In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Tumor blood volume and vascular permeability are well established indicators of tumor angiogenesis and important predictors in cancer diagnosis, planning and treatment. In this work, we establish a novel preclinical imaging protocol which allows quantitative measurement of both metrics simultaneously. First, gold nanoparticles are injected and allowed to extravasate into the tumor, and then liposomal iodine nanoparticles are injected. Combining a previously optimized dual energy micro-CT scan using high-flux polychromatic x-ray sources (energies: 40 kVp, 80 kVp) with a novel post-reconstruction spectral filtration scheme, we are able to decompose the results into 3D iodine and gold maps, allowing simultaneous measurement of extravasated gold and intravascular iodine concentrations. Using a digital resolution phantom, the mean limits of detectability (mean CNR = 5) for each element are determined to be 2.3 mg mL(-1) (18 mM) for iodine and 1.0 mg mL(-1) (5.1 mM) for gold, well within the observed in vivo concentrations of each element (I: 0-24 mg mL(-1), Au: 0-9 mg mL(-1)) and a factor of 10 improvement over the limits without post-reconstruction spectral filtration. Using a calibration phantom, these limits are validated and an optimal sensitivity matrix for performing decomposition using our micro-CT system is derived. Finally, using a primary mouse model of soft-tissue sarcoma, we demonstrate the in vivo application of the protocol to measure fractional blood volume and vascular permeability over the course of five days of active tumor growth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bilateral Filtering for Gray and Color Images
Tomasi, C., & Manduchi, R. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710815 · Cited by 8,177 · cited 2×
“‘Classic’ BF (Tomasi and Manduchi 1998) denoised the reconstructed volumes while conscientiously preserving edges by performing the following operation at each voxel:”
BackgroundMaeda, H. (2001) · Advances in Enzyme Regulation · doi:10.1016/s0065-2571(00)00013-3 · Cited by 2,495 · cited 1×
“We used the smaller AuNp (∼15 nm diameter), which begin to extravasate ∼45 min after injection, to measure tumor permeability by exploiting the Enhanced Permeation and Retention (EPR) effect (Maeda 2001).”
MethodAtherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
Cited by
A Plasmonic Gold Nanostar Theranostic Probe for In Vivo Tumor Imaging and Photothermal Therapy
Liu, Y., Ashton, J. R., Moding, E. J., Yuan, H., Register, J. K., Fales, A. M., Choi, J., Whitley, M. J., Zhao, X., Qi, Y., et al. (2015) · Theranostics · doi:10.7150/thno.11974 · Cited by 308
Self-citationRoadmap to Clinical Use of Gold Nanoparticles for Radiation Sensitization
Schuemann, J., Berbeco, R., Chithrani, D. B., Cho, S. H., Kumar, R., McMahon, S. J., Sridhar, S., & Krishnan, S. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.09.032 · Cited by 253
Micro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
“tumor vascular density and vessel permeability in soft-tissue sarcomas [165] and primary lung tumors [161].”
BackgroundMethodSelf-citationYeh, B. M., FitzGerald, P. F., Edic, P. M., Lambert, J. W., Colborn, R. E., Marino, M. E., Evans, P. M., Roberts, J. C., Wang, Z. J., Wong, M. J., et al. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.09.001 · Cited by 219
“Dual-energy micro-CT at 40 and 80 kVp allowed the signal from intravascular iodinated contrast agent in the liposomal blood pool to be separated from that of gold nanoparticles that had passively accumulated into sarcoma tissue [89] or into lung tumors [21].”
BackgroundTargeted nanotechnology for cancer imaging
Toy, R., Bauer, L., Hoimes, C., Ghaghada, K. B., & Karathanasis, E. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.08.002 · Cited by 192
“Due to their long circulation property and nano-size, these agents provide a more accurate measurement of fractional tumor blood volume and therefore could serve as a phenotypical biomarker to assess the efficacy of anti-angiogenic agents [225].”
Self-citation
Metadata
- Authors
- Clark, D. P., Ghaghada, K., Moding, E. J., Kirsch, D. G., & Badea, C. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-02-19
- Volume
- 58
- Issue
- 6
- Pages
- 1683-1704
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2036743656
- Cited by
- 127
- References
- 3
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT. https://app.cochat.ai/papers/10.1088/0031-9155/58/6/1683
- The paper
- Clark, D. P., Ghaghada, K., Moding, E. J., Kirsch, D. G., & Badea, C. T. (2013). In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/58/6/1683
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.