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1976.1128936 · Cited by 37
Cited by
Karacolak, T., Hood, A. Z., & Topsakal, E. (2008) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2008.919373 · Cited by 633
Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
Yilmaz, T., Foster, R., & Hao, Y. (2019) · Diagnostics · doi:10.3390/diagnostics9010006 · Cited by 192
“Oil-in-gelatine dispersion phantoms are used in the literature to imitate the dielectric properties of all biological tissues [27].”
BackgroundYilmaz, T., Foster, R., & Hao, Y. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2313139 · Cited by 168
Kandadai, M. A., Raymond, J. L., & Shaw, G. J. (2012) · Materials Science and Engineering: C · doi:10.1016/j.msec.2012.07.024 · Cited by 102
Multi-disciplinary challenges in tissue modeling for wireless electromagnetic powering: a review
Bocan, K. N., Mickle, M. H., & Sejdic, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2748338 · Cited by 41
“[18] reviewed gel phantom formulations along with their valid frequency ranges,”
Background
Metadata
- Authors
- Lazebnik, M., Madsen, E. L., Frank, G. R., & Hagness, S. C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-08-31
- Volume
- 50
- Issue
- 18
- Pages
- 4245-4258
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2106874336
- Cited by
- 418
- References
- 12
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.