GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
GATE (Geant4 Application for Emission Tomography) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. Dedicated to the modelling of planar scintigraphy, single photon emission computed tomography (SPECT) and positron emission tomography (PET) acquisitions, this platform is widely used to assist PET and SPECT research. A recent extension of this platform, released by the OpenGATE collaboration as GATE V6, now also enables modelling of x-ray computed tomography and radiation therapy experiments. This paper presents an overview of the main additions and improvements implemented in GATE since the publication of the initial GATE paper (Jan et al 2004 Phys. Med. Biol. 49 4543-61). This includes new models available in GATE to simulate optical and hadronic processes, novelties in modelling tracer, organ or detector motion, new options for speeding up GATE simulations, examples illustrating the use of GATE V6 in radiotherapy applications and CT simulations, and preliminary results regarding the validation of GATE V6 for radiation therapy applications. Upon completion of extensive validation studies, GATE is expected to become a valuable tool for simulations involving both radiotherapy and imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
BEAM: A Monte Carlo code to simulate radiotherapy treatment units
Rogers, D. W. O., Faddegon, B. A., Ding, G. X., Ma, C. ‐., We, J., & Mackie, T. R. (1995) · Medical Physics · doi:10.1118/1.597552 · Cited by 1,431
PENELOPE: A code system for Monte Carlo simulation of electron and photon transport
(2020) · Penelope · doi:10.1787/9d2cc3d5-en · Cited by 1,275
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Comments on ICRU Report No. 49: Stopping Powers and Ranges for Protons and Alpha Particles
Ziegler, J. F. (1999) · Radiation Research · doi:10.2307/3580097 · Cited by 616
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization
Krämer, M., Jäkel, O., Haberer, T., Kraft, G., Schardt, D., & Weber, U. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/313 · Cited by 505
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420
Peptide receptor imaging and therapy.
Kwekkeboom, D. J., Krenning, E. P., & de Jong, M. (2000) · PubMed · Cited by 330
Cited by
Allison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194
Sarrut, D., Bardiès, M., Boussion, N., Freud, N., Jan, S., Létang, J.-M., Loudos, G., Maigne, L., Marcatili, S., Mauxion, T., et al. (2014) · Medical Physics · doi:10.1118/1.4871617 · Cited by 573
Self-citationGreen Algorithms: Quantifying the Carbon Footprint of Computation
Lannelongue, L., Grealey, J., & Inouye, M. (2021) · Advanced Science · doi:10.1002/advs.202100707 · Cited by 543
Bernal, M. A., Bordage, M. C., Brown, J. M. C., Davídková, M., Delage, E., El Bitar, Z., Enger, S. A., Francis, Z., Guatelli, S., Ivanchenko, V. N., et al. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.10.087 · Cited by 536
Self-citationViolet, J., Jackson, P., Ferdinandus, J., Sandhu, S., Akhurst, T., Iravani, A., Kong, G., Kumar, A. R., Thang, S. P., Eu, P., et al. (2019) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.219352 · Cited by 504
Karakatsanis, N. A., Lodge, M. A., Tahari, A. K., Zhou, Y., Wahl, R. L., & Rahmim, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/20/7391 · Cited by 247
“Its ability to model time-dependent phenomena as well as its accurate description of all physics processes underlying emission tomography (Jan et al 2011) makes it an ideal solution for evaluation of PET/SPECT systems performance and optimization of acquisition protocols (Karakatsanis et al 2006,…”
BackgroundMerlin, T., Stute, S., Benoit, D., Bert, J., Carlier, T., Comtat, C., Filipovic, M., Lamare, F., & Visvikis, D. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aadac1 · Cited by 236
Self-citationPET Image Denoising Using a Deep Neural Network Through Fine Tuning
Gong, K., Guan, J., Liu, C.-C., & Qi, J. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2877644 · Cited by 234
“If simulation data were generated by a more accurate Monte Carlo simulation, such as GATE [37], the results of the phantom-only CNN might be improved.”
MethodRit, S., Vila Oliva, M., Brousmiche, S., Labarbe, R., Sarrut, D., & Sharp, G. C. (2014) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/489/1/012079 · Cited by 234
Self-citationVirtual clinical trials in medical imaging: a review
Abadi, E., Segars, W. P., Tsui, B. M. W., Kinahan, P. E., Bottenus, N., Frangi, A. F., Maidment, A., Lo, J., & Samei, E. (2020) · Journal of Medical Imaging · doi:10.1117/1.jmi.7.4.042805 · Cited by 224
Advanced Monte Carlo simulations of emission tomography imaging systems with GATE
Sarrut, D., Bała, M., Bardiès, M., Bert, J., Chauvin, M., Chatzipapas, K., Dupont, M., Etxebeste, A., M Fanchon, L., Jan, S., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abf276 · Cited by 204
Self-citationHatt, M., Lee, J. A., Schmidtlein, C. R., Naqa, I. E., Caldwell, C., De Bernardi, E., Lu, W., Das, S., Geets, X., Gregoire, V., et al. (2017) · Medical Physics · doi:10.1002/mp.12124 · Cited by 198
Self-citationArce, P., Bolst, D., Bordage, M. ‐., Brown, J. M. C., Cirrone, P., Cortés‐Giraldo, M. A., Cutajar, D., Cuttone, G., Desorgher, L., Dondero, P., et al. (2021) · Medical Physics · doi:10.1002/mp.14226 · Cited by 187
Self-citationvan Velden, F. H. P., Cheebsumon, P., Yaqub, M., Smit, E. F., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1845-6 · Cited by 182
Metadata
- Authors
- Jan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., Morel, C., Perrot, Y., Rehfeld, N., Sarrut, D., Schaart, D. R., Stute, S., Pietrzyk, U., Visvikis, D., Zahra, N., & Buvat, I.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2011-01-20
- Volume
- 56
- Issue
- 4
- Pages
- 881-901
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2116085429
- Cited by
- 794
- References
- 24
- FWCI
- 62.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.