Review and current status of SPECT scatter correction
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Detection of scattered gamma quanta degrades image contrast and quantitative accuracy of single-photon emission computed tomography (SPECT) imaging. This paper reviews methods to characterize and model scatter in SPECT and correct for its image degrading effects, both for clinical and small animal SPECT. Traditionally scatter correction methods were limited in accuracy, noise properties and/or generality and were not very widely applied. For small animal SPECT, these approximate methods of correction are often sufficient since the fraction of detected scattered photons is small. This contrasts with patient imaging where better accuracy can lead to significant improvement of image quality. As a result, over the last two decades, several new and improved scatter correction methods have been developed, although often at the cost of increased complexity and computation time. In concert with (i) the increasing number of energy windows on modern SPECT systems and (ii) excellent attenuation maps provided in SPECT/CT, some of these methods give new opportunities to remove degrading effects of scatter in both standard and complex situations and therefore are a gateway to highly quantitative single- and multi-tracer molecular imaging with improved noise properties. Widespread implementation of such scatter correction methods, however, still requires significant effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
EM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
A Method for Attenuation Correction in Radionuclide Computed Tomography
Chang, L.-T. (1978) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1978.4329385 · Cited by 1,297 · cited 1×
“Attenuation correction strategies include simple multiplicative correction based on knowledge of the attenuation coefficients and hence the average attenuation factor for photons originating from a given location (Chang 1978).”
BackgroundComparison and Evaluation of Retrospective Intermodality Brain Image Registration Techniques
West, J., Fitzpatrick, J. M., Wang, M. Y., Dawant, B. M., Maurer, C. R., Kessler, R. M., Maciunas, R. J., Barillot, C., Lemoine, D., Collignon, A., et al. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00007 · Cited by 884 · cited 1×
“Similar exercises have proven to be very effective in demonstrating optimal choice of registration algorithms (West et al 1997).”
BackgroundA practical method for position-dependent Compton-scatter correction in single photon emission CT
Ogawa, K., Harata, Y., Ichihara, T., Kubo, A., & Hashimoto, S. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97591 · Cited by 616 · cited 1×
“The more recent TEW approach (Ogawa et al 1991) is similar in many respects; however, it relies on relatively narrow energy windows placed close on either side of the photo-peak.”
BackgroundImproved SPECT quantification using compensation for scattered photons.
Jaszczak, R. J., Kl, G., Floyd, C. E., Harris, C. C., & Coleman, R. E. (1984) · PubMed · Cited by 555
A Monte Carlo program for the simulation of scintillation camera characteristics
Ljungberg, M., & Strand, S.-E. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90111-9 · Cited by 515
Nuyts, J., Dupont, P., Stroobants, S., Benninck, R., Mortelmans, L., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774167 · Cited by 362
Determination of the attenuation map in emission tomography.
Zaidi, H., & Hasegawa, B. H. (2003) · PubMed · Cited by 350
Ichihara, T., Ogawa, K., Motomura, N., Kubo, A., & Hashimoto, S. (1993) · PubMed · Cited by 318
Cited by
Redefining Radiology: A Review of Artificial Intelligence Integration in Medical Imaging
Najjar, R. (2023) · Diagnostics · doi:10.3390/diagnostics13172760 · Cited by 886
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Ljungberg, M., Celler, A., Konijnenberg, M. W., Eckerman, K. F., Dewaraja, Y. K., & Sjögreen-Gleisner, K. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159012 · Cited by 369
Time-of-flight PET data determine the attenuation sinogram up to a constant
Defrise, M., Rezaei, A., & Nuyts, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/885 · Cited by 234
Metadata
- Authors
- Hutton, B. F., Buvat, I., & Beekman, F. J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-06-23
- Volume
- 56
- Issue
- 14
- Pages
- R85-R112
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2086685554
- Cited by
- 217
- References
- 47
- FWCI
- 13.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.