Quality control and assurance in functional near infrared spectroscopy (fNIRS) experimentation
Open accessThe DOI matches its Crossref record; 120 of the 120 references it cites were found in a registry or an index.
Abstract
Functional near infrared spectroscopy (fNIRS) is a rapidly developing neuroimaging modality for exploring cortical brain behaviour. Despite recent advances, the quality of fNIRS experimentation may be compromised in several ways: firstly, by altering the optical properties of the tissues encountered in the path of light; secondly, through adulteration of the recovered biological signals (noise) and finally, by modulating neural activity. Currently, there is no systematic way to guide the researcher regarding these factors when planning fNIRS studies. Conclusions extracted from fNIRS data will only be robust if appropriate methodology and analysis in accordance with the research question under investigation are employed. In order to address these issues and facilitate the quality control process, a taxonomy of factors influencing fNIRS data have been established. For each factor, a detailed description is provided and previous solutions are reviewed. Finally, a series of evidence-based recommendations are made with the aim of improving consistency and quality of fNIRS research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The assessment and analysis of handedness: The Edinburgh inventory
Oldfield, R. C. (1971) · Neuropsychologia · doi:10.1016/0028-3932(71)90067-4 · Cited by 35,900 · cited 1×
“Extra-cranial contributions to the signal affecting the optical pathlength include aspects of variable anatomy (tissue and skull thickness) and the presence and colour of hair (Okada and Delpy 2003b, Strangman et al 2002)—scalp blood flow is considered part of the systemic effect.”
BackgroundEstimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245 · cited 6×
“• Physiological interference must be eliminated, reduced or incorporated as confounder during analysis Extra-cranial Scalp blood flux, scalp and skull thickness, hair Intra-cranial Dura mater, arachnoid, CSF and pia mater Study design and data analysis Protocol design • Generic: randomization, assumption checking, non…”
BackgroundMethodInfluentialHomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817 · cited 11×
“Huppert et al (2009) recommend eliminating instrumental noise before conversion of light to haemodynamic data so the error does not propagate.”
BackgroundMethodInfluentialNon-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618 · cited 2×
“Infrared light can only penetrate up to 8 cm in neonates (Wyatt et al 1990) and 7 cm for adults (Villringer and Chance 1997).”
BackgroundInfluentialJurcak, V., Tsuzuki, D., & Dan, I. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.024 · Cited by 1,489 · cited 1×
“Typically, optodes are guided into position using the International 10/20 system for optode placement or an equally valid alternative reference in which more cranial positions are defined such as the UI 10/10 or 10/5 systems (Jurcak et al 2007).”
MethodOkamoto, M., Dan, H., Sakamoto, K., Takeo, K., Shimizu, K., Kohno, S., Oda, I., Isobe, S., Suzuki, T., Kohyama, K., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.026 · Cited by 1,320 · cited 2×
“The current gold standard is co-registration with magnetic resonance anatomical data, which involves placing fiducial markers such as fatty pine nuts (Okamoto et al., 2004), vitamin capsules (Hatakenaka et al.”
BackgroundNIRS-SPM: Statistical parametric mapping for near-infrared spectroscopy
YE, J., TAK, S., JANG, K., JUNG, J., & JANG, J. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.036 · Cited by 1,180
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065 · cited 2×
“Solutions incorporated into devices to reduce contamination by ambient light include the use of long pass filters (Cope and Delpy 1988), lock-in amplifiers (Coyle et al 2004), differential detection (Lee 2004) and embedding sensors in foam (Bozkurt et al 2005).”
BackgroundMethodNon-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903 · cited 4×
“De facto standard processing of fNIRS signals includes low-pass or band pass filtering to remove instrumentation noise, detrending to eliminate system drift and averaging across trials to increase SNR (Huppert et al 2009, Lloyd-Fox et al 2009).”
BackgroundInfluentialLloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865 · cited 13×
“The block design is more efficient for detecting differences between stimuli because it maximizes the predictor variance although is more affected by physiological noise and anticipation (Lloyd-Fox et al 2009, Nakano et al 2008, Morinaga et al 2007).”
BackgroundInfluential
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“, 2011), and the quality control in fNIRS studies (Orihuela-Espina et al., 2010).”
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Leff, D. R., Orihuela-Espina, F., Elwell, C. E., Athanasiou, T., Delpy, D. T., Darzi, A. W., & Yang, G.-Z. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.058 · Cited by 484
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Quaresima, V., & Ferrari, M. (2019) · Organizational Research Methods · doi:10.1177/1094428116658959 · Cited by 419
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Yamada, T., Umeyama, S., & Matsuda, K. (2012) · PLoS ONE · doi:10.1371/journal.pone.0050271 · Cited by 218
“Task-evoked systemic fluctuations can be reduced by a welldesigned task [16].”
BackgroundPfeifer, M. D., Scholkmann, F., & Labruyère, R. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00641 · Cited by 173
“…due to neurovascular coupling (Saager et al., 2011; Takahashi et al., 2011; Kirilina et al., 2012; Yamada et al., 2012; Gagnon et al., 2014; Tachtsidis and Scholkmann, 2016), and some were even specifically addressed to researchers new to the field (Orihuela-Espina et al., 2010; Leff et al., 2011).”
BackgroundKohl, S. H., Mehler, D. M. A., Lührs, M., Thibault, R. T., Konrad, K., & Sorger, B. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00594 · Cited by 161
“The SNR is dependent on individual physical features such as individual brain anatomy, head size, skull thickness, and hair properties (e.g., thickness, density, length and color; Orihuela-Espina et al., 2010).”
Background
Metadata
- Authors
- Orihuela-Espina, F., Leff, D. R., James, D. R. C., Darzi, A. W., & Yang, G. Z.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-06-09
- Volume
- 55
- Issue
- 13
- Pages
- 3701-3724
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2042855056
- Cited by
- 164
- References
- 120
- FWCI
- 4.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.