Non-invasive transcranial ultrasound therapy based on a 3D CT scan: protocol validation and in vitro results
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
A non-invasive protocol for transcranial brain tissue ablation with ultrasound is studied and validated in vitro. The skull induces strong aberrations both in phase and in amplitude, resulting in a severe degradation of the beam shape. Adaptive corrections of the distortions induced by the skull bone are performed using a previous 3D computational tomography scan acquisition (CT) of the skull bone structure. These CT scan data are used as entry parameters in a FDTD (finite differences time domain) simulation of the full wave propagation equation. A numerical computation is used to deduce the impulse response relating the targeted location and the ultrasound therapeutic array, thus providing a virtual time-reversal mirror. This impulse response is then time-reversed and transmitted experimentally by a therapeutic array positioned exactly in the same referential frame as the one used during CT scan acquisitions. In vitro experiments are conducted on monkey and human skull specimens using an array of 300 transmit elements working at a central frequency of 1 MHz. These experiments show a precise refocusing of the ultrasonic beam at the targeted location with a positioning error lower than 0.7 mm. The complete validation of this transcranial adaptive focusing procedure paves the way to in vivo animal and human transcranial HIFU investigations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goodman, J. W. (1985) · Cited by 4,004
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Aubry, J.-F., Tanter, M., Pernot, M., Thomas, J.-L., & Fink, M. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1529663 · Cited by 581
Self-citationLeksell, L. (1983) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.46.9.797 · Cited by 521
A non-invasive method for focusing ultrasound through the human skull
Clement, G. T., & Hynynen, K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/8/301 · Cited by 510
Arrhenius relationships from the molecule and cell to the clinic
Dewey, W. C. (1994) · International Journal of Hyperthermia · doi:10.3109/02656739409009351 · Cited by 501
Production of Focal Destructive Lesions in the Central Nervous System With Ultrasound
Fry, W. J., Mosberg, W. H., Barnard, J. W., & Fry, F. J. (1954) · Journal of Neurosurgery · doi:10.3171/jns.1954.11.5.0471 · Cited by 457
Understanding and Using DICOM, the Data Interchange Standard for Biomedical Imaging
Bidgood, W. D., Horii, S. C., Prior, F. W., & Van Syckle, D. E. (1997) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1997.0040199 · Cited by 449
Choi, J. J., Pernot, M., Small, S. A., & Konofagou, E. E. (2007) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2006.07.018 · Cited by 355
Self-citation
Cited by
High intensity focused ultrasound in clinical tumor ablation
Zhou, Y.-F. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i1.8 · Cited by 625
Neuromodulation with single‐element transcranial focused ultrasound in human thalamus
Legon, W., Ai, L., Bansal, P., & Mueller, J. K. (2018) · Human Brain Mapping · doi:10.1002/hbm.23981 · Cited by 334
Intrinsic functional neuron-type selectivity of transcranial focused ultrasound neuromodulation
Yu, K., Niu, X., Krook-Magnuson, E., & He, B. (2021) · Nature Communications · doi:10.1038/s41467-021-22743-7 · Cited by 241
Younan, Y., Deffieux, T., Larrat, B., Fink, M., Tanter, M., & Aubry, J.-F. (2013) · Medical Physics · doi:10.1118/1.4812423 · Cited by 204
Self-citationSimulation techniques in hyperthermia treatment planning
Paulides, M. M., Stauffer, P. R., Neufeld, E., Maccarini, P. F., Kyriakou, A., Canters, R. A. M., Diederich, C. J., Bakker, J. F., & Van Rhoon, G. C. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.790092 · Cited by 199
“Usually the pressure and temperature generated by actual transducers in the presence of acoustically characterised tissue (skull [95,96] and bovine femur [97–99]), man-made samples [100,101], or phantoms [102], was measured using movable hydrophone and/or thermocouples and compared to numerical results.”
di Biase, L., Falato, E., & Di Lazzaro, V. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00549 · Cited by 166
Numerical evaluation of the skull for human neuromodulation with transcranial focused ultrasound
Mueller, J. K., Ai, L., Bansal, P., & Legon, W. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa843e · Cited by 161
“Acoustic parameters were calculated from CT data assuming a linear relationship between skull porosity and the acoustic parameters [12, 26].”
BackgroundMethodInfluential
Metadata
- Authors
- Marquet, F., Pernot, M., Aubry, J.-F., Montaldo, G., Marsac, L., Tanter, M., & Fink, M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-04-08
- Volume
- 54
- Issue
- 9
- Pages
- 2597-2613
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2169057357
- Cited by
- 222
- References
- 22
- FWCI
- 5.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.