Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Magnetic particle imaging (MPI) is a new medical imaging approach that is based on the nonlinear magnetization response of super-paramagnetic iron oxide nanoparticles (SPIOs) injected into the blood stream. To date, real-time MPI of the bolus passage of an approved MRI SPIO contrast agent injected into the tail vein of living mice has been demonstrated. However, nanoparticles are rapidly removed from the blood stream by the mononuclear phagocyte system. Therefore, imaging applications for long-term monitoring require the repeated administration of bolus injections, which complicates quantitative comparisons due to the temporal variations in concentration. Encapsulation of SPIOs into red blood cells (RBCs) has been suggested to increase the blood circulation time of nanoparticles. This work presents first evidence that SPIO-loaded RBCs can be imaged in the blood pool of mice several hours after injection using MPI. This finding is supported by magnetic particle spectroscopy performed to quantify the iron concentration in blood samples extracted from the mice 3 and 24 h after injection of SPIO-loaded RBCs. Based on these results, new MPI applications can be envisioned, such as permanent 3D real-time visualization of the vessel tree during interventional procedures, bleeding monitoring after stroke, or long-term monitoring and treatment control of cardiovascular diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Self-citation
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Applications of nanoparticles in biomedical imaging
Han, X., Xu, K., Taratula, O., & Farsad, K. (2019) · Nanoscale · doi:10.1039/c8nr07769j · Cited by 637
Magnetic Nanoparticles in Cancer Therapy and Diagnosis
Farzin, A., Etesami, S. A., Quint, J., Memic, A., & Tamayol, A. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901058 · Cited by 562
Human-sized magnetic particle imaging for brain applications
Graeser, M., Thieben, F., Szwargulski, P., Werner, F., Gdaniec, N., Boberg, M., Griese, F., Möddel, M., Ludewig, P., van de Ven, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09704-x · Cited by 334
Self-citationMagnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“The first in vivo results presented by Weizenecker et al 7 as well as several other studies with dynamic images 23–25 have been reconstructed with dedicated system matrices (see Figure 3).”
BackgroundZheng, B., Vazin, T., Goodwill, P. W., Conway, A., Verma, A., Ulku Saritas, E., Schaffer, D., & Conolly, S. M. (2015) · Scientific Reports · doi:10.1038/srep14055 · Cited by 274
Red blood cell membrane camouflaged magnetic nanoclusters for imaging-guided photothermal therapy
Ren, X., Zheng, R., Fang, X., Wang, X., Zhang, X., Yang, W., & Sha, X. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.03.026 · Cited by 260
Magnetic particle imaging: from proof of principle to preclinical applications
Knopp, T., Gdaniec, N., & Möddel, M. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa6c99 · Cited by 238
Superparamagnetic iron oxides as MPI tracers: A primer and review of early applications
Bulte, J. W. M. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.007 · Cited by 202
First experimental evidence of the feasibility of multi-color magnetic particle imaging
Rahmer, J., Halkola, A., Gleich, B., Schmale, I., & Borgert, J. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/5/1775 · Cited by 170
“…of MPI in cardiac interventions (Haegele et al 2012), it could be used to differentiate between a catheter (impregnated with immobilized particles (Rahmer et al 2013b)) and blood (free flowing particles or particles encapsulated in red blood cells (Antonelli et al 2011, Rahmer et al 2013a)).”
BackgroundSelf-citationDesign of superparamagnetic nanoparticles for magnetic particle imaging (MPI)
Du, Y., Lai, P., Leung, C., & Pong, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918682 · Cited by 81
“Some comparative blood volume measurements in vessel lumens can also benefit from the long-lasting homogeneous tracer concentration in blood [67].”
BackgroundInfluentialFirst in vivo traveling wave magnetic particle imaging of a beating mouse heart
Vogel, P., Rückert, M. A., Klauer, P., Kullmann, W. H., Jakob, P. M., & Behr, V. C. (2016) · Physics in Medicine & Biology · doi:10.1088/0031-9155/61/18/6620 · Cited by 60
Kaul, M., Weber, O., Heinen, U., Reitmeier, A., Mummert, T., Jung, C., Raabe, N., Knopp, T., Ittrich, H., & Adam, G. (2015) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-0034-1399344 · Cited by 42
“The previously reported prototype scanner had a selection field gradient strength of a maximum of 5.5T/m offering submillimeter resolutions [4, 11, 12].”
BackgroundRecent Advances in the Development of Magnetic Nanoparticles for Biomedical Applications
Monteserín, M., Larumbe, S., Martínez, A. V., Burgui, S., & Francisco Martín, L. (2021) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2021.19062 · Cited by 27
Metadata
- Authors
- Rahmer, J., Antonelli, A., Sfara, C., Tiemann, B., Gleich, B., Magnani, M., Weizenecker, J., & Borgert, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-05-17
- Volume
- 58
- Issue
- 12
- Pages
- 3965-3977
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2007933892
- Cited by
- 111
- References
- 1
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.