X-ray computed tomography
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized transverse axial scanning (tomography): Part 1. Description of system
Hounsfield, G. N. (1973) · The British Journal of Radiology · doi:10.1259/0007-1285-46-552-1016 · Cited by 3,924
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
The Fourier reconstruction of a head section
Shepp, L. A., & Logan, B. F. (1974) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1974.6499235 · Cited by 2,179
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Representation of a Function by Its Line Integrals, with Some Radiological Applications
Cormack, A. M. (1963) · Journal of Applied Physics · doi:10.1063/1.1729798 · Cited by 1,399
Kalender, W. A., Seissler, W., Klotz, E., & Vock, P. (1990) · Radiology · doi:10.1148/radiology.176.1.2353088 · Cited by 1,036
Self-citationComputed tomography : fundamentals, system technology, image quality, applications
Kalender, W. A. (2000) · Cited by 692
Self-citationImage Separation Radioisotope Scanning
Kuhl, D. E., & Edwards, R. Q. (1963) · Radiology · doi:10.1148/80.4.653 · Cited by 423
Quantitative Bone Mineral Analysis Using Dual Energy Computed Tomography
GENANT, H. K., & BOYD, D. (1977) · Investigative Radiology · doi:10.1097/00004424-197711000-00015 · Cited by 397
ECG‐correlated image reconstruction from subsecond multi‐slice spiral CT scans of the heart
Kachelrieß, M., Ulzheimer, S., & Kalender, W. A. (2000) · Medical Physics · doi:10.1118/1.1286552 · Cited by 225
Self-citationKachelriess, M., & Kalender, W. A. (1998) · Medical Physics · doi:10.1118/1.598453 · Cited by 212
Self-citationFahrig, R., Fox, A. J., Lownie, S. P., & Holdsworth, D. W. (1997) · PubMed · Cited by 209
Vertebral bone mineral analysis: an integrated approach with CT.
Kalender, W. A., Klotz, E., & Suess, C. (1987) · Radiology · doi:10.1148/radiology.164.2.3602380 · Cited by 204
Self-citationKalender, W. A., Polacin, A., & Süss, C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00001 · Cited by 182
Self-citationRadiology of the skull and brain, technical aspects of computed tomography
Tsai, F. Y. (1981) · Journal of Computed Tomography · doi:10.1016/0149-936x(81)90063-1 · Cited by 118
Brain perfusion CT in acute stroke: current status
König, M. A. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00359-5 · Cited by 86
Measurement of Trabecular Bone Mineral by Dual Energy Computed Tomography
Adams, J. E., Chen, S., ADAMS, P. H., & Isherwood, I. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198206000-00028 · Cited by 85
Pan, X., Xia, D., Zou, Y. S., et al. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/011 · Cited by 56
電算機による横断軸性スキャニング(断層像) 第1部 装置に関する記述
Hounsfield, G. N. (1973) · British Journal of Radiology · Cited by 48
Cited by
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
The production of anatomical teaching resources using three‐dimensional (3D) printing technology
McMenamin, P. G., Quayle, M. R., McHenry, C. R., & Adams, J. W. (2014) · Anatomical Sciences Education · doi:10.1002/ase.1475 · Cited by 698
Computed tomography for dimensional metrology
Kruth, J. P., Bartscher, M., Carmignato, S., Schmitt, R., De Chiffre, L., & Weckenmann, A. (2011) · CIRP Annals · doi:10.1016/j.cirp.2011.05.006 · Cited by 684
Lee, N., Choi, S. H., & Hyeon, T. (2013) · Advanced Materials · doi:10.1002/adma.201300081 · Cited by 657
Metadata
- Authors
- Kalender, W. A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-06-20
- Volume
- 51
- Issue
- 13
- Pages
- R29-R43
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2157666152
- Cited by
- 689
- References
- 19
- FWCI
- 13.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.