CoChat

In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT

Open access
Clark, Darin P, Ghaghada, Ketan, Moding, Everett J, Kirsch, David G, Badea, Cristian T · 2013 · Physics in Medicine and Biology
Cited by 127

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Tumor blood volume and vascular permeability are well established indicators of tumor angiogenesis and important predictors in cancer diagnosis, planning and treatment. In this work, we establish a novel preclinical imaging protocol which allows quantitative measurement of both metrics simultaneously. First, gold nanoparticles are injected and allowed to extravasate into the tumor, and then liposomal iodine nanoparticles are injected. Combining a previously optimized dual energy micro-CT scan using high-flux polychromatic x-ray sources (energies: 40 kVp, 80 kVp) with a novel post-reconstruction spectral filtration scheme, we are able to decompose the results into 3D iodine and gold maps, allowing simultaneous measurement of extravasated gold and intravascular iodine concentrations. Using a digital resolution phantom, the mean limits of detectability (mean CNR = 5) for each element are determined to be 2.3 mg mL(-1) (18 mM) for iodine and 1.0 mg mL(-1) (5.1 mM) for gold, well within the observed in vivo concentrations of each element (I: 0-24 mg mL(-1), Au: 0-9 mg mL(-1)) and a factor of 10 improvement over the limits without post-reconstruction spectral filtration. Using a calibration phantom, these limits are validated and an optimal sensitivity matrix for performing decomposition using our micro-CT system is derived. Finally, using a primary mouse model of soft-tissue sarcoma, we demonstrate the in vivo application of the protocol to measure fractional blood volume and vascular permeability over the course of five days of active tumor growth.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/58/6/1683

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 127

Metadata

Authors
Clark, D. P., Ghaghada, K., Moding, E. J., Kirsch, D. G., & Badea, C. T.
Venue
Physics in Medicine and Biology
Published
2013-02-19
Volume
58
Issue
6
Pages
1683-1704
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2036743656
Cited by
127
References
3
FWCI
7.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT. https://app.cochat.ai/papers/10.1088/0031-9155/58/6/1683
The paper
Clark, D. P., Ghaghada, K., Moding, E. J., Kirsch, D. G., & Badea, C. T. (2013). In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/58/6/1683

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.