STIR: software for tomographic image reconstruction release 2
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
We present a new version of STIR (Software for Tomographic Image Reconstruction), an open source object-oriented library implemented in C++ for 3D positron emission tomography reconstruction. This library has been designed such that it can be used for many algorithms and scanner geometries, while being portable to various computing platforms. This second release enhances its flexibility and modular design and includes additional features such as Compton scatter simulation, an additional iterative reconstruction algorithm and parametric image reconstruction (both indirect and direct). We discuss the new features in this release and present example results. STIR can be downloaded from http://stir.sourceforge.net.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1994) · Cited by 21,711
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Graphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567
Fast calculation of the exact radiological path for a three‐dimensional CT array
Siddon, R. L. (1985) · Medical Physics · doi:10.1118/1.595715 · Cited by 1,535
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
Analytic 3D image reconstruction using all detected events
Kinahan, P. E., & Rogers, J. G. (1989) · IEEE Transactions on Nuclear Science · doi:10.1109/23.34585 · Cited by 767
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
New, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Analytic and iterative reconstruction algorithms in SPECT.
Bruyant, P. P. (2002) · PubMed · Cited by 440
Cited by
Attenuation Correction Synthesis for Hybrid PET-MR Scanners: Application to Brain Studies
Burgos, N., Cardoso, M. J., Thielemans, K., Modat, M., Pedemonte, S., Dickson, J., Barnes, A., Ahmed, R., Mahoney, C. J., Schott, J. M., et al. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2340135 · Cited by 364
Self-citationKarakatsanis, N. A., Lodge, M. A., Tahari, A. K., Zhou, Y., Wahl, R. L., & Rahmim, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/20/7391 · Cited by 247
Merlin, T., Stute, S., Benoit, D., Bert, J., Carlier, T., Comtat, C., Filipovic, M., Lamare, F., & Visvikis, D. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aadac1 · Cited by 236
“For emission tomography, STIR (Thielemans et al 2012) is an Open Source software providing a Multi-Platform Object-Oriented framework for image reconstruction in PET and SPECT as well as for the estimation of data correction terms.”
MethodAdvanced Monte Carlo simulations of emission tomography imaging systems with GATE
Sarrut, D., Bała, M., Bardiès, M., Bert, J., Chauvin, M., Chatzipapas, K., Dupont, M., Etxebeste, A., M Fanchon, L., Jan, S., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abf276 · Cited by 204
Arce, P., Ignacio Lagares, J., Harkness, L., Pérez-Astudillo, D., Cañadas, M., Rato, P., de Prado, M., Abreu, Y., de Lorenzo, G., Kolstein, M., et al. (2014) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2013.09.036 · Cited by 159
“, and to dump the signals in a simple text of binary file or in a format compatible with the STIR [29] software.”
Method
Metadata
- Authors
- Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-01-31
- Volume
- 57
- Issue
- 4
- Pages
- 867-883
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2080500950
- Cited by
- 466
- References
- 33
- FWCI
- 27.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.