The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Spatio-temporal analysis of molecular delivery through the blood–brain barrier using focused ultrasound
Open accessAbstract
The deposition of gadolinium through ultrasound-induced blood-brain barrier (BBB) openings in the murine hippocampus was investigated. First, wave propagation simulations through the intact mouse skull revealed minimal beam distortion while thermal deposition simulations, at the same sonication parameters used to induce BBB opening in vivo, revealed temperature increases lower than 0.5 degrees C. The simulation results were validated experimentally in ex vivo skulls (m = 6) and in vitro tissue specimens. Then, in vivo mice (n = 9) were injected with microbubbles (Optison; 25-50 microl) and sonicated (frequency: 1.525 MHz, pressure amplitudes: 0.5-1.1 MPa, burst duration: 20 ms, duty cycle: 20%, durations: 2-4 shots, 30 s per shot, 30 s interval) at the left hippocampus, through intact skin and skull. Sequential, high-resolution, T1-weighted MRI (9.4 Tesla, in-plane resolution: 75 microm, scan time: 45-180 min) with gadolinium (Omniscan; 0.5 ml) injected intraperitoneally revealed a threshold of the BBB opening at 0.67 MPa and BBB closing within 28 h from opening. The contrast-enhancement area and gadolinium deposition path were monitored over time and the influence of vessel density, size and location was determined. Sonicated arteries, or their immediate surroundings, depicted greater contrast enhancement than sonicated homogeneous brain tissue regions. In conclusion, gadolinium was delivered through a transiently opened BBB and contained to a specific brain region (i.e., the hippocampus) using a single-element focused ultrasound transducer. It was also found that the amount of gadolinium deposited in the hippocampal region increased with the acoustic pressure and that the spatial distribution of the BBB opening was determined not only by the ultrasound beam, but also by the vasculature of the targeted brain region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A more localized transient disruption of BBB is accomplished by using magnetic resonance imaging-guided focused ultrasound in combination with IV infusion of microbubbles (FUS-MB) (Fig. 4b), which induce temporary BBB opening even in NHPs [134–137].”
From Designing and optimizing AAV-mediated gene therapy for neurodegenerative diseases: from bench to bedside (2024) · cites this paper as [135]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,655
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,988
The blood-brain barrier: Bottleneck in brain drug development
Pardridge, W. M. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.3 · Cited by 2,798
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N. J., Vykhodtseva, N. I., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,463
Neppiras, E. A. (1980) · Physics Reports · doi:10.1016/0370-1573(80)90115-5 · Cited by 777
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Sheikov, N. A., McDannold, N. J., Vykhodtseva, N. I., Jolesz, F. A., & Hynynen, K. (2004) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.04.010 · Cited by 619
Aubry, J., Tanter, M., Pernot, M., Thomas, J.-L., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1529663 · Cited by 584
Self-citation
Research works printed but not linked: 4
- Choi J J Small S A Konofagou E E, 2006, Ultrasonics Symp. IEEE
- Choi J J Wang S Morrison B Konofagou E E, 2007, Ultrasonics Symp. IEEE
- Hynynen K, 2003, Acta Neurochir. Suppl., 86, 555
- Pernot M Aubry J F Tanter M Andre F Fink M, 2004, Ultrasonics Symp. IEEE
Cited by
Sorted by citations
Bhaskar, S. M. M., Tian, F., Stoeger, T., Kreyling, W. G., de la Fuente, J. M., Grazú, V., Borm, P. J. A., Estrada, G. G., Ntziachristos, V., & Razansky, D. (2010) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-7-3 · Cited by 510
Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering
Qin, S., Caskey, C. F., & Ferrara, K. W. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/6/r01 · Cited by 453
Henderson, T. A., & Morries, L. D. (2015) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s78182 · Cited by 432
Focused ultrasound-mediated drug delivery through the blood–brain barrier
Burgess, A., Shah, K., Hough, O., & Hynynen, K. (2015) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.2015.1028369 · Cited by 332
Cavitation microstreaming and stress fields created by microbubbles
Collis, J., Manasseh, R., Liovic, P., Tho, P., Ooi, A. S. H., Petkovic‐Duran, K., & Zhu, Y. (2009) · Ultrasonics · doi:10.1016/j.ultras.2009.10.002 · Cited by 310
Ultrasound treatment of neurological diseases — current and emerging applications
Leinenga, G., Langton, C. M., Nisbet, R. M., & Götz, J. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.13 · Cited by 274
Microbubble-Size Dependence of Focused Ultrasound-Induced Blood–Brain Barrier Opening in MiceIn Vivo
Choi, J. J., Feshitan, J. A., Baseri, B., Wang, S., Tung, Y., Borden, M. A., & Konofagou, E. E. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2034533 · Cited by 258
Self-citationTung, Y., Vlachos, F., Choi, J. J., Deffieux, T., Selert, K., & Konofagou, E. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/20/007 · Cited by 246
Self-citationChoi, J. J., Wang, S., Tung, Y., Morrison, B., & Konofagou, E. E. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.08.006 · Cited by 205
Self-citationTung, Y., Vlachos, F., Feshitan, J. A., Borden, M. A., & Konofagou, E. E. (2011) · The Journal of the Acoustical Society of America · doi:10.1121/1.3646905 · Cited by 195
Self-citationUltrasound-Induced Blood-Brain Barrier Opening
Konofagou, E., Tung, Y.-S., Choi, J. J., Deffieux, T., Baseri, B., & Vlachos, F. (2012) · Current Pharmaceutical Biotechnology · doi:10.2174/138920112800624364 · Cited by 183
Self-citationOptimization of the Ultrasound-Induced Blood-Brain Barrier Opening
Konofagou, E. (2012) · Theranostics · doi:10.7150/thno.5576 · Cited by 163
Self-citationSonoporation, drug delivery, and gene therapy
Liang, H.-D., Tang, J., & Halliwell, M. (2009) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim565 · Cited by 168
Baseri, B., Choi, J. J., Tung, Y., & Konofagou, E. E. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.06.005 · Cited by 161
Self-citationChen, C., Sheeran, P. S., Wu, S.-Y., Olumolade, O., Dayton, P. A., & Konofagou, E. E. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.09.025 · Cited by 163
Self-citationNoninvasive and localized neuronal delivery using short ultrasonic pulses and microbubbles
Choi, J. J., Selert, K., Vlachos, F., Wong, A., & Konofagou, E. E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105116108 · Cited by 160
Self-citationChoi, J. J., Selert, K., Gao, Z., Samiotaki, G., Baseri, B., & Konofagou, E. E. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.155 · Cited by 153
Self-citationWang, S., Olumolade, O., Sun, T., Samiotaki, G., & Konofagou, E. E. (2014) · Gene Therapy · doi:10.1038/gt.2014.91 · Cited by 146
Self-citationUltrasound targeted microbubble destruction for drug and gene delivery
Mayer, C. R., Geis, N. A., Katus, H. A., & Bekeredjian, R. (2008) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.5.10.1121 · Cited by 135
Baseri, B., Choi, J. J., Deffieux, T., Samiotaki, G., Tung, Y., Olumolade, O., Small, S. A., Morrison, B., & Konofagou, E. E. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/7/n65 · Cited by 131
Self-citationDeffieux, T., & Konofagou, E. E. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1738 · Cited by 126
Self-citationTung, Y.-S., Marquet, F., Teichert, T., Ferrera, V., & Konofagou, E. E. (2011) · Applied Physics Letters · doi:10.1063/1.3580763 · Cited by 119
Self-citationChallenges for molecular neuroimaging with MRI
Lelyveld, V. S., Atanasijevic, T., & Jasanoff, A. (2010) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20221 · Cited by 106
Samiotaki, G., & Konofagou, E. E. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.6644731 · Cited by 104
Self-citationSonochemotherapy: from bench to bedside
Lammertink, B., Bos, C., Deckers, R., Storm, G., MOONEN, C. T. W., & Escoffre, J. (2015) · Frontiers in Pharmacology · doi:10.3389/fphar.2015.00138 · Cited by 105
Stimuli‐Responsive Materials for Biomedical Applications
do Nascimento, A. T., Stoddart, P. R., Goris, T., Kael, M., Manasseh, R., Alt, K., Tashkandi, J., Kim, B. C., & Moulton, S. E. (2025) · Advanced Materials · doi:10.1002/adma.202507559 · Cited by 100
An MRI‐compatible system for focused ultrasound experiments in small animal models
Chopra, R., Curiel, L., Staruch, R., Morrison, L., & Hynynen, K. (2009) · Medical Physics · doi:10.1118/1.3115680 · Cited by 94
Chopra, R., Vykhodtseva, N., & Hynynen, K. (2010) · ACS Chemical Neuroscience · doi:10.1021/cn9000445 · Cited by 93
Morse, S. V., Pouliopoulos, A. N., Chan, T. G., Copping, M. J., Lin, J., Long, N. J., & Choi, J. J. (2019) · Radiology · doi:10.1148/radiol.2019181625 · Cited by 91
Self-citationChoi, J. J., Wang, S., Brown, T. R., Small, S. A., Duff, K., & Konofagou, E. E. (2008) · Ultrasonic Imaging · doi:10.1177/016173460803000304 · Cited by 89
Self-citationTung, Y., Choi, J. J., Baseri, B., & Konofagou, E. E. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.009 · Cited by 89
Self-citationPower cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles
Burgess, M. T., Apostolakis, I., & Konofagou, E. E. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aab05c · Cited by 92
Self-citationTargeted Drug Delivery Across the blood–brain Barrier Using Ultrasound Technique
Deng, C. X. (2010) · Therapeutic Delivery · doi:10.4155/tde.10.66 · Cited by 85
Hijnen, N. M., Heijman, E., Köhler, M. O., Ylihautala, M., Ehnholm, G. J., Simonetti, A. W., & Grüll, H. (2012) · International Journal of Hyperthermia · doi:10.3109/02656736.2011.648137 · Cited by 78
Acoustic Holograms for Bilateral Blood-Brain Barrier Opening in a Mouse Model
Jimenez-Gambin, S., Jiménez, N., Pouliopoulos, A. N., Benlloch, J., Konofagou, E., & Camarena, F. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3115553 · Cited by 72
Self-citationGuo, Y., Lee, H., Kim, C., Park, C., Yamamichi, A., Chuntova, P., Gallus, M., Bernabéu, M. O., Okada, H., Jo, H., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-52329-y · Cited by 70
McDannold, N. J., Zhang, Y., & Vykhodtseva, N. I. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.04.019 · Cited by 66
A New Brain Drug Delivery Strategy: Focused Ultrasound-Enhanced Intranasal Drug Delivery
Chen, H., Chen, C., Acosta, C., Wu, S.-Y., Sun, T., & Konofagou, E. E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0108880 · Cited by 69
Self-citationBroadband acoustic properties of a murine skull
Estrada, H., Rebling, J., Turner, J., & Razansky, D. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/5/1932 · Cited by 62
Pelekanos, M., Leinenga, G., Odabaee, M., Odabaee, M., Saifzadeh, S., Steck, R., & Götz, J. (2018) · Theranostics · doi:10.7150/thno.22852 · Cited by 58
Cheng, M., Li, F., Han, T., Yu, A. C. H., & Qin, P. (2018) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2018.12.031 · Cited by 59
Perspectives on cavitation enhanced endothelial layer permeability
Peruzzi, G., Sinibaldi, G., Silvani, G., Ruocco, G., & Casciola, C. M. (2018) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2018.02.027 · Cited by 61
Blood–brain barrier opening with focused ultrasound in experimental models of Parkinson's disease
Karakatsani, M. E., Blesa, J., & Konofagou, E. E. (2019) · Movement Disorders · doi:10.1002/mds.27804 · Cited by 58
Self-citationZhang, H., Lin, X., Wan, H., Li, J.-M., & Li, J.-M. (2009) · Microsurgery · doi:10.1002/micr.20644 · Cited by 55
Howles, G. P., Bing, K. F., Qi, Y. P., Rosenzweig, S. J., Nightingale, K. R., & Johnson, G. A. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22411 · Cited by 55
Sierra, C., Acosta, C., Chen, C., Wu, S.-Y., Karakatsani, M. E., Bernal, M., & Konofagou, E. E. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16652630 · Cited by 55
Self-citationPRODUCTION OF UNIFORMLY SIZED SERUM ALBUMIN AND DEXTROSE MICROBUBBLES
Borrelli, M., O'Brien, W., Bernock, L. J., Williams, H., Hamilton, E., Wu, J., Oelze, M., & Culp, W. (2011) · Ultrasonics sonochemistry · doi:10.1016/j.ultsonch.2011.05.010 · Cited by 52
Pouliopoulos, A. N., Li, C., Tinguely, M., Garbin, V., Tang, M., & Choi, J. J. (2016) · The Journal of the Acoustical Society of America · doi:10.1121/1.4964271 · Cited by 52
Self-citationYang, F., Liu, S., Ho, F., & Chang, C.-H. (2009) · The Journal of the Acoustical Society of America · doi:10.1121/1.3242376 · Cited by 49
Production of monodispersed micron-sized bubbles at high rates in a microfluidic device
Chen, C., Zhu, Y., Leech, P. W., & Manasseh, R. (2009) · Applied Physics Letters · doi:10.1063/1.3242019 · Cited by 51
Xu, L., Yao, S., Ding, Y. E., Xie, M., Feng, D., Sha, P., Tan, L., Bei, F., & Yao, Y. (2024) · Journal of Translational Medicine · doi:10.1186/s12967-024-05661-2 · Cited by 48
King, D. A., Malloy, M. J., Roberts, A. C., Haak, A., Yoder, C. C., & O’Brien, W. D. (2010) · The Journal of the Acoustical Society of America · doi:10.1121/1.3373405 · Cited by 48
Olumolade, O., Wang, S., Samiotaki, G., & Konofagou, E. E. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.05.004 · Cited by 48
Self-citationYang, F., Wang, H.-E., Lin, G.-L., Teng, M.-C., Lin, H.-H., Wong, T., & Liu, R.-S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.083071 · Cited by 47
Contrast Agent Kinetics in the Rabbit Brain During Exposure to Therapeutic Ultrasound
Goertz, D. E., Wright, C., & Hynynen, K. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.03.005 · Cited by 46
Karakatsani, M. E., Samiotaki, G., Downs, M. E., Ferrera, V. P., & Konofagou, E. E. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2681695 · Cited by 46
Self-citationKim, H. C., Al‐Mahrouki, A., Gorjizadeh, A., Karshafian, R., & Czarnota, G. J. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2013.01.012 · Cited by 44
Frequencies of acoustically interacting bubbles
Manasseh, R., & Ooi, A. S. H. (2009) · Bubble Science Engineering & Technology · doi:10.1179/175889709x446552 · Cited by 44
Yang, F., Lin, G.-L., Horng, S., Chang, T.-K., Wu, S.-Y., Wong, T., & Wang, H.-E. (2011) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2011.1897 · Cited by 43
Ultrasound-Induced Blood-Brain Barrier Opening for Drug Delivery
Alonso, A. (2014) · Monographs in clinical neuroscience/Frontiers of neurology and neuroscience/Monographs in neural sciences · doi:10.1159/000366242 · Cited by 42
Nanoparticle delivery enhancement with acoustically activated microbubbles
Mullin, L. B., Phillips, L. C., & Dayton, P. A. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2538 · Cited by 42
Pouliopoulos, A. N., Bonaccorsi, S., & Choi, J. J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/6941 · Cited by 42
Self-citationClustering dynamics of microbubbles exposed to low-pressure 1-MHz ultrasound
Lazarus, C., Pouliopoulos, A. N., Tinguely, M., Garbin, V., & Choi, J. J. (2017) · The Journal of the Acoustical Society of America · doi:10.1121/1.5010170 · Cited by 42
Self-citationTakado, Y., Cheng, T., Bastiaansen, J., Yoshihara, H. A. I., Lanz, B., Mishkovsky, M., Lengacher, S., & Comment, A. (2018) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.8b00066 · Cited by 42
Blackmore, D. G., Turpin, F. R., Mohamed, A. Z., Zong, F., Pandit, R., Pelekanos, M., Nasrallah, F. A., Sah, P., Bartlett, P. F., & Götz, J. (2018) · Theranostics · doi:10.7150/thno.27941 · Cited by 43
King, D. A., & O’Brien, W. D. (2011) · The Journal of the Acoustical Society of America · doi:10.1121/1.3523339 · Cited by 34
Improving drug delivery technology for treating neurodegenerative diseases
Choonara, Y. E., Kumar, P., Modi, G., & Pillay, V. (2016) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2016.1162152 · Cited by 34
Lin, K., Liu, H.-L., Hsu, P.-H., Chung, Y., Huang, W.-C., Chen, J., Wey, S., Yen, T., & Hsiao, I. (2009) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2009.04.011 · Cited by 33
Liao, A., Hsin-Chiao, H., Lin, Y., Chen, H.-K., & Wang, C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0138500 · Cited by 32
Zhang, Z., Xia, C., Xue, Y., & Liu, Y. (2009) · Journal of Neuroscience Research · doi:10.1002/jnr.22061 · Cited by 29
Yang, F., Horng, S., Lin, Y., & Kao, Y. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22297 · Cited by 29
Bioavailability and cytosolic kinases modulate response to deoxynucleoside therapy in TK2 deficiency
Gomez, C. L., Hewan, H., Sierra, C., Akman, H. O., Sanchez‐Quintero, M. J., Juanola‐Falgarona, M., Tadesse, S., Tanji, K., Konofagou, E. E., & Hirano, M. (2019) · EBioMedicine · doi:10.1016/j.ebiom.2019.07.037 · Cited by 29
Self-citationEmerging strategies for delivering antiangiogenic therapies to primary and metastatic brain tumors
Askoxylakis, V., Arvanitis, C., Wong, C. S. F., Ferraro, G. B., & Jain, R. K. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.06.011 · Cited by 27
Neuroimaging and traumatic brain injury: State of the field and voids in translational knowledge.
Bruce, E. D., Konda, S., Dean, D., Wang, E. W., Huang, J. H., & Little, D. M. (2015) · Molecular and cellular neurosciences · doi:10.1016/j.mcn.2015.03.017 · Cited by 25
Oscillatory motion of a spherical bubble in a non-Newtonian fluid
Cunha, F. R., & Albernaz, D. L. (2012) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/j.jnnfm.2012.10.010 · Cited by 25
Wang, Y., Zhou, J., Zhang, Y., Wang, X., & Chen, J. (2010) · Experimental Biology and Medicine · doi:10.1258/ebm.2010.010046 · Cited by 23
Galán-Acosta, L., Sierra, C., Leppert, A., Pouliopoulos, A. N., Kwon, N., Noel, R. L., Tambaro, S., Presto, J., Nilsson, P., Konofagou, E. E., et al. (2020) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2020.103498 · Cited by 23
Self-citationValdez, M. A., Fernandez, E., Matsunaga, T. O., Erickson, R. P., & Trouard, T. P. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.08.024 · Cited by 25
Lynch, M., Heinen, S., Markham-Coultes, K., O’Reilly, M. A., Slyke, P. V., Dumont, D., Hynynen, K., & Aubert, I. (2020) · International Journal of Medical Sciences · doi:10.7150/ijms.36775 · Cited by 22
Howles, G. P., Qi, Y. P., & Johnson, G. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.01.050 · Cited by 20
Pulsed Focal Ultrasound as a Non-Invasive Method to Deliver Exosomes in the Brain/Stroke
Alptekin, A., Khan, M. B., Ara, R., Rashid, M. H., Kong, F., Parvin, M., Frank, J. A., Chopra, R., Dhandapani, K. M., & Arbab, A. S. (2021) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2021.3091 · Cited by 19
Churchman, A. H., Mico, V., de Pablo, J. G., Peyman, S. A., Freear, S., & Evans, S. D. (2018) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.87 · Cited by 18
Behavioral alterations following blood-brain barrier disruption stimulated by focused ultrasound
Yang, F., Huang, S.-F., & Cheng, I. H.-J. (2016) · Oncotarget · doi:10.18632/oncotarget.8444 · Cited by 17
Yang, F., Ko, C.-E., Huang, S., Chung, I., & Chen, G.-S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092910 · Cited by 16
Microbubble Applications in Biomedicine
Dastgheyb, S., & Eisenbrey, J. R. (2013) · Elsevier eBooks · doi:10.1016/b978-0-323-22805-3.00011-6 · Cited by 14
Weng, J., Wu, S., Lin, W.-L., & Tseng, W. I. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22643 · Cited by 14
Shen, Y., Zhang, A., Guo, J., Guo, D., Chen, S., & Yu, H. (2014) · Bio-Medical Materials and Engineering · doi:10.3233/bme-141101 · Cited by 14
Weng, J., Wu, S., Yang, F., Lin, W.-L., & Tseng, W. I. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22174 · Cited by 12
Telichko, A. V., Lee, T., Jakovljevic, M., & Dahl, J. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.3035696 · Cited by 12
Liao, A., Wang, C., Wang, B., Lin, Y., Chuang, H., Liu, H., & Shih, C. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10450 · Cited by 11
Biomedical Technologies for In Vitro Screening and Controlled Delivery of Neuroactive Compounds
Frampton, J. P., Shuler, M. L., Shain, W. G., & Hynd, M. R. (2008) · Central Nervous System Agents in Medicinal Chemistry · doi:10.2174/187152408785699613 · Cited by 11
Davies, H. J., Morse, S. V., Copping, M. J., Sujarittam, K., Bourgin, V. D., Tang, M., & Choi, J. J. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.3026165 · Cited by 11
Self-citationYang, F., Chen, C.-C., Kao, Y., Chen, C.-L., Ko, C.-E., Horng, S., & Chen, R.-C. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.11.027 · Cited by 10
Zhang, H., Sierra, C., Kwon, N., Karakatsani, M. E., Jackson-Lewis, V. R., Przedborski, S., & Konofagou, E. E. (2018) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2018.8579677 · Cited by 10
Self-citationTissue blood volumes and weights in adult beagle dogs.
Cuddihy, R. G., Hall, R. P., HOBBS, C. H., Boecker, B. B., & Muggenburg, B. A. (1972) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 10
Ultrasound mediated drug delivery: The effect of microbubbles on a gel boundary
Caskey, C. F., Qin, S., & Ferrara, K. W. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335240 · Cited by 8
Mannangatti, P., Bhoopathi, P., Kumar, A., Das, S. K., Emdad, L., & Fisher, P. B. (2024) · Advances in cancer research · doi:10.1016/bs.acr.2024.06.003 · Cited by 7
Enhancement of Fluorescent Probe Penetration into Tumors In Vivo Using Unseeded Inertial Cavitation
Prieur, F., Pillon, A., Mestas, J., Cartron, V., Cèbe, P., Chansard, N., Lafond, M., & Lafon, C. (2016) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.01.021 · Cited by 7
Near-infrared photonic energy penetration—principles and practice
Henderson, T. A., & Morries, L. D. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815305-5.00006-3 · Cited by 7
Payne, E., Ooi, A. S. H., & Manasseh, R. (2011) · Therapeutic Delivery · doi:10.4155/tde.10.112 · Cited by 7
Metadata
- Authors
- Choi, J. J., Pernot, M., Brown, T. R., Small, S. A., & Konofagou, E. E.
- Affiliations
- Columbia University (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-08-31
- Volume
- 52
- Issue
- 18
- Pages
- 5509-5530
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2105351878
- Cited by
- 141
- References
- 34
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 5 · 2023: 3 · 2022: 6 · 2021: 2 · 2020: 5 · 2019: 6 · 2018: 8 · 2017: 5 · 2016: 11 · 2015: 8 · 2014: 6 · 2013: 8 · 2012: 9
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute on Aging (P50AG008702)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Ultrasound and Hyperthermia Applications
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biotechnology › Microbial Inactivation Methods
- Keywords
- focused ultrasound, blood-brain barrier opening, gadolinium deposition, hippocampus, microbubbles, acoustic pressure threshold, wave propagation simulation, T1-weighted imaging, contrast enhancement, cerebral vasculature, ultrasound-mediated drug delivery
- MeSH terms
- Albumins, Animals, Blood-Brain Barrier, Computer Simulation, Female, Fluorocarbons, Gadolinium, Hippocampus, Male, Metabolic Clearance Rate, Mice, Inbred C57BL, Models, Biological, Sonication, Tissue Distribution, Drug Delivery Systems, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review