The modified Beer–Lambert law revisited
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The modified Beer-Lambert law (MBLL) is the basis of continuous-wave near-infrared tissue spectroscopy (cwNIRS). The differential form of MBLL (dMBLL) states that the change in light attenuation is proportional to the changes in the concentrations of tissue chromophores, mainly oxy- and deoxyhaemoglobin. If attenuation changes are measured at two or more wavelengths, concentration changes can be calculated. The dMBLL is based on two assumptions: (1) the absorption of the tissue changes homogeneously, and (2) the scattering loss is constant. It is known that absorption changes are usually inhomogeneous, and therefore dMBLL underestimates the changes in concentrations (partial volume effect) and every calculated value is influenced by the change in the concentration of other chromophores (cross-talk between chromophores). However, the error introduced by the second assumption (cross-talk of scattering changes) has not been assessed previously. An analytically treatable special case (semi-infinite, homogeneous medium, with optical properties of the cerebral cortex) is utilized here to estimate its order of magnitude. We show that the per cent change of the transport scattering coefficient and that of the absorption coefficient have an approximately equal effect on the changes of attenuation, and a 1% increase in scattering increases the estimated concentration changes by about 0.5 microM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
Contini, D., Martelli, F., & Zaccanti, G. (1997) · Applied Optics · doi:10.1364/ao.36.004587 · Cited by 460
Hiraoka, M., Firbank, M., Essenpreis, M., Cope, M., Arridge, S. R., Zee, P. V. D., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/12/011 · Cited by 374
Comment on the modified Beer–Lambert law for scattering media
Sassaroli, A., & Fantini, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/n07 · Cited by 352 · cited 1×
“Recently, Sassaroli and Fantini (2004) showed that the above equation is incorrect (L must be substituted by its average over the range of absorption coefficient 0–µa), but the differential form of the MBLL (dMBLL) still holds for relatively small changes of attenuation, if G can be regarded…”
BackgroundTorricelli, A., Pifferi, A., Taroni, P., Giambattistelli, E., & Cubeddu, R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/313 · Cited by 173
Uludaǧ, K., Steinbrink, J. M., Villringer, A., & Obrig, H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.02.023 · Cited by 127
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
“Advantages and weakness of this simplified method have been extensively discussed in several papers [15,84,85].”
MethodLloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Enhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
A wearable multi-channel fNIRS system for brain imaging in freely moving subjects
Piper, S. K., Krueger, A., Koch, S. P., Mehnert, J., Habermehl, C., Steinbrink, J., Obrig, H., & Schmitz, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.062 · Cited by 463
Beer–Lambert law for optical tissue diagnostics: current state of the art and the main limitations
Oshina, I., & Spigulis, J. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.10.100901 · Cited by 273
Liao, Y.-Y., Tseng, H.-Y., Lin, Y.-J., Wang, C.-J., & Hsu, W.-C. (2020) · European Journal of Physical and Rehabilitation Medicine · doi:10.23736/s1973-9087.19.05899-4 · Cited by 265
Ahn, S., Nguyen, T., Jang, H., Kim, J. G., & Jun, S. C. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00219 · Cited by 254
Pollonini, L., Olds, C., Abaya, H., Bortfeld, H., Beauchamp, M. S., & Oghalai, J. S. (2014) · Hearing Research · doi:10.1016/j.heares.2013.11.007 · Cited by 251
“Finally, the modified BeereLambert law (Cope et al., 1988; Kocsis et al., 2006) was applied to calculate the changes in oxygenated and deoxygenated hemoglobin concentration for each channel and time point.”
MethodVisible light. Part I: Properties and cutaneous effects of visible light
Austin, E., Geisler, A. N., Nguyen, J., Kohli, I., Hamzavi, I., Lim, H. W., & Jagdeo, J. (2021) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2021.02.048 · Cited by 238
Wang, X., Tian, F., Soni, S. S., Gonzalez-Lima, F., & Liu, H. (2016) · Scientific Reports · doi:10.1038/srep30540 · Cited by 219
Simultaneous acquisition of EEG and NIRS during cognitive tasks for an open access dataset
Shin, J., von Lühmann, A., Kim, D.-W., Mehnert, J., Hwang, H.-J., & Müller, K.-R. (2018) · Scientific Data · doi:10.1038/sdata.2018.3 · Cited by 218
Abdelnour, A. F., & Huppert, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.01.033 · Cited by 208
“In functional NIRS studies, optical absorption changes ΔOD (optical density), are assumed to be small, and can be modeled as a linear combination of changes in oxy- and deoxy-hemoglobin as given by the modified Beer–Lambert law (MBLL) (Cope et al., 1988; Kocsis et al., 2006).”
MethodWireless miniaturized in-vivo near infrared imaging
Muehlemann, T., Haensse, D., & Wolf, M. (2008) · Optics Express · doi:10.1364/oe.16.010323 · Cited by 162
Multi-wavelength photoplethysmography method for skin arterial pulse extraction
Liu, J., Yan, B. P.-Y., Dai, W.-X., Ding, X.-R., Zhang, Y.-T., & Zhao, N. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.004313 · Cited by 107
Li, L., Zeng, L., Lin, Z.-J., Cazzell, M., & Liu, H. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.5.050801 · Cited by 78
Kable, J. A., Coles, C. D., & Mattson, S. N. (2020) · Developmental Neuropsychology · doi:10.1080/87565641.2020.1712604 · Cited by 14
Metadata
- Authors
- Kocsis, L., Herman, P., & Eke, A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-02-15
- Volume
- 51
- Issue
- 5
- Pages
- N91-N98
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2005593275
- Cited by
- 679
- References
- 12
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.