GPU-based fast Monte Carlo dose calculation for proton therapy
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Accurate radiation dose calculation is essential for successful proton radiotherapy. Monte Carlo (MC) simulation is considered to be the most accurate method. However, the long computation time limits it from routine clinical applications. Recently, graphics processing units (GPUs) have been widely used to accelerate computationally intensive tasks in radiotherapy. We have developed a fast MC dose calculation package, gPMC, for proton dose calculation on a GPU. In gPMC, proton transport is modeled by the class II condensed history simulation scheme with a continuous slowing down approximation. Ionization, elastic and inelastic proton nucleus interactions are considered. Energy straggling and multiple scattering are modeled. Secondary electrons are not transported and their energies are locally deposited. After an inelastic nuclear interaction event, a variety of products are generated using an empirical model. Among them, charged nuclear fragments are terminated with energy locally deposited. Secondary protons are stored in a stack and transported after finishing transport of the primary protons, while secondary neutral particles are neglected. gPMC is implemented on the GPU under the CUDA platform. We have validated gPMC using the TOPAS/Geant4 MC code as the gold standard. For various cases including homogeneous and inhomogeneous phantoms as well as a patient case, good agreements between gPMC and TOPAS/Geant4 are observed. The gamma passing rate for the 2%/2 mm criterion is over 98.7% in the region with dose greater than 10% maximum dose in all cases, excluding low-density air regions. With gPMC it takes only 6-22 s to simulate 10 million source protons to achieve ∼1% relative statistical uncertainty, depending on the phantoms and energy. This is an extremely high efficiency compared to the computational time of tens of CPU hours for TOPAS/Geant4. Our fast GPU-based code can thus facilitate the routine use of MC dose calculation in proton therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106 · cited 9×
“Simulations in various phantom cases and in a patient case indicate that gPMC leads to dose calculation results that are in good agreement with that of TOPAS, which is based on the popular Geant4 code.”
MethodInfluentialEidelman, S., Hayes, K. G., Olive, K. A., Aguilar-Benitez, M., Amsler, C., Asner, D., Babu, K. S., Barnett, R. M., Beringer, J., Burchat, P. R., et al. (2004) · Physics Letters B · doi:10.1016/j.physletb.2004.06.001 · Cited by 6,673
Particle Data Group, Workman, R. L., Burkert, V. D., Crede, V, Klempt, E., Thoma, U., Tiator, L., Agashe, K., Aielli, G., Allanach, B. C., et al. (2022) · Progress of Theoretical and Experimental Physics · doi:10.1093/ptep/ptac097 · Cited by 5,964
Yost, G. P., Barnett, R. M., Hinchliffe, I., Lynch, G. R., Rittenberg, A., Ross, R. R., Suzuki, M., Trippe, T. G., Wohl, C. G., Armstrong, B., et al. (1988) · Physics Letters B · doi:10.1016/0370-2693(88)90505-9 · Cited by 4,399
Hagiwara, K., Hikasa, K., Nakamura, K., Tanabashi, M., Aguilar-Benitez, M., Amsler, C., Barnett, R. M., Burchat, P. R., Carone, C. D., Caso, C., et al. (2002) · Physical Review D · doi:10.1103/physrevd.66.010001 · Cited by 3,099
A technique for the quantitative evaluation of dose distributions
Low, D. A., Harms, W. B., Mutic, S., & Purdy, J. A. (1998) · Medical Physics · doi:10.1118/1.598248 · Cited by 2,880 · cited 1×
“The results are quantitatively measured using a γ -test (Low et al 1998).”
MethodRelative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Self-citationRange uncertainties in proton therapy and the role of Monte Carlo simulations
Paganetti, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/r99 · Cited by 1,325 · cited 1×
“Consequently, Monte Carlo (MC) dose calculation is desirable and it has been demonstrated that the use of MC in proton therapy could lead to a significant reduction in treatment planning margins (Paganetti 2012).”
MethodSelf-citationPENELOPE: A code system for Monte Carlo simulation of electron and photon transport
(2020) · Penelope · doi:10.1787/9d2cc3d5-en · Cited by 1,275
TOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140 · cited 15×
“We then measure the agreements between the gPMC result and the TOPAS result using a γ -test.”
MethodInfluentialSelf-citationTestU01: A C library for empirical testing of random number generators
L'Ecuyer, P., & Simard, R. (2007) · ACM Transactions on Mathematical Software · doi:10.1145/1268776.1268777 · Cited by 1,014 · cited 1×
“The quality of the random numbers has been tested using the TestU01 ‘Crush’ framework of tests (L’Ecuyer and Simard 2007).”
MethodKawrakow, I. (2000) · Medical Physics · doi:10.1118/1.598917 · Cited by 945 · cited 2×
“The physics employed by gPMC combines those reported in various publications (Kawrakow 2000, Fippel and Soukup 2004, Salvat et al 2009, Geant4 Collaboration 2011).”
MethodSchneider, W., Bortfeld, T., & Schlegel, W. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/314 · Cited by 831
Nuclear Energy Agency (2015) · PENELOPE: A code system for Monte Carlo simulation of electron and photon transport · doi:10.1787/4e3f14db-en · Cited by 534
Badal, A., & Badano, A. (2009) · Medical Physics · doi:10.1118/1.3231824 · Cited by 358 · cited 1×
“Kilo-voltage photon dose calculation packages also become available to assess CT dose to patients (Badal and Badano 2009, Jia et al 2012).”
BackgroundClinical implementation of full Monte Carlo dose calculation in proton beam therapy
Paganetti, H., Jiang, H., Parodi, K., Slopsema, R. L., & Engelsman, M. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/023 · Cited by 305 · cited 1×
“MC dose calculation has been introduced into proton clinics but it is applied only for re-calculating existing treatment plans for research studies, because it is still too computationally inefficient for routine applications for all patients (Paganetti et al 2008).”
MethodSelf-citationGPU computing in medical physics: A review
Pratx, G., & Xing, L. (2011) · Medical Physics · doi:10.1118/1.3578605 · Cited by 300 · cited 1×
“…perspective, it is not straightforward to achieve high performance in MC particle transport on a GPU platform (Hissoiny et al 2011, Jia et al 2011, Pratx and Xing 2011) because of the inherent conflict between the GPU’s SIMD (single instruction multiple data) processing scheme and the stochastic…”
BackgroundTime-frequency analysis using NVIDIA compute unified device architecture (CUDA)
Kulpa, J. (2009) · SPIE Proceedings · doi:10.1117/12.837990 · Cited by 256
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
Xu, F., & Mueller, K. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.851398 · Cited by 252 · cited 1×
“…(GPUs) have drawn great attention due to their tremendous ability of accelerating a variety of computationally intensive tasks in radiation therapy (Xu and Mueller 2005, Sharp et al 2007, Jacques et al 2008, Samant et al 2008, Yan et al 2008, Gu et al 2009, 2010, Hissoiny et al 2009, Men et al…”
BackgroundImplementation and evaluation of various demons deformable image registration algorithms on a GPU
Gu, X., Pan, H., Liang, Y., Castillo, R., Yang, D., Choi, D., Castillo, E., Majumdar, A., Guerrero, T., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/012 · Cited by 243
Self-citationJia, X., Lou, Y., Li, R., Song, W. Y., & Jiang, S. B. (2010) · Medical Physics · doi:10.1118/1.3371691 · Cited by 232
Self-citationGPUMCD: A new GPU‐oriented Monte Carlo dose calculation platform
Hissoiny, S., Ozell, B., Bouchard, H., & Després, P. (2011) · Medical Physics · doi:10.1118/1.3539725 · Cited by 219 · cited 2×
“In particular, a set of MC packages has been successfully developed for mega-voltage photon dose calculations and high acceleration factors have been reported (Jia et al 2010a, 2011, Hissoiny et al 2011, Jahnke et al 2012).”
BackgroundMethodSharp, G. C., Kandasamy, N., Singh, H., & Folkert, M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/19/003 · Cited by 190 · cited 1×
“…attention due to their tremendous ability of accelerating a variety of computationally intensive tasks in radiation therapy (Xu and Mueller 2005, Sharp et al 2007, Jacques et al 2008, Samant et al 2008, Yan et al 2008, Gu et al 2009, 2010, Hissoiny et al 2009, Men et al 2009, 2010a, 2010b, Jia…”
BackgroundGPU-based fast Monte Carlo simulation for radiotherapy dose calculation
Jia, X., Gu, X., Graves, Y. J., Folkerts, M., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/22/002 · Cited by 185 · cited 5×
“…computational perspective, it is not straightforward to achieve high performance in MC particle transport on a GPU platform (Hissoiny et al 2011, Jia et al 2011, Pratx and Xing 2011) because of the inherent conflict between the GPU’s SIMD (single instruction multiple data) processing scheme and…”
BackgroundMethodInfluentialSelf-citationDevelopment of a GPU-based Monte Carlo dose calculation code for coupled electron–photon transport
Jia, X., Gu, X., Sempau, J., Choi, D., Majumdar, A., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/11/006 · Cited by 151 · cited 2×
“In particular, a set of MC packages has been successfully developed for mega-voltage photon dose calculations and high acceleration factors have been reported (Jia et al 2010a, 2011, Hissoiny et al 2011, Jahnke et al 2012).”
BackgroundMethodSelf-citationFast cone-beam CT image reconstruction using GPU hardware
Yan, G., Tian, J., Zhu, S., Dai, Y., & Qin, C. (2008) · Journal of X-Ray Science and Technology · doi:10.3233/xst-2008-00205 · Cited by 129 · cited 1×
“…due to their tremendous ability of accelerating a variety of computationally intensive tasks in radiation therapy (Xu and Mueller 2005, Sharp et al 2007, Jacques et al 2008, Samant et al 2008, Yan et al 2008, Gu et al 2009, 2010, Hissoiny et al 2009, Men et al 2009, 2010a, 2010b, Jia et al 2010b).”
BackgroundSamant, S. S., Xia, J., Muyan-Özçelik, P., & Owens, J. D. (2008) · Medical Physics · doi:10.1118/1.2948318 · Cited by 119 · cited 1×
“…due to their tremendous ability of accelerating a variety of computationally intensive tasks in radiation therapy (Xu and Mueller 2005, Sharp et al 2007, Jacques et al 2008, Samant et al 2008, Yan et al 2008, Gu et al 2009, 2010, Hissoiny et al 2009, Men et al 2009, 2010a, 2010b, Jia et al 2010b).”
BackgroundGPU-based ultrafast IMRT plan optimization
Men, C., Gu, X., Choi, D., Majumdar, A., Zheng, Z., Mueller, K. D., & Jiang, S. B. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/21/008 · Cited by 115 · cited 1×
“…due to their tremendous ability of accelerating a variety of computationally intensive tasks in radiation therapy (Xu and Mueller 2005, Sharp et al 2007, Jacques et al 2008, Samant et al 2008, Yan et al 2008, Gu et al 2009, 2010, Hissoiny et al 2009, Men et al 2009, 2010a, 2010b, Jia et al 2010b).”
BackgroundSelf-citationFast Monte Carlo simulation for patient-specific CT/CBCT imaging dose calculation
Jia, X., Yan, H., Gu, X., & Jiang, S. B. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/3/577 · Cited by 94 · cited 1×
“Kilo-voltage photon dose calculation packages also become available to assess CT dose to patients (Badal and Badano 2009, Jia et al 2012).”
BackgroundSelf-citationGMC: a GPU implementation of a Monte Carlo dose calculation based on Geant4
Jahnke, L., Fleckenstein, J., Wenz, F. K., & Hesser, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/5/1217 · Cited by 87 · cited 1×
“In particular, a set of MC packages has been successfully developed for mega-voltage photon dose calculations and high acceleration factors have been reported (Jia et al 2010a, 2011, Hissoiny et al 2011, Jahnke et al 2012).”
MethodGPU-based ultra-fast dose calculation using a finite pencil beam model
Gu, X., Choi, D., Men, C., Pan, H. Y., Majumdar, A., & Jiang, S. B. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/20/017 · Cited by 86 · cited 1×
“…due to their tremendous ability of accelerating a variety of computationally intensive tasks in radiation therapy (Xu and Mueller 2005, Sharp et al 2007, Jacques et al 2008, Samant et al 2008, Yan et al 2008, Gu et al 2009, 2010, Hissoiny et al 2009, Men et al 2009, 2010a, 2010b, Jia et al 2010b).”
BackgroundSelf-citationGPU-based ultra-fast direct aperture optimization for online adaptive radiation therapy
Men, C., Jia, X., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/008 · Cited by 85
Self-citationUltrafast treatment plan optimization for volumetric modulated arc therapy (VMAT)
Men, C., Romeijn, H. E., Jia, X., & Jiang, S. B. (2010) · Medical Physics · doi:10.1118/1.3491675 · Cited by 80
Self-citationTowards real-time radiation therapy: GPU accelerated superposition/convolution
Jacques, R., Taylor, R. H., Wong, J. W., & McNutt, T. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.07.004 · Cited by 78
A GPU implementation of a track-repeating algorithm for proton radiotherapy dose calculations
Yepes, P. P., Mirković, D., & Taddei, P. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/23/s11 · Cited by 62 · cited 1×
“For the purpose of proton dose calculations, a track-repeating algorithm has been implemented on a GPU platform (Yepes et al 2010).”
MethodFast convolution‐superposition dose calculation on graphics hardware
Hissoiny, S., Ozell, B., & Després, P. (2009) · Medical Physics · doi:10.1118/1.3120286 · Cited by 58 · cited 1×
“…due to their tremendous ability of accelerating a variety of computationally intensive tasks in radiation therapy (Xu and Mueller 2005, Sharp et al 2007, Jacques et al 2008, Samant et al 2008, Yan et al 2008, Gu et al 2009, 2010, Hissoiny et al 2009, Men et al 2009, 2010a, 2010b, Jia et al 2010b).”
BackgroundGPU-based fast gamma index calculation
Gu, X., Jia, X., & Jiang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/5/014 · Cited by 49
Self-citationA particle track-repeating algorithm for proton beam dose calculation
Li, J. S., Shahine, B. H., Fourkal, E., et al. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/5/022 · Cited by 46 · cited 1×
“…the MC dose calculation process, such as using large-scale computational hardware and developing simplified algorithms (Kohno et al 2003, Fippel and Soukup 2004, Li et al 2005, Yepes et al 2009), the available proton MC dose calculation methods still cannot meet the clinically acceptable efficiency.”
MethodManagement of radon: a review of ICRP recommendations
Vaillant, L., & Bataillé, C. (2012) · Journal of Radiological Protection · doi:10.1088/0952-4746/32/3/r1 · Cited by 34
Cited by
Newhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Self-citation
Metadata
- Authors
- Jia, X., Schümann, J., Paganetti, H., & Jiang, S. B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-11-06
- Volume
- 57
- Issue
- 23
- Pages
- 7783-7797
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2015290878
- Cited by
- 177
- References
- 39
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.