Development of a new generation of high-resolution anatomical models for medical device evaluation: the Virtual Population 3.0
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
The Virtual Family computational whole-body anatomical human models were originally developed for electromagnetic (EM) exposure evaluations, in particular to study how absorption of radiofrequency radiation from external sources depends on anatomy. However, the models immediately garnered much broader interest and are now applied by over 300 research groups, many from medical applications research fields. In a first step, the Virtual Family was expanded to the Virtual Population to provide considerably broader population coverage with the inclusion of models of both sexes ranging in age from 5 to 84 years old. Although these models have proven to be invaluable for EM dosimetry, it became evident that significantly enhanced models are needed for reliable effectiveness and safety evaluations of diagnostic and therapeutic applications, including medical implants safety. This paper describes the research and development performed to obtain anatomical models that meet the requirements necessary for medical implant safety assessment applications. These include implementation of quality control procedures, re-segmentation at higher resolution, more-consistent tissue assignments, enhanced surface processing and numerous anatomical refinements. Several tools were developed to enhance the functionality of the models, including discretization tools, posing tools to expand the posture space covered, and multiple morphing tools, e.g., to develop pathological models or variations of existing ones. A comprehensive tissue properties database was compiled to complement the library of models. The results are a set of anatomically independent, accurate, and detailed models with smooth, yet feature-rich and topologically conforming surfaces. The models are therefore suited for the creation of unstructured meshes, and the possible applications of the models are extended to a wider range of solvers and physics. The impact of these improvements is shown for the MRI exposure of an adult woman with an orthopedic spinal implant. Future developments include the functionalization of the models for specific physical and physiological modeling tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Each model is made up of over 300 tissues, with a supporting database of electromagnetic properties for each tissue.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The Virtual Population [30] is a set of human models for electromagnetic simulations that have been created for these purposes.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
The cited source says what the claim attributes to it.
In the citing paper
“MR-induced heating ISCTs using the virtual patients such as the Virtual Population [30] often focus validation efforts on the device model (e.g., clause 8.7.5 in ISO/TS 10974 [28]), rather than the patient model or coupled device-patient model.”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [30]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“The assignment of the dielectric tissue properties at 64 MHz was done according to the material database (see section 2.2.4), which includes work presented in Gabriel et al (1996), and all metallic parts of the coil and the implant were treated as perfect electrical conductors.”
MethodInfluentialde Onís, M., Onyango, A. W., Borghi, E., Siyam, A., Pinol, A., Garza, C., Martines, J., Martorell, R., Victora, C. G., Bhan, M. K., et al. (2006) · (2006) · Cited by 3,401
Lanczos Filtering in One and Two Dimensions
Duchon, C. E. (1979) · Journal of Applied Meteorology · doi:10.1175/1520-0450(1979)018<1016:lfioat>2.0.co;2 · Cited by 2,398 · cited 3×
“It was tuned with lumped elements placed at the end rings between the rungs to match previously performed measurements (Cabot et al 2013). Due to the high resolution required by the implant and the large simulation domain required by the birdcage coil, the computation was performed in two steps: the fields in the bird…”
MethodInfluentialEfficient Management of Parallelism in Object-Oriented Numerical Software Libraries
Balay, S., Gropp, W. D., McInnes, L. C., & Smith, B. F. (1997) · Modern Software Tools for Scientific Computing · doi:10.1007/978-1-4612-1986-6_8 · Cited by 2,009 · cited 1×
“Dedicated high performance computing-enabled solvers, based on the PETSc framework (Balay et al 1997), have been developed for this purpose.”
MethodReport of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Medical Image Computing and Computer-Assisted Intervention
Yang, G., Hawkes, D. J., Rueckert, D., Noble, J. A., & Taylor, C. (2009) · Research Explorer (The University of Manchester) · Cited by 1,591
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439 · cited 2×
“Pregnant women models at three gestational stages presented in Christ et al (2012) are included in the Virtual Population.”
BackgroundMethodSelf-citationComputerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Automatic three‐dimensional mesh generation by the finite octree technique
Shephard, M. S., & Georges, M. K. (1991) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.1620320406 · Cited by 732
amira: A Highly Interactive System for Visual Data Analysis
STALLING, D., WESTERHOFF, M., & HEGE, H.-C. (2005) · Visualization Handbook · doi:10.1016/b978-012387582-2/50040-x · Cited by 569 · cited 1×
“Also, the surface extraction and processing have been updated: previously, the surface extraction, simplification, and smoothing routines from the Amira software (Stalling et al 2005) were used.”
Method
Research works printed but not linked: 6
- Benkler S, Chavannes N and Kuster N 2009 New powerful FDTD source based on Huygens surface: highly complex EM simulations performed on an ordinary PC Abstract Collection of BioEM 2009 Davos: the Joint Meeting of the Bioelectromagnetics Society and the European BioElectromagnetics Association (Davos, Switzerland 14-19 June) (Poster presentation P-262 in Poster session 2: Theoretical and Practical Modeling (June 16)) pp 736-7
- Cherubini E, Chavannes N and Kuster N 2008 Realistic skeleton based deformation of high-resolution anatomical human models for electromagnetic simulation BEMS 2008: Abstracts of the 30th Annu. Meeting of the Bioelectromagnetics Society (San Diego, CA, USA, 9-12 June) pp 505-7 (Poster Presentation P-149 in Poster Session: Theoretical and Practical Modeling) (10 June))
- Cristy M 1980 Mathematical phantoms representing children of various ages for use in estimates of internal dose Oak Ridge National Laboratory Technical Report ORNL (Oak Ridge, TN: ORNL)
- Neufeld E, Szczerba D and Kuster N 2013b Mechanical simulation-based approach for realistic model shape and posture parametrization CP'13: 4th Int. Workshop on Computational Phantoms for Radiation Protection, Imaging and Radiotherapy (Zurich, 20-22 May) pp 14-5
- Sempé M, Pédron G and Roy-Pernot M-P 1979 Auxologie: méthode et séquences Théraplix (Paris: Theraplix)
- Spurway J F, 2004, ASUM Ultrasound Bull., 7, 15
Cited by
Xu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Self-citationPanych, L. P., & Madore, B. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25761 · Cited by 220
MRI‐Related Heating of Implants and Devices: A Review
Winter, L., Seifert, F. C., Zilberti, L., Murbach, M., & Ittermann, B. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27194 · Cited by 188
Morrison, T. M., Pathmanathan, P., Adwan, M., & Margerrison, E. (2018) · Frontiers in Medicine · doi:10.3389/fmed.2018.00241 · Cited by 186
“…mechanical activity in the heart (30); energy absorption in patients with deep-brain stimulators (31– 34), breast tissue expanders (35), in pregnant women and fetus during MRI exams (36); subthalamic nucleus (37), the breast (38), cancellous bone (39), the head (40) and whole body models (41, 42).”
BackgroundVirtual Human Models for Electromagnetic Studies and Their Applications
Makarov, S. N., Noetscher, G. M., Yanamadala, J., Piazza, M. W., Louie, S., Prokop, A., Nazarian, A., & Nummenmaa, A. R. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2722420 · Cited by 179
“[28],[29], [83]-[93] lists computational models of a pregnant woman and/or a fetus currently available for electromagnetic and radiological simulations.”
BackgroundMethodInfluentialOn-Body Low-Profile Textile Antenna With Artificial Magnetic Conductor
Alemaryeen, A., & Noghanian, S. (2019) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2019.2902632 · Cited by 164
Fiedler, T. M., Ladd, M. E., & Bitz, A. K. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.035 · Cited by 143
Creation and application of virtual patient cohorts of heart models
Niederer, S. A., Aboelkassem, Y., Cantwell, C. D., Corrado, C., Coveney, S., Cherry, E. M., Delhaas, T., Fenton, F. H., Panfilov, A. V., Pathmanathan, P., et al. (2020) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2019.0558 · Cited by 103
“The virtual population [89] is a set of virtual patients, covering a range of ages, BMIs and both sexes.”
BackgroundApplication of the 4-D XCAT Phantoms in Biomedical Imaging and Beyond
Segars, W. P., Tsui, B. M. W., Cai, J., Yin, F.-F., Fung, G. S. K., & Samei, E. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2738448 · Cited by 119
“other phantoms have also been developed for use within bioengineering, medical device design, and other fields [2]–[7].”
BackgroundFoerster, M., Thielens, A., Joseph, W., Eeftens, M., & Röösli, M. (2018) · Environmental Health Perspectives · doi:10.1289/ehp2427 · Cited by 113
“SAR values are determined using numeric simulations based on two adolescent human body models from the phantom “virtual population,” an 11-y-old girl (Billie) and a 14-y-old boy (Louis) (Gosselin et al. 2014).”
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
“1) Assessing the fidelity of extracted surfaces to the original segmentation or the distance between initially extracted surfaces and simplified surfaces [12].”
InfluentialSelf-citationMapping migraine to a common brain network
Burke, M. J., Joutsa, J., Cohen, A. L., Soussand, L., Cooke, D., Burstein, R., & Fox, M. (2019) · Brain · doi:10.1093/brain/awz405 · Cited by 104
The Internet of Bodies: A Systematic Survey on Propagation Characterization and Channel Modeling
Celik, A., Salama, K. N., & Eltawil, A. M. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3098028 · Cited by 98
(2006) · Bioelectromagnetics · doi:10.1002/(issn)1521-186x · Cited by 96
Noninvasive Internal Body Temperature Tracking With Near-Field Microwave Radiometry
Momenroodaki, P., Haines, W., Fromandi, M., & Popovic, Z. B. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2776952 · Cited by 93
Massey, J. W., & Yılmaz, A. E. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591444 · Cited by 93
“extracting isosurfaces for each organ from the segmented data [5],[6],[12].”
MethodInfluentialFagan, A. J., Bitz, A. K., Björkman‐Burtscher, I. M., Collins, C. M., Kimbrell, V., & Raaijmakers, A. J. E. (2020) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27319 · Cited by 89
“Thorough simulations include realistic representation of the specific RF coils used in practice when loaded with a variety of models of different human subjects located at different positions relative to the coil.(37,47,48) Simulation of SAR requires software capable of solving the Maxwell’s equations throughout reali…”
MethodKyriakou, A., Neufeld, E., Werner, B., Székely, G. J., & Kuster, N. (2015) · Journal of Therapeutic Ultrasound · doi:10.1186/s40349-015-0032-9 · Cited by 77
“Additional details about the Virtual Population project can be found in [30].”
BackgroundMethodSelf-citationCrumpling effects and specific absorption rates of flexible AMC integrated antennas
Alemaryeen, A., & Noghanian, S. (2018) · IET Microwaves Antennas & Propagation · doi:10.1049/iet-map.2017.0652 · Cited by 76
Davids, M., Guérin, B., Malzacher, M., Schad, L. R., & Wald, L. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-05493-9 · Cited by 70
Pregnant women models analyzed for RF exposure and temperature increase in 3T RF shimmed birdcages
Murbach, M., Neufeld, E., Samaras, T., Córcoles, J., Robb, F. J. L., Kainz, W., & Kuster, N. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26268 · Cited by 66
“The anatomical pregnant human model Ella (at 3, 7, and 9 months of gestation) from the Virtual Population (13,14) was evaluated in five z-axis positions (landmarks heart to groin) within generic two-port 3T body coils; a 1.”
MethodSelf-citationShah, I. A., & Yoo, H. (2019) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2019.2903844 · Cited by 65
“values for the maximum accepted-power level, the SAR results can be adjusted by scaling the results using the equation given in [21] and is expressed as”
MethodGarcia‐Pardo, C., Andreu, C., Fornés-Leal, A., Castelló-Palacios, S., Perez-Simbor, S., Barbi, M., Vallés‐Lluch, A., & Cardona, N. (2018) · IEEE Antennas and Propagation Magazine · doi:10.1109/map.2018.2818458 · Cited by 64
“5 [33], [82]”
Rodríguez, C. E. F., de Salles, Á. A. A., Sears, M., Morris, R. D., & Davis, D. L. (2018) · Environmental Research · doi:10.1016/j.envres.2018.05.013 · Cited by 63
Credibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
Clément, J., Gruetter, R., & İpek, Ö. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27808 · Cited by 61
Ashyap, A. Y. I., Raad, R., Tubbal, F., Khan, W. A., & Abulgasem, S. (2025) · IEEE Access · doi:10.1109/access.2025.3536525 · Cited by 59
“Human body model of (a) Ella [191], and (b) Human voxel model [129].”
Surrogate modeling based on resampled polynomial chaos expansions
Liu, Z., Lesselier, D., Sudret, B., & Wiart, J. (2020) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2020.107008 · Cited by 55
“36 m high), named as “Eartha”, from the Virtual Classroom [58], is standing inside a 4 × 3 × 2 m 3 room, which is equipped with a WLAN source operating at 2 .”
Progress in Understanding Radiofrequency Heating and Burn Injuries for Safer MR Imaging
Tang, M., & Yamamoto, T. (2022) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.rev.2021-0047 · Cited by 53
“5 mm(3) via re-segmentation.(108) In addition, pregnant models were developed for different pregnancy periods on the basis of a 26-year-old female model.”
MethodJimenez, H., Wang, M., Zimmerman, J. W., Pennison, M. J., Sharma, S., Surratt, T., Xu, Z., Brezovich, I. A., Absher, D., Myers, R., et al. (2019) · EBioMedicine · doi:10.1016/j.ebiom.2019.05.034 · Cited by 53
“Dosimetry simulation, performed with SEMCAD X, was based on the adult male anatomical model Duke (weight 73 kg) of the ‘Virtual Population’ [15].”
MethodMurbach, M., Neufeld, E., Cabot, E., Zastrow, E., Córcoles, J., Kainz, W., & Kuster, N. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25986 · Cited by 52
“Anatomical Models and Landmarks The evaluations were conducted with six anatomical human models: the children Billie, Louis, and Roberta; and the adults Duke, Fats, and Ella; all part of the Virtual Population (16,17).”
MethodSelf-citationSynthetic data in radiological imaging: current state and future outlook
Sizikova, E., Badal, A., Delfino, J. G., Lago, M. A., Nelson, B., Saharkhiz, N., Sahiner, B., Zamzmi, G., & Badano, A. G. (2024) · BJR|Artificial Intelligence · doi:10.1093/bjrai/ubae007 · Cited by 52
“As an example, x-ray projections of digital phantoms can be efficiently simulated using Siddon’s ray-tracing algorithm, which models x-rays as straight lines from the source to the center of each pixel.”
MethodCapogrosso, M., Gandar, J., Greiner, N., Moraud, E. M., Wenger, N., Shkorbatova, P., Musienko, P., Minev, I., Lacour, S., & Courtine, G. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa87a · Cited by 48
A human cerebral and cerebellar 8‐channel transceive RF dipole coil array at 7T
Clément, J., Gruetter, R., & İpek, Ö. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27476 · Cited by 51
“4 (ZMT AG, Switzerland) on a whole body human model, Duke (34) (Fig.”
BackgroundInfluentialArduino, A., Bottauscio, O., Chiampi, M., Giaccone, L., Liorni, I., Kuster, N., Zilberti, L., & Zucca, M. (2020) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2019.2954111 · Cited by 51
Self-citationSantis, V. D., Campi, T., Cruciani, S., Laakso, I., & Feliziani, M. (2018) · Energies · doi:10.3390/en11030684 · Cited by 50
“, ‘Duke’ and ‘Fats’) [19] are placed inside the car (driving position) or just in front of the front door (standing position).”
Models and Indicators to Assess Thermal Sensation Under Steady-State and Transient Conditions
Enescu, D. (2019) · Energies · doi:10.3390/en12050841 · Cited by 51
“Explicit models are based on the Finite Difference Method (FDM) or the Finite Element Method (FEM) representation of the body [207].”
MethodLiorni, I., Capstick, M. H., van Wel, L., Wiart, J., Joseph, W., Cardis, E., Guxens, M., Vermeulen, R. C. H., & Thielens, A. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa127 · Cited by 50
Serrallés, J. E. C., Lattanzi, R., Giannakopoulos, I. I., Zhang, B., Ianniello, C., Cloos, M. A., Polimeridis, A. G., White, J., Sodickson, D. K., & Daniel, L. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2907442 · Cited by 48
Shikhantsov, S., Thielens, A., Vermeeren, G., Tanghe, E., Demeester, P. M. A., Martens, L., Torfs, G., & Joseph, W. (2019) · IEEE Access · doi:10.1109/access.2019.2897921 · Cited by 47
Shah, I. A., Cho, Y., & Yoo, H. (2020) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2020.3023734 · Cited by 45
Extremely Low Frequency Electric and Magnetic Fields Exposure: Survey of Recent Findings
Bonato, M., Chiaramello, E., Parazzini, M., Gajšek, P., & Ravazzani, P. (2023) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2023.3268555 · Cited by 44
“As an example, the “Virtual Population” family by IT’IS foundation represents an optimal possibility of high-resolution whole-body computational models [48], [49].”
Method3D Free‐breathing multichannel absolute Mapping in the human body at 7T
Dietrich, S., Aigner, C. S., Kolbitsch, C., Mayer, J., Ludwig, J., Schmidt, S., Schaeffter, T., & Schmitter, S. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28602 · Cited by 41
3 T: the good, the bad and the ugly
Graves, M. J. (2021) · British Journal of Radiology · doi:10.1259/bjr.20210708 · Cited by 41
Lee, J. H., Kuhar, S., Seo, J.-H., Pasricha, P. J., & Mittal, R. (2022) · Physics of Fluids · doi:10.1063/5.0096877 · Cited by 41
PAEDIATRIC MESH-TYPE REFERENCE COMPUTATIONAL PHANTOMS
156, I. P., & Approved by the Commission in March 2023 (2024) · Annals of the ICRP · doi:10.1177/01466453231210649 · Cited by 40
Morris, R. D., Morgan, L. L., & Davis, D. L. (2015) · IEEE Access · doi:10.1109/access.2015.2478701 · Cited by 40
“safety of medical implants by relying on anatomically based models for persons of varying ages and sizes [68], [69].”
Massive MIMO Propagation Modeling With User-Induced Coupling Effects Using Ray-Tracing and FDTD
Shikhantsov, S., Thielens, A., Vermeeren, G., Demeester, P. M. A., Martens, L., Torfs, G., & Joseph, W. (2020) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2020.3000874 · Cited by 39
“1 heterogeneous Duke human phantom [11] (further referred as the phantom) as a human model.”
BackgroundSafeRPlan: Safe deep reinforcement learning for intraoperative planning of pedicle screw placement
Ao, Y., Esfandiari, H., Carrillo, F., Laux, C. J., As, Y., Li, R., Assche, K. V., Davoodi, A., Cavalcanti, N., Farshad, M., et al. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103345 · Cited by 38
3-D MRI-Based Electrical Properties Tomography Using the Volume Integral Equation Method
Hong, R., Li, S., Zhang, J., Zhang, Y., Liu, N., Yu, Z., & Liu, Q. H. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2725830 · Cited by 38
Safety Analysis of Medical Implants in the Human Head Exposed to a Wireless Power Transfer System
Shah, I. A., Basir, A., Cho, Y., & Yoo, H. (2022) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2022.3144468 · Cited by 37
Recent Advances and Future Perspective in Computational Bioelectromagnetics for Exposure Assessments
Diao, Y., Joseph, W., Poljak, D., Giaccone, L., Kodera, S., Laakso, I., Yamazaki, K., Li, K., Sasaki, K., Tanghe, E., et al. (2025) · Bioelectromagnetics · doi:10.1002/bem.70002 · Cited by 36
“Despite a few models based on computer ‐ aided design (CAD) offering the potential for resolution adjustments (Gosselin et al. 2014), their accuracy compared to the original resolution remains uncertain.”
Transcranial Magnetic Stimulation: Development of a Novel Deep-Brain Triple-Halo Coil
Rastogi, P., Lee, E. G., Hadimani, R. L., & Jiles, D. C. (2019) · IEEE Magnetics Letters · doi:10.1109/lmag.2019.2903993 · Cited by 36
Heating and Safety Concerns of the Radio-Frequency Field in MRI
Murbach, M., Zastrow, E., Neufeld, E., Cabot, E., Kainz, W., & Kuster, N. (2015) · Current Radiology Reports · doi:10.1007/s40134-015-0128-6 · Cited by 36
“high-resolution anatomical models such as the virtual population [9, 10].”
Self-citationKuhar, S., Lee, J. H., Seo, J.-H., Pasricha, P. J., & Mittal, R. (2022) · Physics of Fluids · doi:10.1063/5.0120933 · Cited by 35
Arduino, A., Bottauscio, O., Chiampi, M., & Zilberti, L. (2018) · Inverse Problems · doi:10.1088/1361-6420/aac536 · Cited by 33
“In the following, both a section of the head and a section of the abdomen of the anatomical human model Duke from the virtual family [48] are studied (figure 2), because of their very different geometrical structures and EPs.”
BackgroundMethodBirks, L. E., van Wel, L., Liorni, I., Pierotti, L., Guxens, M., Huss, A., Foerster, M., Capstick, M. H., Eeftens, M., Marroun, H. E., et al. (2020) · Environmental Research · doi:10.1016/j.envres.2020.110505 · Cited by 32
A Fetal Brain magnetic resonance Acquisition Numerical phantom (FaBiAN)
Lajous, H., Roy, C., Hilbert, T., de Dumast, P., Tourbier, S., Alemán‐Gómez, Y., Yerly, J., Yu, T. V., Kebiri, H., Payette, K., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-10335-4 · Cited by 31
Colella, M., Meo, S. D., Liberti, M., Pasian, M., & Apollonio, F. (2023) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2023.3267568 · Cited by 31
“As all the ViP models, it was obtained from MRI data of a healthy volunteer using a scanning resolution of 0.9 × 0.9 × 2 mm 3 in the torso and limbs [27].”
MethodResultInfluentialYanamadala, J., Noetscher, G. M., Rathi, V. K., -, S. K. M., Win, H. A., Tran, A. L., Jackson, X. J., Htet, A. T., Kozlov, M., Nazarian, A., et al. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319082 · Cited by 31
Iterative time-reversal for multi-frequency hyperthermia
Zanoli, M., & Trefná, H. D. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abd41a · Cited by 32
Full torso and limited-domain computer models for epicardial pulsed electric field ablation
González‐Suárez, A., Irastorza, R. M., Deane, S., O’Brien, B., O’Halloran, M., & Elahi, A. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106886 · Cited by 29
Garrett, D. C., & Fear, E. C. (2019) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2019.2911849 · Cited by 30
Metrology for Inductive Charging of Electric Vehicles (MICEV)
Zucca, M., Bottauscio, O., Harmon, S. A. C., Guilizzoni, R., Schilling, F., Schmidt, M., Ankarson, P., Bergsten, T., Tammi, K., Sainio, P., et al. (2019) · AEIT International Conference of Electrical and Electronic Technologies for Automotive (AEIT AUTOMOTIVE) · doi:10.23919/eeta.2019.8804498 · Cited by 29
“The Project Consortium has adopted the selection of highly detailed human anatomical phantoms belonging to the Virtual Population (ViP) developed by IT’IS Foundation [14].”
MethodSelf-citationFunctionalized anatomical models for EM-neuron Interaction modeling
Neufeld, E., Cassara, A. M., Montanaro, H., Kuster, N., & Kainz, W. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4390 · Cited by 29
“0) anatomical models (IT’IS 2015), a set of high resolution anatomical models generated based on MRI data from healthy volunteers (Christ et al 2010, Gosselin et al 2014) who were chosen to optimally represent the Caucasian population. The models distinguish over 300 different tissues and organs for which dielectric a…”
InfluentialSelf-citationDiefenbach, M. N., Ruschke, S., Eggers, H., Meineke, J., Rummeny, E. J., & Karampinos, D. C. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27097 · Cited by 29
“As more FIGURE 3 Similar to Figure 2: Simulation of the object-based fast field map estimation in the ankle with the numerical whole body susceptibility phantom based onDuke.(30) The object-based fast field map estimate is computed for three different head–feet coverages (HF1–HF3) of only the right leg”
MethodEvaluation of specific absorption rate and heating in children exposed to a 7T MRI head coil
Malik, S., Hand, J. W., Carmichael, D. W., & Hajnal, J. V. (2022) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29283 · Cited by 28
Imaging performance of a dedicated radiation transparent RF coil on a 1.0 Tesla inline MRI-linac
Liney, G. P., Dong, B., Ewald, W., Rai, R., Destruel, A., García‐Álvarez, R., Manton, D. J., Jelen, U., Zhang, K., Barton, M. B., et al. (2018) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aac813 · Cited by 28
Colella, M., Paffi, A., Santis, V. D., Apollonio, F., & Liberti, M. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abcde7 · Cited by 28
Innovative Wireless Charging System for Implantable Capsule Robots
Campi, T., Cruciani, S., Maradei, F., & Feliziani, M. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2021.3078846 · Cited by 28
“To calculate the maximum allowable currents in the excitation system (i.e., Ib and Ic = Ib/2) be comply with the E-field limit, a simulation was performed using a high resolution HBM [28], as shown in Fig.”
MethodInfluentialMulti-purpose VHP-female version 3.0 cross-platform computational human model
Yanamadala, J., Noetscher, G. M., Louie, S., Prokop, A., Kozlov, M., Nazarian, A., & Makarov, S. N. (2016) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2016.7481298 · Cited by 27
“x is a CAD derivative of the broadly used yet voxel-based Virtual Family of IT’IS Foundation [12].”
MethodTzirini, M., Roth, Y., Harmelech, T., Zibman, S., Pell, G. S., Kimiskidis, V. Κ., Tendler, A., Zangen, A., & Samaras, T. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263145 · Cited by 27
“145 (Duke, Ella, Thelonious) [25-26], and eight members of the Population Head Model (PHM)”
BackgroundTaguchi, K., Kodera, S., Hirata, A., & Kashiwa, T. (2022) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2022.3203576 · Cited by 27
“Except for a few models that are based on computer-aided design [7], [8], the resolution of the human body models is in the range of 2–3 mm, and their resolutions cannot be easily changed.”
BackgroundPeng, Z. M., Gao, N., Wu, B., Chen, Z., & Xu, X. G. (2022) · Journal of Radiation Protection and Research · doi:10.14407/jrpr.2021.00402 · Cited by 27
“A team from Switzerland reported the Virtual Family, which is a series of BREP-based phantoms used for electromagnetic exposure calculations using MR images [139, 140].”
Inda, A. J. G., Huang, S. Y., İmamoğlu, N., Qin, R., Yang, T., Chen, T., Yuan, Z., & Yu, W. (2022) · Diagnostics · doi:10.3390/diagnostics12112627 · Cited by 27
“The coil was loaded with a digital human phantom, “Ella” from the virtual population 3.0 [45].”
BackgroundMethodInfluentialWang, Y., Guo, R., Hu, W., Zheng, J., Wang, Q., Jiang, J., Kurpad, K. N., Kaula, N. F., Long, S. A., Chen, J., et al. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28967 · Cited by 27
Self-citationAn update on computational anthropomorphic anatomical models
Akhavanallaf, A., Fayad, H. J., Salimi, Y., Aly, A., Kharita, H. M., Naemi, H. A., & Zaidi, H. (2022) · Digital Health · doi:10.1177/20552076221111941 · Cited by 25
A Systematic Review of Computational Fluid Dynamics Models in the Stomach and Small Intestine
Palmada, N., Hosseini, S., Avci, R., Cater, J. E., Suresh, V., & Cheng, L. K. (2023) · Applied Sciences · doi:10.3390/app13106092 · Cited by 25
Noninvasive Electrical Stimulation Neuromodulation and Digital Brain Technology: A Review
Zhang, S., Qin, Y., Wang, J., Yu, Y., Wu, L., & Zhang, T. (2023) · Biomedicines · doi:10.3390/biomedicines11061513 · Cited by 25
“Integrated Digital Human model (Sim4Life) [88,89] Cortex, muscles, skeletons, etc.”
MethodChiaramello, E., Parazzini, M., Fiocchi, S., Ravazzani, P., & Wiart, J. (2018) · IEEE Journal of Electromagnetics RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2018.2825018 · Cited by 25
“The EMF fields expressed by SWE in the space were used to compute equivalent EMF sources on the boundaries of a Huygens Box [19] containing a high resolution 8-years female child model “Eartha” from the Virtual Classroom [20].”
Computational Modeling of Drug Dissolution in the Human Stomach
Seo, J. H., & Mittal, R. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.755997 · Cited by 25
Xiao, Z., Tan, C., & Dong, F. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac09c · Cited by 25
“A cross-section parallel to the canthomeatal line of the anatomical head model of Duke (Gosselin et al (2014)) was extracted as a 2D head model (figure 7).”
MethodA VR Environment for Human Anatomical Variation Education: Modeling, Visualization and Interaction
Zhang, N., Wang, H., Huang, T., Zhang, X., & Liao, H. (2022) · IEEE Transactions on Learning Technologies · doi:10.1109/tlt.2022.3227100 · Cited by 24
“In the past ten years, some research works [7], [31] have used the population-orientated simulation, considering factors such as gender, age, height, weight, BMI, etc.”
BackgroundGuérin, B., Iacono, M. I., Davids, M., Dougherty, D. D., Angelone, L. M., & Wald, L. L. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aafce8 · Cited by 24
Arduino, A., Bottauscio, O., Brühl, R., Chiampi, M., & Zilberti, L. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab5428 · Cited by 24
Investigation of assumptions underlying current safety guidelines on EM-induced nerve stimulation
Neufeld, E., Oikonomidis, I. V., Iacono, M. I., Angelone, L. M., Kainz, W., & Kuster, N. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4466 · Cited by 24
“0, (Christ et al 2010, Gosselin et al 2014, IT’IS 2015)) Ella model (derived from MRI image data of a healthy, 26 year old female volunteer) was functionalized with the sciatic nerve, a large, extended nerve that is subject to inhomogeneous exposure. The sciatic nerve can be easily traced, and sophisticated, realistic…”
MethodSelf-citationHuman Head Skin Thickness Modeling for Electromagnetic Dosimetry
Rashed, E. A., Gomez-Tames, J. D., & Hirata, A. (2019) · IEEE Access · doi:10.1109/access.2019.2904743 · Cited by 24
Bonato, M., Tognola, G., Benini, M., Gallucci, S., Chiaramello, E., Fiocchi, S., & Parazzini, M. (2022) · Sensors · doi:10.3390/s22176564 · Cited by 23
Xiao, Z., Tan, C., & Dong, F. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa7504 · Cited by 23
Liu, H., Zhao, S., Tan, C., & Dong, F. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2928022 · Cited by 23
Liorni, I., Bottauscio, O., Guilizzoni, R., Ankarson, P., Bruna, J., Fallahi, A., Harmon, S. A. C., & Zucca, M. (2020) · Sustainability · doi:10.3390/su12114573 · Cited by 23
“These models belong to the Virtual Population [23,24] (ViP, developed by the Foundation for Research on Information Technologies in Society (IT’IS), Switzerland) and represent a wide range of the population in terms of age, size, and weight.”
MethodInfluentialBellizzi, G. G., Sümser, K., VilasBoas‐Ribeiro, I., Curto, S., Drizdal, T., van Rhoon, G. C., Franckena, M., & Paulides, M. M. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1772996 · Cited by 22
Gökyar, S., Zhao, C., Ma, S. J., & Wang, D. J. J. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29797 · Cited by 21
Costa, F. P., Wiedenmann, B., Schöll, E., & Tuszyński, J. A. (2024) · Frontiers in Network Physiology · doi:10.3389/fnetp.2024.1483401 · Cited by 21
Tankaria, H. V., Jackson, X. J., Borwankar, R. M., Srichandhru, G. N. K., Tran, A. L., Yanamadala, J., Noetscher, G. M., Nazarian, A., Louie, S., & Makarov, S. N. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591173 · Cited by 21
“Numerical simulation of the electromagnetic and thermal response of the human body to different stimuli in MRI safety, electromagnetic tomography, and electromagnetic stimulation is currently limited by the availability of anatomically adequate and numerically efficient cross-platform computational models [1-5].”
BackgroundJudée, F., & Dufour, T. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab03b8 · Cited by 21
“The phantom selected for this work is referenced as DUKE and presents the following features: Male, 34 years, 1.77 m, 70.2 kg, BMI 22.4 kg/m² (Gosselin et al 2014).”
BackgroundMethodInfluentialBoehm, C., Sollmann, N., Meineke, J., Ruschke, S., Dieckmeyer, M., Weiss, K., Zimmer, C., Makowski, M. R., Baum, T. H., & Karampinos, D. C. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28903 · Cited by 21
Plumley, A., Watkins, L., Treder, M. S., Liebig, P. A., Murphy, K., & Kopanoğlu, E. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29132 · Cited by 21
Dahdouh, S., Varsier, N., Serrurier, A., la Plata, J.-P. D., Anquez, J., Angelini, E. D., Wiart, J., & Bloch, I. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/16/4583 · Cited by 21
Metadata
- Authors
- Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., Cherubini, E., Szczerba, D., Kainz, W., & Kuster, N.
- Affiliations
- ETH Zurich (CH)
- Foundation for Research on Information Technologies in Society (CH)
- United States Food and Drug Administration (US)
- Corresponding author
- Gosselin, Marie-Christine
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-08-21
- Volume
- 59
- Issue
- 18
- Pages
- 5287-5303
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2102862641
- Cited by
- 520
- References
- 52
- Citations by year
- 2026: 34 · 2025: 64 · 2024: 44 · 2023: 50 · 2022: 61 · 2021: 52 · 2020: 53 · 2019: 45 · 2018: 42 · 2017: 35 · 2016: 20 · 2015: 14 · 2014: 3
- FWCI
- 12.45
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- iopscience.iop.org/page/copyright (vor)
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- European Commission (FP7/2007, 282891)
- Eidgenössische Technische Hochschule Zürich
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Keywords
- virtual population, MRI safety, spinal implants, surface processing, electromagnetic dosimetry, radiofrequency exposure, unstructured grid
- MeSH terms
- Adolescent, Adult, Aged, Aged, 80 and over, Child, Child, Preschool, Computer Simulation, Equipment and Supplies, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Male, Middle Aged, Models, Anatomic, Models, Theoretical, Radiometry, Surface Properties, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.