Characterization of optical parameters with a human forearm at the region from 1.15 to 1.52 µm using diffuse reflectance measurements
Open accessAbstract
Time- and space-resolved diffuse reflectance measurements were used to identify the optical parameters, the reduced scattering and absorption coefficients, of bulk living tissue in the region from 1.15 to 1.52 microm. Although in this region the detector was limited in its temporal resolution, we applied a peak-time shift analysis successfully to determine these coefficients in a human forearm, and then determined the absorption spectrum by space-resolved diffuse reflectance measurements. The absorption spectrum of a water content of 52% determined by magnetic resonance imaging experiments is in good agreement with the absorption coefficient obtained by optical measurements. Moreover, magnetic resonance imaging measurements suggest that the deviation of the absorption coefficients from the water spectrum in the strong water absorption band is caused by the heterogeneity of water distribution in tissue: the low content of water in the skin. These findings indicate that this optical method is potentially applicable to the non-invasive measurement of water in tissue, especially in a region lower than about 1.3-1.35 microm, which may be useful in monitoring oedema and tissue swelling.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Penetration depth is less than 1 mm in the 1400 nm water absorption band.
“They found that the penetration depth is less than 1 mm in the 1400 nm water absorption band”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [55]
Penetration depth of optical measurements changes significantly at wavelengths corresponding with strong water absorption at longer wavelengths.
“Nishimura et al.55 described how the penetration depth of optical measurements changes significantly at wavelengths corresponding with strong water absorption at longer wavelengths.”
From Effect of skin color on optical properties and the implications for medical optical technologies: a review (2024) · cites this paper as [55]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
In vivo cancer targeting and imaging with semiconductor quantum dots
Gao, X., Cui, Y., Levenson, R. M., Chung, L. W. K., & Nie, S. (2004) · Nature Biotechnology · doi:10.1038/nbt994 · Cited by 4,775 · see citing works
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,479 · see citing works
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899 · see citing works
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,902 · see citing works
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720 · see citing works
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,621 · see citing works
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,143 · see citing works
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,121 · see citing works
Optical properties of circulating human blood in the wavelength range 400-2500 nm
Roggan, A., Friebel, M. F., Dörschel, K., Hahn, A., & Müller, G. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429919 · Cited by 823 · see citing works
Prasad, P. N. (2003) · Wiley eBooks · doi:10.1002/0471465380 · Cited by 653 · see citing works
Selection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/153535003765276282 · Cited by 559 · see citing works
Kienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474 · see citing works
Book Review: Introduction to Biophotonics
Masters, B. R. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1931672 · Cited by 442 · see citing works
Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm
Troy, T. L., & Thennadil, S. N. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1344191 · Cited by 420 · see citing works
Doornbos, R. M. P., Lang, R., Aalders, M. C., Cross, F. W., & Sterenborg, H. J. C. M. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/4/012 · Cited by 380 · see citing works
Srinivasan, S., Pogue, B. W., Jiang, S., Dehghani, H., Kogel, C. A., Soho, S. K., Gibson, J. J., Tosteson, T. D., Poplack, S. P., & Paulsen, K. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2032822100 · Cited by 267 · see citing works
Matcher, S. J., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000386 · Cited by 221 · see citing works
Torricelli, A. M., Pifferi, A., Taroni, P., Giambattistelli, E., & Cubeddu, R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/313 · Cited by 172 · see citing works
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172 · see citing works
van Veen, R. L. P., Sterenborg, H. J. C. M., Pifferi, A., Torricelli, A. M., & Cubeddu, R. (2004) · Biomedical Topical Meeting · doi:10.1364/bio.2004.sf4 · Cited by 159 · see citing works
Patterson, M. S., Andersson‐Engels, S., Wilson, B. C., et al. (1995) · Applied Optics · doi:10.1364/ao.34.000022 · Cited by 153 · see citing works
Noninvasive blood glucose assay using a newly developed near-infrared system
Maruo, K., Tsurugi, M., Chin, J., Ota, T., Arimoto, H., Yamada, Y., Tamura, M., Ishii, M., & Ozaki, Y. (2003) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2003.811283 · Cited by 147 · see citing works
Self-citationSpatial variations in optical and physiological properties of healthy breast tissue
Shah, N. S., Cerussi, A. E., Jakubowski, D. B., Hsiang, D. J. B., Butler, J., & Tromberg, B. J. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1695560 · Cited by 124 · see citing works
Amerov, A. K., Chen, J., & Arnold, M. A. (2004) · Applied Spectroscopy · doi:10.1366/0003702042336136 · Cited by 124 · see citing works
Photon diffusion coefficient in an absorbing medium
Aronson, R., & Corngold, N. R. (1999) · Journal of the Optical Society of America A · doi:10.1364/josaa.16.001066 · Cited by 102 · see citing works
Pifferi, A., Swartling, J., Chikoidze, E., Torricelli, A. M., Taroni, P., Bassi, A. L., Andersson‐Engels, S., & Cubeddu, R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1802171 · Cited by 96 · see citing works
Myoglobin ; biochemical, physiological, and clinical aspects
Kagen, L. J. (1973) · Columbia University Press eBooks · Cited by 87 · see citing works
The scanning laser ophthalmoscope—a review of its role in bioscience and medicine
Sharp, P. F., Manivannan, A., Xu, H., & Forrester, J. V. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/7/001 · Cited by 82 · see citing works
Chance, B. (1989) · Springer eBooks · doi:10.1007/978-1-4757-6178-8 · Cited by 81 · see citing works
Nomura, Y., & Tamura, M. (1991) · The Journal of Biochemistry · doi:10.1093/oxfordjournals.jbchem.a123403 · Cited by 41 · see citing works
Self-citationBoas, D. A., & Frostig, R. D. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1851511 · Cited by 13 · see citing works
Intrinsic Fluorescence Spectroscopy of Biological Tissue
Georgakoudi, I., Feld, M. S., & Müller, M. G. (2003) · CRC Press eBooks · doi:10.1201/9780203912096-4 · Cited by 10 · see citing works
Simple peak shift analysis of time-of-flight data with a slow instrumental response function
Nishimura, G., & Tamura, M. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1854684 · Cited by 8 · see citing works
Self-citationSpecial Section Guest Editorial: Optics in Breast Cancer
Fantini, S., Pogue, B. W., & Moesta, K. T. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1813446 · Cited by 5 · see citing works
Recent developments in biomedical optics
Wang, R. K. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/7/e01 · Cited by 4 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wilson, R. H., Nadeau, K. P., Jaworski, F. B., Tromberg, B. J., & Durkin, A. J. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.3.030901 · Cited by 415 · see citing works
Setchfield, K., Gorman, A., Simpson, A. H. R. W., Somekh, M. G., & Wright, A. J. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.1.010901 · Cited by 72 · see citing works
Hung, C.-H., Chou, T.-C., Hsu, C.-K., & Tseng, S.-H. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.000443 · Cited by 8 · see citing works
- Authors
- Nishimura, G., Kida, I., & Tamura, M.
- Affiliations
- Hokkaido University (JP)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-05-24
- Volume
- 51
- Issue
- 11
- Pages
- 2997-3011
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2020238249
- Cited by
- 20
- References
- 35
- Citations by year
- 2026: 1 · 2024: 3 · 2023: 1 · 2022: 1 · 2021: 2 · 2017: 1 · 2016: 3 · 2015: 3 · 2013: 1 · 2012: 1
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Hamamatsu Photonics K.K.
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- diffuse reflectance, reduced scattering coefficient, absorption coefficient, forearm, near-infrared spectroscopy, absorption spectra, tissue water content, water absorption bands, tissue heterogeneity
- MeSH terms
- Edema, Forearm, Humans, Magnetic Resonance Imaging, Radiography, Refractometry, Scattering, Radiation, Spectrum Analysis, Tissue Distribution, Water, Soft Tissue Injuries, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review