The impact of standing wave effects on transcranial focused ultrasound disruption of the blood–brain barrier in a rat model
Open accessThe DOI matches its Crossref record.
Abstract
Microbubble-mediated disruption of the blood-brain barrier (BBB) for targeted drug delivery using focused ultrasound shows great potential as a therapy for a wide range of brain disorders. This technique is currently at the pre-clinical stage and important work is being conducted in animal models. Measurements of standing waves in ex vivo rat skulls were conducted using an optical hydrophone and a geometry dependence was identified. Standing waves could not be eliminated through the use of swept frequencies, which have been suggested to eliminate standing waves. Definitive standing wave patterns were detected in over 25% of animals used in a single study. Standing waves were successfully eliminated using a wideband composite sharply focused transducer and a reduced duty cycle. The modified pulse parameters were used in vivo to disrupt the BBB in a rat indicating that, unlike some other bioeffects, BBB disruption is not dependent on standing wave conditions. Due to the high variability of standing waves and the inability to correctly estimate in situ pressures given standing wave conditions, attempts to minimize standing waves should be made in all future work in this field to ensure that results are clinically translatable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Clinical trial of blood-brain barrier disruption by pulsed ultrasound
Carpentier, A., Canney, M., Vignot, A., Reina, V., Beccaria, K., Horodyckid, C., Karachi, C., Leclercq, D., Lafon, C., Chapelon, J.-Y., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6086 · Cited by 757
“The differences between the observation in the clinical study and the preclinical experiments on the tolerated acoustic pressure before the appearance of adverse effects could be related to the size of the human skull, which limits standing waves relative to smaller animal models (22).”
BackgroundYoo, S., Mittelstein, D. R., Hurt, R. C., Lacroix, J., & Shapiro, M. G. (2022) · Nature Communications · doi:10.1038/s41467-022-28040-1 · Cited by 492
Aryal, M., Arvanitis, C. D., Alexander, P. M., & McDannold, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.01.008 · Cited by 443
Crossing the Blood–Brain Barrier: Recent Advances in Drug Delivery to the Brain
Patel, M. M., & Patel, B. M. (2017) · CNS Drugs · doi:10.1007/s40263-016-0405-9 · Cited by 430
Progress in brain targeting drug delivery system by nasal route
Khan, A. R., Liu, M., Khan, M. W., & Zhai, G. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.09.001 · Cited by 402
“These bubbles were administered systemically and worked on acoustic energy principle to exert pressure on endothelial cells and open the tight junctions, resulted in increased permeability of BBB and improved delivery of drug to the brain [25].”
BackgroundO’Reilly, M. A., & Hynynen, K. (2012) · Radiology · doi:10.1148/radiol.11111417 · Cited by 401
Self-citationNon-invasive transcranial ultrasound stimulation for neuromodulation
Darmani, G., Bergmann, T. O., Butts Pauly, K., Caskey, C. F., de Lecea, L., Fomenko, A., Fouragnan, E., Legon, W., Murphy, K. R., Nandi, T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.12.010 · Cited by 332
Ultrasonic Neuromodulation Causes Widespread Cortical Activation via an Indirect Auditory Mechanism
Sato, T., Shapiro, M. G., & Tsao, D. Y. (2018) · Neuron · doi:10.1016/j.neuron.2018.05.009 · Cited by 329
Sun, T., Zhang, Y., Power, C., Alexander, P. M., Sutton, J. T., Aryal, M., Vykhodtseva, N., Miller, E. L., & McDannold, N. J. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1713328114 · Cited by 258
Ultrasound Technologies for Imaging and Modulating Neural Activity
Rabut, C., Yoo, S., Hurt, R. C., Jin, Z., Li, H., Guo, H., Ling, B., & Shapiro, M. G. (2020) · Neuron · doi:10.1016/j.neuron.2020.09.003 · Cited by 249
“Given the small size of rodent heads relative to the FUS beam and the ms-scale pulse durations used in UNM, some lack of spatial specificity could arise from the formation of standing waves due to multiple reflections of ultrasound inside the skull (O’Reilly et al., 2010; Pulkkinen et al., 2014).”
BackgroundPark, J., Zhang, Y., Vykhodtseva, N., Jolesz, F. A., & McDannold, N. J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.06.012 · Cited by 217
“The large variation that was observed here was likely due to differences in skull thickness [39] and angle of incidence between the FUS beam and the skull surface for the different targets, and to the presence of standing waves within the intact skull cavity [40].”
Younan, Y., Deffieux, T., Larrat, B., Fink, M., Tanter, M., & Aubry, J.-F. (2013) · Medical Physics · doi:10.1118/1.4812423 · Cited by 204
Thévenot, E., Jordão, J. F., O'Reilly, M. A., Markham, K., Weng, Y.-Q., Foust, K. D., Kaspar, B. K., Hynynen, K., & Aubert, I. (2012) · Human Gene Therapy · doi:10.1089/hum.2012.013 · Cited by 202
“…of the right hemisphere and treated at 1.18 MHz, 0.53–0.6 MPa using a pulse sequence (10-msec bursts composed of single excitation cycles separated by 6-lsec delays, 1-Hz burst repetition frequency, 120-sec duration) designed to eliminate standing waves in the skull cavity (O’Reilly et al., 2010).”
MethodSelf-citationTung, Y.-S., Vlachos, F., Feshitan, J. A., Borden, M. A., & Konofagou, E. E. (2011) · The Journal of the Acoustical Society of America · doi:10.1121/1.3646905 · Cited by 200
Marty, B., Larrat, B., Van Landeghem, M., Robic, C., Robert, P., Port, M., Le Bihan, D., Pernot, M., Tanter, M., Lethimonnier, F., et al. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.100 · Cited by 199
Elbaz, M., Ad-El, N., Chulanova, Y., Brier, D., Goldsmith, M., Bismuth, M., Brosque, A., Sher, D., Gutkin, A., Bar-On, D., et al. (2025) · doi:10.1101/2025.01.23.634427 · Cited by 43
Kumar, S., Yadav, A., Verma, R. K., Kumar, A., Gupta, P. K., & Shukla, R. (2025) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.5c00386 · Cited by 14
Metadata
- Authors
- O'Reilly, M. A., Huang, Y., & Hynynen, K.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2010-08-18
- Volume
- 55
- Issue
- 18
- Pages
- 5251-5267
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2094299440
- Cited by
- 136
- References
- 0
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.