Recent developments in PET detector technology
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Positron emission tomography (PET) is a tool for metabolic imaging that has been utilized since the earliest days of nuclear medicine. A key component of such imaging systems is the detector modules--an area of research and development with a long, rich history. Development of detectors for PET has often seen the migration of technologies, originally developed for high energy physics experiments, into prototype PET detectors. Of the many areas explored, some detector designs go on to be incorporated into prototype scanner systems and a few of these may go on to be seen in commercial scanners. There has been a steady, often very diverse development of prototype detectors, and the pace has accelerated with the increased use of PET in clinical studies (currently driven by PET/CT scanners) and the rapid proliferation of pre-clinical PET scanners for academic and commercial research applications. Most of these efforts are focused on scintillator-based detectors, although various alternatives continue to be considered. For example, wire chambers have been investigated many times over the years and more recently various solid-state devices have appeared in PET detector designs for very high spatial resolution applications. But even with scintillators, there have been a wide variety of designs and solutions investigated as developers search for solutions that offer very high spatial resolution, fast timing, high sensitivity and are yet cost effective. In this review, we will explore some of the recent developments in the quest for better PET detector technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Barrett, H. H., Myers, K. J., & Rathee, S. (2004) · Medical Physics · doi:10.1118/1.1677252 · Cited by 1,065
Surti, S., Kuhn, A., Werner, M. E., Perkins, A. E., Kolthammer, J. A., & Karp, J. S. (2007) · PubMed · Cited by 639
Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.
Pichler, B. J., Judenhofer, M. S., Catana, C., Walton, J. H., Kneilling, M., Nutt, R. E., Siegel, S. B., Claussen, C. D., & Cherry, S. R. (2006) · PubMed · Cited by 454
List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET
Parra, L., & Barrett, H. H. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700734 · Cited by 357
Emission Tomography: The Fundamentals of PET and SPECT
Wernick, M. N., & Aarsvold, J. N. (2004) · Cited by 353
Catana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
EMISSION TOMOGRAPHY: THE FUNDAMENTALS OF PET AND SPECT
Madsen, M. T. (2005) · Shock · doi:10.1097/00024382-200504000-00016 · Cited by 323
Tai, Y.-C., Chatziioannou, A. F., Yang, Y., Silverman, R. W., Meadors, K., Siegel, S., Newport, D. F., Stickel, J. R., & Cherry, S. R. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/303 · Cited by 273
Continuous-slice PENN-PET: a positron tomograph with volume imaging capability.
Karp, J. S., Muehllehner, G., Mankoff, D. A., Ordoñez, C. E., Ollinger, J. M., Daube-Witherspoon, M. E., Haigh, A. T., & Beerbohm, D. J. (1990) · PubMed · Cited by 236
Cited by
Ce3+-Doped garnet phosphors: composition modification, luminescence properties and applications
Xia, Z., & Meijerink, A. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00551a · Cited by 1,149
A concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
State of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 390
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
A novel, SiPM-array-based, monolithic scintillator detector for PET
Schaart, D. R., van Dam, H. T., Seifert, S., Vinke, R., Dendooven, P., Löhner, H., & Beekman, F. J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/11/015 · Cited by 286
PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging
Vandenberghe, S., & Marsden, P. K. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/4/r115 · Cited by 258
LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving time
Schaart, D. R., Seifert, S., Vinke, R., van Dam, H. T., Dendooven, P., Löhner, H., & Beekman, F. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/7/n02 · Cited by 225
Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Sarrut, D., Bała, M., Bardiès, M., Bert, J., Chauvin, M., Chatzipapas, K., Dupont, M., Etxebeste, A., M Fanchon, L., Jan, S., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abf276 · Cited by 204
“The increasing use of SiPMs (see section 2) in the context of PET imaging (Lewellen 2008, Cabello andZiegler 2018, Conti and Bendriem 2019)motivated the implementation of specific digitizermodules for analog and digital SiPMs (dSiPMs), so that both the complete scanner system and the single…”
BackgroundBraga, L. H. C., Gasparini, L., Grant, L., Henderson, R. K., Massari, N., Perenzoni, M., Stoppa, D., & Walker, R. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284351 · Cited by 195
Billé, A., Pelosi, E., Skanjeti, A., Arena, V., Errico, L., Borasio, P., Mancini, M., & Ardissone, F. (2009) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2009.04.003 · Cited by 186
“While new detector modules with higher spatial and temporal resolution and sensitivity are developed along with improvements in image reconstruction capabilities [25], further investigation is warranted to determine more precisely the actual benefit of integrated PET/CT implementation in the staging algorithm in patie…”
BackgroundRecent Advances and Future Progress in PET Instrumentation
Slomka, P. J., Pan, T., & Germano, G. (2016) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2015.09.006 · Cited by 177
Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard
Rausch, I., Ruiz, A., Valverde-Pascual, I., Cal-González, J., Beyer, T., & Carrio, I. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.215541 · Cited by 168
“In addition, alternatives to standard photomultiplier tubes (PMTs) are now available, such as avalanche photodiodes or silicon photomultipliers (SiPM) (6,7).”
BackgroundImage-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142
“In particular, from the hardware point of view more sophisticated signal processing techniques have resulted in better general performances of the systems (Pichler et al 2008, Van Eijk 2008, Lewellen 2008).”
MethodPerformance evaluation of the next generation solid-state digital photon counting PET/CT system
Zhang, J., Maniawski, P., & Knopp, M. V. (2018) · EJNMMI Research · doi:10.1186/s13550-018-0448-7 · Cited by 123
Metadata
- Authors
- Lewellen, T. K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-08-11
- Volume
- 53
- Issue
- 17
- Pages
- R287-R317
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2160366775
- Cited by
- 336
- References
- 34
- FWCI
- 23.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.