The DOI matches its Crossref record.
A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9
Open accessAbstract
Fetuses are extremely radiosensitive and the protection of pregnant females against ionizing radiation is of particular interest in many health and medical physics applications. Existing models of pregnant females relied on simplified anatomical shapes or partial-body images of low resolutions. This paper reviews two general types of solid geometry modeling: constructive solid geometry (CSG) and boundary representation (BREP). It presents in detail a project to adopt the BREP modeling approach to systematically design whole-body radiation dosimetry models: a pregnant female and her fetus at the ends of three gestational periods of 3, 6 and 9 months. Based on previously published CT images of a 7-month pregnant female, the VIP-Man model and mesh organ models, this new set of pregnant female models was constructed using 3D surface modeling technologies instead of voxels. The organ masses were adjusted to agree with the reference data provided by the International Commission on Radiological Protection (ICRP) and previously published papers within 0.5%. The models were then voxelized for the purpose of performing dose calculations in identically implemented EGS4 and MCNPX Monte Carlo codes. The agreements of the fetal doses obtained from these two codes for this set of models were found to be within 2% for the majority of the external photon irradiation geometries of AP, PA, LAT, ROT and ISO at various energies. It is concluded that the so-called RPI-P3, RPI-P6 and RPI-P9 models have been reliably defined for Monte Carlo calculations. The paper also discusses the needs for future research and the possibility for the BREP method to become a major tool in the anatomical modeling for radiation dosimetry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Deep learning for tomographic image reconstruction
Wang, G., Ye, J. C., & De Man, B. (2020) · Nature Machine Intelligence · doi:10.1038/s42256-020-00273-z · Cited by 531
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2624938 · Cited by 455
The UF family of reference hybrid phantoms for computational radiation dosimetry
Lee, C., Lodwick, D., Hurtado, J., Pafundi, D., Williams, J. L., & Bolch, W. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/002 · Cited by 345
Metadata
- Authors
- Xu, X. G., Taranenko, V., Zhang, J., & Shi, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-11-15
- Volume
- 52
- Issue
- 23
- Pages
- 7023-7044
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2058386007
- Cited by
- 197
- References
- 0
- FWCI
- 11.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9. https://app.cochat.ai/papers/10.1088/0031-9155/52/23/017
- The paper
- Xu, X. G., Taranenko, V., Zhang, J., & Shi, C. (2007). A boundary-representation method for designing whole-body radiation dosimetry models: pregnant females at the ends of three gestational periods—RPI-P3, -P6 and -P9. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/52/23/017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.