Range uncertainties in proton therapy and the role of Monte Carlo simulations
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The main advantages of proton therapy are the reduced total energy deposited in the patient as compared to photon techniques and the finite range of the proton beam. The latter adds an additional degree of freedom to treatment planning. The range in tissue is associated with considerable uncertainties caused by imaging, patient setup, beam delivery and dose calculation. Reducing the uncertainties would allow a reduction of the treatment volume and thus allow a better utilization of the advantages of protons. This paper summarizes the role of Monte Carlo simulations when aiming at a reduction of range uncertainties in proton therapy. Differences in dose calculation when comparing Monte Carlo with analytical algorithms are analyzed as well as range uncertainties due to material constants and CT conversion. Range uncertainties due to biological effects and the role of Monte Carlo for in vivo range verification are discussed. Furthermore, the current range uncertainty recipes used at several proton therapy facilities are revisited. We conclude that a significant impact of Monte Carlo dose calculation can be expected in complex geometries where local range uncertainties due to multiple Coulomb scattering will reduce the accuracy of analytical algorithms. In these cases Monte Carlo techniques might reduce the range uncertainty by several mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
FLUKA: A Multi-Particle Transport Code
Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005) · doi:10.2172/877507 · Cited by 2,536
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Relative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Self-citationTOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
Self-citationThe calibration of CT Hounsfield units for radiotherapy treatment planning
Schneider, U., Pedroni, E., & Lomax, A. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/009 · Cited by 1,093
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Schneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Comments on ICRU Report No. 49: Stopping Powers and Ranges for Protons and Alpha Particles
Ziegler, J. F. (1999) · Radiation Research · doi:10.2307/3580097 · Cited by 616
Theoretical and experimental aspects of the energy loss of relativistic heavily ionizing particles
Ahlen, S. P. (1980) · Reviews of Modern Physics · doi:10.1103/revmodphys.52.121 · Cited by 583
Janni, J. (1982) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(82)90004-3 · Cited by 488
Parodi, K., Paganetti, H., Shih, H. A., Michaud, S., Loeffler, J. S., DeLaney, T. F., Liebsch, N. J., Munzenrider, J. E., Fischman, A. J., Knopf, A., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.01.063 · Cited by 409
Self-citationPhysics Settings for Using the Geant4 Toolkit in Proton Therapy
Zacharatou Jarlskog, C., & Paganetti, H. (2008) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.922816 · Cited by 216
Self-citationNuclear Data for Neutron and Proton Radiotherapy and for Radiation Protection
Schulte, R. W. (2001) · Radiation Research · doi:10.1667/0033-7587(2001)156[0223:]2.0.co;2 · Cited by 185
Compensating for heterogeneities in proton radiation therapy
Urie, M., Goitein, M., & Wagner, M. (1984) · Physics in Medicine and Biology · doi:10.1088/0031-9155/29/5/008 · Cited by 183
Degradation of the Bragg peak due to inhomogeneities
Urie, M. M., Goitein, M., Holley, W. R., & Chen, G. T. Y. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/1/001 · Cited by 123
Wouters, B. G., Lam, G. K. Y., Oelfke, U., et al. (1996) · Radiation Research · doi:10.2307/3579588 · Cited by 120
Energy loss of 70 MeV protons in elements
Bischel, H., & Hiraoka, T. (1992) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(92)95995-4 · Cited by 89
du Plessis, F. C. P., Willemse, C. A., Lötter, M. G., & Goedhals, L. (1998) · Medical Physics · doi:10.1118/1.598297 · Cited by 81
Collimator scatter and 2D dosimetry in small proton beams
van Luijk, P., Veld, A. A. V. ‘., Zelle, H. D., & Schippers, J. M. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/303 · Cited by 63
Physics-Related Epistemic Uncertainties in Proton Depth Dose Simulation
Pia, M. G., Begalli, M., Lechner, A., Quintieri, L., & Saracco, P. (2010) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2010.2060355 · Cited by 30
Proton radiation in the management of localized cancer
Paganetti, H., & Kooy, H. M. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.2 · Cited by 26
Self-citationBednarz, B. P., Lu, H., Engelsman, M., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/9/013 · Cited by 22
Cited by
TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140
Self-citationPaganetti, H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/22/r419 · Cited by 915
Self-citationImage-guided radiotherapy: from current concept to future perspectives
Jaffray, D. A. (2012) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.194 · Cited by 496
Contemporary radiotherapy: present and future
Chandra, R. A., Keane, F. K., Voncken, F. E. M., & Thomas, C. R. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00233-6 · Cited by 380
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Self-citation
Metadata
- Authors
- Paganetti, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-05-09
- Volume
- 57
- Issue
- 11
- Pages
- R99-R117
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1999189079
- Cited by
- 1,325
- References
- 23
- FWCI
- 45.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.