Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Magnetic particle imaging (MPI) is a new medical imaging approach that is based on the nonlinear magnetization response of super-paramagnetic iron oxide nanoparticles (SPIOs) injected into the blood stream. To date, real-time MPI of the bolus passage of an approved MRI SPIO contrast agent injected into the tail vein of living mice has been demonstrated. However, nanoparticles are rapidly removed from the blood stream by the mononuclear phagocyte system. Therefore, imaging applications for long-term monitoring require the repeated administration of bolus injections, which complicates quantitative comparisons due to the temporal variations in concentration. Encapsulation of SPIOs into red blood cells (RBCs) has been suggested to increase the blood circulation time of nanoparticles. This work presents first evidence that SPIO-loaded RBCs can be imaged in the blood pool of mice several hours after injection using MPI. This finding is supported by magnetic particle spectroscopy performed to quantify the iron concentration in blood samples extracted from the mice 3 and 24 h after injection of SPIO-loaded RBCs. Based on these results, new MPI applications can be envisioned, such as permanent 3D real-time visualization of the vessel tree during interventional procedures, bleeding monitoring after stroke, or long-term monitoring and treatment control of cardiovascular diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Self-citation
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Applications of nanoparticles in biomedical imaging
Han, X., Xu, K., Taratula, O., & Farsad, K. (2019) · Nanoscale · doi:10.1039/c8nr07769j · Cited by 637
Magnetic Nanoparticles in Cancer Therapy and Diagnosis
Farzin, A., Etesami, S. A., Quint, J., Memic, A., & Tamayol, A. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901058 · Cited by 562
Human-sized magnetic particle imaging for brain applications
Graeser, M., Thieben, F., Szwargulski, P., Werner, F., Gdaniec, N., Boberg, M., Griese, F., Möddel, M., Ludewig, P., van de Ven, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09704-x · Cited by 334
Self-citationMagnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“The first in vivo results presented by Weizenecker et al 7 as well as several other studies with dynamic images 23–25 have been reconstructed with dedicated system matrices (see Figure 3).”
Background
Metadata
- Authors
- Rahmer, J., Antonelli, A., Sfara, C., Tiemann, B., Gleich, B., Magnani, M., Weizenecker, J., & Borgert, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-05-17
- Volume
- 58
- Issue
- 12
- Pages
- 3965-3977
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2007933892
- Cited by
- 111
- References
- 1
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection. https://app.cochat.ai/papers/10.1088/0031-9155/58/12/3965
- The paper
- Rahmer, J., Antonelli, A., Sfara, C., Tiemann, B., Gleich, B., Magnani, M., Weizenecker, J., & Borgert, J. (2013). Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/58/12/3965
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.