Recent developments in PET detector technology
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Positron emission tomography (PET) is a tool for metabolic imaging that has been utilized since the earliest days of nuclear medicine. A key component of such imaging systems is the detector modules--an area of research and development with a long, rich history. Development of detectors for PET has often seen the migration of technologies, originally developed for high energy physics experiments, into prototype PET detectors. Of the many areas explored, some detector designs go on to be incorporated into prototype scanner systems and a few of these may go on to be seen in commercial scanners. There has been a steady, often very diverse development of prototype detectors, and the pace has accelerated with the increased use of PET in clinical studies (currently driven by PET/CT scanners) and the rapid proliferation of pre-clinical PET scanners for academic and commercial research applications. Most of these efforts are focused on scintillator-based detectors, although various alternatives continue to be considered. For example, wire chambers have been investigated many times over the years and more recently various solid-state devices have appeared in PET detector designs for very high spatial resolution applications. But even with scintillators, there have been a wide variety of designs and solutions investigated as developers search for solutions that offer very high spatial resolution, fast timing, high sensitivity and are yet cost effective. In this review, we will explore some of the recent developments in the quest for better PET detector technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barrett, H. H., Myers, K. J., & Rathee, S. (2004) · Medical Physics · doi:10.1118/1.1677252 · Cited by 1,065
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.
Pichler, B. J., Judenhofer, M. S., Catana, C., Walton, J. H., Kneilling, M., Nutt, R. E., Siegel, S. B., Claussen, C. D., & Cherry, S. R. (2006) · PubMed · Cited by 454
List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET
Parra, L., & Barrett, H. H. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700734 · Cited by 357
Emission Tomography: The Fundamentals of PET and SPECT
Wernick, M. N., & Aarsvold, J. N. (2004) · Cited by 353
Catana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
EMISSION TOMOGRAPHY: THE FUNDAMENTALS OF PET AND SPECT
Madsen, M. T. (2005) · Shock · doi:10.1097/00024382-200504000-00016 · Cited by 323
Tai, Y.-C., Chatziioannou, A. F., Yang, Y., Silverman, R. W., Meadors, K., Siegel, S., Newport, D. F., Stickel, J. R., & Cherry, S. R. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/303 · Cited by 273
Continuous-slice PENN-PET: a positron tomograph with volume imaging capability.
Karp, J. S., Muehllehner, G., Mankoff, D. A., Ordoñez, C. E., Ollinger, J. M., Daube-Witherspoon, M. E., Haigh, A. T., & Beerbohm, D. J. (1990) · PubMed · Cited by 236
Recent advances and future advances in time-of-flight PET
Moses, W. W. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.06.038 · Cited by 205
Depth of interaction decoding of a continuous crystal detector module
Ling, T., Lewellen, T. K., & Miyaoka, R. S. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/8/012 · Cited by 185
Self-citationModeling and incorporation of system response functions in 3-D whole body PET
Alessio, A. M., Kinahan, P. E., & Lewellen, T. K. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.873222 · Cited by 176
Self-citationPET/MR Images Acquired with a Compact MR-compatible PET Detector in a 7-T Magnet
Judenhofer, M. S., Catana, C., Swann, B. K., Siegel, S. B., Jung, W.-I., Nutt, R. E., Cherry, S. R., Claussen, C. D., & Pichler, B. J. (2007) · Radiology · doi:10.1148/radiol.2443061756 · Cited by 173
Investigation of time-of-flight benefit for fully 3-DPET
Surti, S., Karp, S., Popescu, L. M., Daube-Witherspoon, E., & Werner, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.871419 · Cited by 166
cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme
Joung, J., Miyaoka, R. S., & Lewellen, T. K. (2002) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(02)00861-6 · Cited by 163
Self-citationLewellen, T. K. (1998) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(98)80031-7 · Cited by 160
Self-citationDevelopment of a Combined microPET®-MR System
Lucas, A. J., Hawkes, R. C., Ansorge, R. E., Williams, G. B., Nutt, R., Clark, J. C., Fryer, T. D., & Carpenter, T. A. (2006) · Technology in Cancer Research & Treatment · doi:10.1177/153303460600500405 · Cited by 157
A detector head design for small-animal PET with silicon photomultipliers (SiPM)
Moehrs, S., Guerra, A. D., Herbert, D., & Mandelkern, M. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/004 · Cited by 154
Renker, D. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.016 · Cited by 117
Performance evaluation of the 32-module quadHIDAC small-animal PET scanner.
Schäfers, K. P., Reader, A. J., Kriens, M., Knoess, C., Schober, O., & Schäfers, M. A. (2005) · PubMed · Cited by 116
Detector development for microPET II: a 1 μl resolution PET scanner for small animal imaging
Chatziioannou, A., Tai, Y. C., Doshi, N., & Cherry, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/11/310 · Cited by 107
Raylman, R. R., Majewski, S., Velan, S. S., Lemieux, S. K., Kross, B., Popov, V., Smith, M. F., & Weisenberger, A. G. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.03.012 · Cited by 71
Evaluation of silicon photomultipliers: A promising new detector for MR compatible PET
McElroy, D. P., Saveliev, V. I., Reznik, A., & Rowlands, J. A. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.040 · Cited by 63
First achievement of less than 1 mm FWHM resolution in practical semiconductor animal PET scanner
Ishii, K., Kikuchi, Y., Matsuyama, S., Kanai, Y., Kotani, K., Itô, T., Yamazaki, H., Funaki, Y., Iwata, R., Itoh, M., et al. (2007) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2007.03.018 · Cited by 58
The Silicon Photomultiplier for application to high-resolution Positron Emission Tomography
Herbert, D., Moehrs, S., D’Ascenzo, N., Belcari, N., Guerra, A. D., Morsani, F., & Saveliev, V. I. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.11.020 · Cited by 53
Pragmatic fully 3D image reconstruction for the MiCES mouse imaging PET scanner
Lee, K., Kinahan, P. E., Fessler, J. A., Miyaoka, R. S., Janes, M. L., & Lewellen, T. K. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/19/008 · Cited by 44
Self-citationModeling and Incorporation of System Response Functions in 3D Whole Body PET
Alessio, A. M., Kinahan, P. E., & Lewellen, T. K. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466752 · Cited by 40
Self-citationDesign of a very high-resolution small animal PET scanner using a silicon scatter detector insert
Park, S.-J., Rogers, W. L., & Clinthorne, N. H. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/019 · Cited by 38
Park, S.-J., Rogers, W. L., Huh, S. S., Kagan, H., Honscheid, K., Burdette, D. J., Chesi, E., Lacasta, C., Llosa, G., Mikuž, M., et al. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/012 · Cited by 38
Characterisation of Geiger-mode avalanche photodiodes for medical imaging applications
Britvitch, I., Johnson, I., Renker, D., Stoykov, A., & Eckart Lorenz, G. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.089 · Cited by 37
Time-of-flight positron emission tomography using liquid xenon scintillation
Doke, T., Kikuchi, J., & Nishikido, F. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.07.067 · Cited by 36
Staelens, S. G., D’Asseler, Y., Vandenberghe, S., Koole, M. J. B., Lemahieu, I. A., & Rik Van De Walle, B. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/015 · Cited by 33
Study of multi-pixel Geiger-mode avalanche photodiodes as a read-out for PET
Musienko, Y., Auffray, E., Lecoq, P. R., Reucroft, S., Swain, J. D., & Trummer, J. (2006) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2006.10.109 · Cited by 19
Cited by
Ce3+-Doped garnet phosphors: composition modification, luminescence properties and applications
Xia, Z., & Meijerink, A. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00551a · Cited by 1,149
A concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
State of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 390
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
A novel, SiPM-array-based, monolithic scintillator detector for PET
Schaart, D. R., van Dam, H. T., Seifert, S., Vinke, R., Dendooven, P., Löhner, H., & Beekman, F. J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/11/015 · Cited by 286
Metadata
- Authors
- Lewellen, T. K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-11
- Volume
- 53
- Issue
- 17
- Pages
- R287-R317
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2160366775
- Cited by
- 336
- References
- 34
- FWCI
- 23.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.