Tissue characterization using terahertz pulsed imaging in reflection geometry
Open accessThe DOI matches its Crossref record.
Abstract
Terahertz pulsed imaging (TPI) is a non-ionizing and non-destructive imaging technique that has been recently used to study a wide range of biological materials. The severe attenuation of terahertz radiation in samples with high water content means that biological samples need to be very thin if they are to be measured in transmission geometry. To overcome this limitation, samples could be measured in reflection geometry and this is the most feasible way in which TPI could be performed in a clinical setting. In this study, we therefore used TPI in reflection geometry to characterize the terahertz properties of several organ samples freshly harvested from laboratory rats. We observed differences in the measured time domain responses and determined the frequency-dependent optical properties to characterize the samples further. We found statistically significant differences between the tissue types. These results show that TPI has the potential to accurately differentiate between tissue types non-invasively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Baxter, J. B., & Guglietta, G. W. (2011) · Analytical Chemistry · doi:10.1021/ac200907z · Cited by 477
The potential of terahertz imaging for cancer diagnosis: A review of investigations to date.
Yu, C., Fan, S., Sun, Y., & Pickwell‐MacPherson, E. (2012) · PubMed · doi:10.3978/j.issn.2223-4292.2012.01.04 · Cited by 289
Self-citationTerahertz Imaging and Sensing for Healthcare: Current Status and Future Perspectives
Gezimati, M., & Singh, G. (2023) · IEEE Access · doi:10.1109/access.2023.3247196 · Cited by 162
Wilmink, G. J., Ibey, B. L., Rivest, B. D., Grundt, J. E., Roach, W. P., Tongue, T. D., Schulkin, B. J., Laman, N., Peralta, X. G., Roth, C. C., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3570648 · Cited by 109
Improved sample characterization in terahertz reflection imaging and spectroscopy
Huang, S., Ashworth, P. C., Kan, K. W., Chen, Y., Wallace, V. P., Zhang, Y.-T., & Pickwell-MacPherson, E. (2009) · Optics Express · doi:10.1364/oe.17.003848 · Cited by 96
Self-citation
Metadata
- Authors
- Huang, S. Y., Wang, Y. X. J., Yeung, D. K. W., Ahuja, A. T., Zhang, Y.-T., & Pickwell-MacPherson, E.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-12-10
- Volume
- 54
- Issue
- 1
- Pages
- 149-160
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2045219490
- Cited by
- 113
- References
- 0
- FWCI
- 8.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tissue characterization using terahertz pulsed imaging in reflection geometry. https://app.cochat.ai/papers/10.1088/0031-9155/54/1/010
- The paper
- Huang, S. Y., Wang, Y. X. J., Yeung, D. K. W., Ahuja, A. T., Zhang, Y.-T., & Pickwell-MacPherson, E. (2009). Tissue characterization using terahertz pulsed imaging in reflection geometry. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/54/1/010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.