Cell model for efficient simulation of wave propagation in human ventricular tissue under normal and pathological conditions
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
In this paper, we formulate a model for human ventricular cells that is efficient enough for whole organ arrhythmia simulations yet detailed enough to capture the effects of cell level processes such as current blocks and channelopathies. The model is obtained from our detailed human ventricular cell model by using mathematical techniques to reduce the number of variables from 19 to nine. We carefully compare our full and reduced model at the single cell, cable and 2D tissue level and show that the reduced model has a very similar behaviour. Importantly, the new model correctly produces the effects of current blocks and channelopathies on AP and spiral wave behaviour, processes at the core of current day arrhythmia research. The new model is well over four times more efficient than the full model. We conclude that the new model can be used for efficient simulations of the effects of current changes on arrhythmias in the human heart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impulses and Physiological States in Theoretical Models of Nerve Membrane
FitzHugh, R. (1961) · Biophysical Journal · doi:10.1016/s0006-3495(61)86902-6 · Cited by 6,258 · cited 2×
“Second generation ionic models (Luo and Rudy 1994, Noble et al 1998 ,W inslowet al 1999 ,R iceet al 1999, Iyer et al 2004) contain a lot of electrophysiological detail, but are computationally very expensive, whereas phenomenological models such as FitzHugh–Nagumo like models ( FitzHugh 1960, 1961, Nagumo et al 1962,…”
BackgroundAn Active Pulse Transmission Line Simulating Nerve Axon
Nagumo, J., Arimoto, S., & Yoshizawa, S. (1962) · Proceedings of the IRE · doi:10.1109/jrproc.1962.288235 · Cited by 4,194
Luo, C. H., & Rudy, Y. (1994) · Circulation Research · doi:10.1161/01.res.74.6.1071 · Cited by 1,589 · cited 1×
“Second generation ionic models (Luo and Rudy 1994, Noble et al 1998, Winslow et al 1999, Rice et al 1999, Iyer et al 2004) contain a lot of electrophysiological detail, but are computationally very expensive, whereas phenomenological models such as FitzHugh–Nagumo like models (FitzHugh 1960, 1961,…”
BackgroundKeener, J., & Sneyd, J. (1998) · Interdisciplinary Applied Mathematics · doi:10.1007/b98841 · Cited by 1,529
Luo, C. H., & Rudy, Y. (1991) · Circulation Research · doi:10.1161/01.res.68.6.1501 · Cited by 1,468 · cited 1×
“This results in an Ltype calcium current description with only voltage dependent gates, similar to I CaL in Bernus et al (2002), Luo and Rudy (1991), Zhang et al (2000).”
ResultA model for human ventricular tissue
ten Tusscher, K. H. W. J., Noble, D., Noble, P. J., & Panfilov, A. V. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00794.2003 · Cited by 1,416
Self-citationCourtemanche, M., Ramirez, R. J., & Nattel, S. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.1.h301 · Cited by 1,218 · cited 1×
“This peak is absent in the reduced model due to the instantaneous rather than time dependent inactivation of I Kr (x r2∞ ), as is the case in most models (Zeng et al 1995, Priebe and Beuckelmann 1998, Courtemanche et al 1998, Iyer et al 2004).”
ResultAlternans and spiral breakup in a human ventricular tissue model
ten Tusscher, K. H. W. J., & Panfilov, A. V. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00109.2006 · Cited by 1,122
Self-citationFenton, F., & Karma, A. (1998) · Chaos: An Interdisciplinary Journal of Nonlinear Science · doi:10.1063/1.166311 · Cited by 862 · cited 6×
“Second generation ionic models (Luo and Rudy 1994, Noble et al 1998, Winslow et al 1999, Rice et al 1999, Iyer et al 2004) contain a lot of electrophysiological detail, but are computationally very expensive, whereas phenomenological models such as FitzHugh–Nagumo like models (FitzHugh 1960, 1961, Nagumo et al 1962, A…”
BackgroundInfluentialWinslow, R. L., Rice, J., Jafri, S., Marbán, E., & O’Rourke, B. (1999) · Circulation Research · doi:10.1161/01.res.84.5.571 · Cited by 797
Cited by
hERG K+Channels: Structure, Function, and Clinical Significance
Vandenberg, J. I., Perry, M. D., Perrin, M. J., Mann, S. A., Ke, Y., & Hill, A. P. (2012) · Physiological Reviews · doi:10.1152/physrev.00036.2011 · Cited by 696
A novel computational model of the human ventricular action potential and Ca transient
Grandi, E., Pasqualini, F. S., & Bers, D. M. (2010) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2009.09.019 · Cited by 450
Minimal model for human ventricular action potentials in tissue
Bueno-Orovio, A., Cherry, E. M., & Fenton, F. H. (2008) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2008.03.029 · Cited by 409
Passini, E., Britton, O. J., Lu, H. R., Rohrbacher, J., Hermans, A. N., Gallacher, D. J., Greig, R. J. H., Bueno-Orovio, A., & Rodriguez, B. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00668 · Cited by 326
Quarteroni, A., Lassila, T., Rossi, S., & Ruiz-Baier, R. (2017) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2016.05.031 · Cited by 248
“In general, the best compromise between computational efficiency and clinical relevance of models has been obtained by considering simplifications of realistic cell models by first eliminating some internal variables to reduce the stiffness of the system [48,49], then treating only the potential v and the gating varia…”
BackgroundMethodThe cardiovascular system: Mathematical modelling, numerical algorithms and clinical applications
Quarteroni, A., Manzoni, A., & Vergara, C. (2017) · Acta Numerica · doi:10.1017/s0962492917000046 · Cited by 232
A guide to modelling cardiac electrical activity in anatomically detailed ventricles
Clayton, R. H., & Panfilov, A. V. (2008) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.07.004 · Cited by 220
“Recently, a model which has a complexity similar to LR1 was also proposed for human ventricular cells (TenTusscher and Panfilov, 2006).”
BackgroundSelf-citationGillette, K., Gsell, M. A. F., Prassl, A. J., Karabelas, E., Reiter, U., Reiter, G., Grandits, T., Payer, C., Štern, D., Urschler, M., et al. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102080 · Cited by 194
Optimization of an In silico Cardiac Cell Model for Proarrhythmia Risk Assessment
Dutta, S., Chang, K. C., Beattie, K. A., Sheng, J., Tran, P. N., Wu, W. W., Wu, M., Strauss, D. G., Colatsky, T., & Li, Z. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00616 · Cited by 184
Three-dimensional cardiac computational modelling: methods, features and applications.
Lopez-Perez, A., Sebastian, R., & Ferrero, J. M. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0033-5 · Cited by 151
“The main reason is the fast upstroke of cellular depolarisation, which produces a step-like wavefront over a small spatial extent [68].”
BackgroundMethodRecent developments in using mechanistic cardiac modelling for drug safety evaluation
Davies, M. R., Wang, K., Mirams, G. R., Caruso, A., Noble, D., Walz, A., Lavé, T., Schuler, F., Singer, T., & Polonchuk, L. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.02.003 · Cited by 66
Validation and Trustworthiness of Multiscale Models of Cardiac Electrophysiology
Pathmanathan, P., & Gray, R. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00106 · Cited by 63
Metadata
- Authors
- Tusscher, K. H. W. J. T., & Panfilov, A. V.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-11-08
- Volume
- 51
- Issue
- 23
- Pages
- 6141-6156
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2123892496
- Cited by
- 206
- References
- 46
- FWCI
- 6.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.