Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering
Open accessThe DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
Microbubble contrast agents and the associated imaging systems have developed over the past 25 years, originating with manually-agitated fluids introduced for intra-coronary injection. Over this period, stabilizing shells and low diffusivity gas materials have been incorporated in microbubbles, extending stability in vitro and in vivo. Simultaneously, the interaction of these small gas bubbles with ultrasonic waves has been extensively studied, resulting in models for oscillation and increasingly sophisticated imaging strategies. Early studies recognized that echoes from microbubbles contained frequencies that are multiples of the microbubble resonance frequency. Although individual microbubble contrast agents cannot be resolved-given that their diameter is on the order of microns-nonlinear echoes from these agents are used to map regions of perfused tissue and to estimate the local microvascular flow rate. Such strategies overcome a fundamental limitation of previous ultrasound blood flow strategies; the previous Doppler-based strategies are insensitive to capillary flow. Further, the insonation of resonant bubbles results in interesting physical phenomena that have been widely studied for use in drug and gene delivery. Ultrasound pressure can enhance gas diffusion, rapidly fragment the agent into a set of smaller bubbles or displace the microbubble to a blood vessel wall. Insonation of a microbubble can also produce liquid jets and local shear stress that alter biological membranes and facilitate transport. In this review, we focus on the physical aspects of these agents, exploring microbubble imaging modes, models for microbubble oscillation and the interaction of the microbubble with the endothelium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Gray's anatomy: the anatomical basis of clinical practice
(2005) · Choice Reviews Online · doi:10.5860/choice.43-1300 · Cited by 4,152
VIII. On the pressure developed in a liquid during the collapse of a spherical cavity
Rayleigh, L. (1917) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440808635681 · Cited by 3,263
Cavitation And Bubble Dynamics
Brennen, C. E. (1995) · doi:10.1093/oso/9780195094091.001.0001 · Cited by 2,444
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Bubble Dynamics and Cavitation
Plesset, M. S., & Prosperetti, A. (1977) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.09.010177.001045 · Cited by 2,049
Wei, K., Jayaweera, A. R., Firoozan, S., Linka, A., Skyba, D. M., & Kaul, S. (1998) · Circulation · doi:10.1161/01.cir.97.5.473 · Cited by 1,616
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
The Dynamics of Cavitation Bubbles
Plesset, M. S. (1949) · Journal of Applied Mechanics · doi:10.1115/1.4009975 · Cited by 1,406
XVI.On musical air-bubbles and the sounds of running water
Minnaert, M. (1933) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786443309462277 · Cited by 1,350
Cited by
Sonochemical synthesis of nanomaterials
Xu, H., Zeiger, B. W., & Suslick, K. S. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35282f · Cited by 1,161
Physics of bubble oscillations
Lauterborn, W., & Kurz, T. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/10/106501 · Cited by 816
Microbubble compositions, properties and biomedical applications
Sirsi, S. R., & Borden, M. A. (2009) · Bubble Science, Engineering & Technology · doi:10.1179/175889709x446507 · Cited by 594
State-of-the-art materials for ultrasound-triggered drug delivery
Sirsi, S. R., & Borden, M. A. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.010 · Cited by 488
Rapoport, N., Nam, K.-H., Gupta, R., Gao, Z., Mohan, P., Payne, A., Todd, N., Liu, X., Kim, T., Shea, J., et al. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.01.022 · Cited by 423
Cancer‐Associated, Stimuli‐Driven, Turn on Theranostics for Multimodality Imaging and Therapy
Li, X., Kim, J., Yoon, J., & Chen, X. (2017) · Advanced Materials · doi:10.1002/adma.201606857 · Cited by 362
Lipid-Shelled Vehicles: Engineering for Ultrasound Molecular Imaging and Drug Delivery
Ferrara, K. W., Borden, M. A., & Zhang, H. (2009) · Accounts of Chemical Research · doi:10.1021/ar8002442 · Cited by 332
Self-citationBlood Vessel Deformations on Microsecond Time Scales by Ultrasonic Cavitation
Chen, H., Kreider, W., Brayman, A. A., Bailey, M. R., & Matula, T. J. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.034301 · Cited by 314
Min, K. H., Min, H. S., Lee, H. J., Park, D. J., Yhee, J. Y., Kim, K., Kwon, I. C., Jeong, S. Y., Silvestre, O. F., Chen, X., et al. (2015) · ACS Nano · doi:10.1021/nn506210a · Cited by 265
Phase‐shift, stimuli‐responsive perfluorocarbon nanodroplets for drug delivery to cancer
Rapoport, N. (2012) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1176 · Cited by 246
Getting Drugs Across Biological Barriers
Yang, R., Wei, T., Goldberg, H., Wang, W., Cullion, K., & Kohane, D. S. (2017) · Advanced Materials · doi:10.1002/adma.201606596 · Cited by 234
Biomedical nanomaterials for imaging-guided cancer therapy
Huang, Y., He, S., Cao, W., Cai, K., & Liang, X.-J. (2012) · Nanoscale · doi:10.1039/c2nr31715j · Cited by 233
Advances in Ultrasound Mediated Gene Therapy Using Microbubble Contrast Agents
Sirsi, S. R., & Borden, M. A. (2012) · Theranostics · doi:10.7150/thno.4306 · Cited by 226
“Inertial cavitation of MCA’s near a cell boundary can cause transient membrane ruptures due to shock waves and jetting during microbubble collapse [11].”
BackgroundInfluentialTargeted Nanotheranostics for Future Personalized Medicine: Recent Progress in Cancer Therapy
Jo, S. D., Ku, S. H., Won, Y.-Y., Kim, S. H., & Kwon, I. C. (2016) · Theranostics · doi:10.7150/thno.15335 · Cited by 218
Opening doors with ultrasound and microbubbles: Beating biological barriers to promote drug delivery
Deprez, J., Lajoinie, G., Engelen, Y., De Smedt, S. C., & Lentacker, I. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.02.015 · Cited by 207
Ultrasound-Based Micro-/Nanosystems for Biomedical Applications
Huang, H., Zheng, Y., Chang, M., Song, J., Xia, L., Wu, C., Jia, W., Ren, H., Feng, W., & Chen, Y. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00009 · Cited by 183
Siafaka, P. I., Okur, N. Ü., Karantas, I. D., Okur, M. E., & Gündoğdu, E. A. (2021) · Asian Journal of Pharmaceutical Sciences · doi:10.1016/j.ajps.2020.03.003 · Cited by 170
Cardiovascular Molecular Imaging: Focus on Clinical Translation
Chen, I. Y., & Wu, J. C. (2011) · Circulation · doi:10.1161/circulationaha.109.916338 · Cited by 165
Microcapsule mechanics: From stability to function
Neubauer, M. P., Poehlmann, M., & Fery, A. (2014) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2013.11.016 · Cited by 165
Sonoporation of endothelial cells by vibrating targeted microbubbles
Kooiman, K., Foppen-Harteveld, M., der Steen, A. F. W. V., & de Jong, N. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.04.008 · Cited by 162
20 years of ultrasound contrast agent modeling
Faez, T., Emmer, M., Kooiman, K., Versluis, M., van der Steen, A. F. W., & de Jong, N. (2013) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2533 · Cited by 160
Microbubble Dissolution in a Multigas Environment
Kwan, J. J., & Borden, M. A. (2010) · Langmuir · doi:10.1021/la904088p · Cited by 159
Metadata
- Authors
- Qin, S., Caskey, C. F., & Ferrara, K. W.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-02-19
- Volume
- 54
- Issue
- 6
- Pages
- R27-R57
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2050370670
- Cited by
- 453
- References
- 99
- FWCI
- 19.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.