Investigations of sensitivity and resolution of ECG and MCG in a realistically shaped thorax model
Open accessThe DOI matches its Crossref record; 57 of the 58 references it cites were found in a registry or an index.
Abstract
Solving the inverse problem of electrocardiography (ECG) and magnetocardiography (MCG) is often referred to as cardiac source imaging. Spatial properties of ECG and MCG as imaging systems are, however, not well known. In this modelling study, we investigate the sensitivity and point-spread function (PSF) of ECG, MCG, and combined ECG+MCG as a function of source position and orientation, globally around the ventricles: signal topographies are modelled using a realistically-shaped volume conductor model, and the inverse problem is solved using a distributed source model and linear source estimation with minimal use of prior information. The results show that the sensitivity depends not only on the modality but also on the location and orientation of the source and that the sensitivity distribution is clearly reflected in the PSF. MCG can better characterize tangential anterior sources (with respect to the heart surface), while ECG excels with normally-oriented and posterior sources. Compared to either modality used alone, the sensitivity of combined ECG+MCG is less dependent on source orientation per source location, leading to better source estimates. Thus, for maximal sensitivity and optimal source estimation, the electric and magnetic measurements should be combined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Indeed, a large body of literature has provided evidence that MCG enhances the non-invasive diagnostic and prognostic capability in numerous clinical fields, such as but not limited to the earlier detection of (sometimes electrically silent) myocardial ischemia (59, 88, 90, 323, 319), the preventive arrhythmogenic risk assessment in adults (53, 225, 325–322) as well as in fetuses (83, 323, 324),”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [324]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inverse Problem Theory and Methods for Model Parameter Estimation
Tarantola, A. (2005) · doi:10.1137/1.9780898717921 · Cited by 6,585
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995 · cited 1×
“00 © 2014 Institute of Physics and Engineering in Medicine Printed in the UK & the USA Phys. Med. Biol. 59 (2014) 7141–7158 doi:10.”
BackgroundBasic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Amann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Monte Carlo simulation studies of EEG and MEG localization accuracy
Liu, A. K., Dale, A. M., & Belliveau, J. W. (2002) · Human Brain Mapping · doi:10.1002/hbm.10024 · Cited by 349
Distributed current estimates using cortical orientation constraints
Lin, F., Belliveau, J. W., Dale, A. M., & Hämäläinen, M. S. (2006) · Human Brain Mapping · doi:10.1002/hbm.20155 · Cited by 289
Improving source reconstructions by combining bioelectric and biomagnetic data
Fuchs, M., Wagner, M., Wischmann, H.-A., Köhler, T., Theißen, A., Drenckhahn, R., & Buchner, H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00046-7 · Cited by 239
On the theory of the electrocardiogram
Geselowitz, D. B. (1989) · Proceedings of the IEEE · doi:10.1109/5.29327 · Cited by 224
Bioelectricity and biomagnetism
Gulrajani, R. M. (1998) · Cited by 217
Research works printed but not linked: 2
- Dössel O 2000 Inverse problem of electro-and magnetocardiography: review and recent progress Int. J. Bioelectromagn. 2 (www.ijbem.org/volume2/number2/doessel/paper_ijbem.htm) Phys. Med. Biol. 59 (2014) 7141
- Oostendorp T and Pesola K 2001 Non-invasive determination of the activation sequence of the heart based on combined ECG and MCG measurements Proc. 12th Int. Conf. on Biomagnetism (Espoo, Aug. 2000) (Espoo: Helsinki University of Technology) pp 813-20
Cited by
A new wearable multichannel magnetocardiogram system with a SERF atomic magnetometer array
Yang, Y., Xu, M., Liang, A., Yin, Y., Ma, X., Gao, Y., & Ning, X. (2021) · Scientific Reports · doi:10.1038/s41598-021-84971-7 · Cited by 125
“To obtain the cardiac magnetic field distribution on the whole thoracic surface of the subject simultaneously, 20-channel MCG signals at a 4 × 5 region were detected, covering the area of (B, C, D, E) × (2, 3, 4, 5, 6), which is close to the heart.”
MethodMillimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Preprocessing and Denoising Techniques for Electrocardiography and Magnetocardiography: A Review
Jia, Y., Pei, H., Liang, J., Zhou, Y., Yang, Y., Cui, Y., & Xiang, M. (2024) · Bioengineering · doi:10.3390/bioengineering11111109 · Cited by 93
Cardiac Conduction Velocity, Remodeling and Arrhythmogenesis
Han, B., Trew, M. L., & Zgierski-Johnston, C. M. (2021) · Cells · doi:10.3390/cells10112923 · Cited by 69
Magnetocardiography measurements with4He vector optically pumped magnetometers at room temperature
Morales, S., Corsi, M. C., Fourcault, W., Bertrand, F., Cauffet, G., Gobbo, C., Alcouffe, F., Lenouvel, F., Le Prado, M., Berger, F., et al. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa6459 · Cited by 56
Zheng, W., Su, S., Zhang, G., Bi, X., & Lin, Q. (2019) · Biomedical Optics Express · doi:10.1364/boe.380314 · Cited by 49
Cellular and Molecular Effects of Magnetic Fields
Tota, M., Jonderko, L., Witek, J., Novickij, V., & Kulbacka, J. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25168973 · Cited by 52
A Review of Magnetic Field Emissions From the Human Body: Sources, Sensors, and Uses
Zhu, K., & Kiourti, A. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3186643 · Cited by 44
“In addition, devices that capture bio-electric fields rely on electrodes that are in direct contact with the skin or scalp, making the procedure intrusive [4].”
BackgroundAlday, E. A. P., Ni, H., Zhang, C., Colman, M. A., Gan, Z., & Zhang, H. (2016) · PLOS ONE · doi:10.1371/journal.pone.0160999 · Cited by 32
“The MCG and ECG experimental data was obtained from a 25 years old healthy (no cardiac disease presented) subject.”
BackgroundMethodResultInfluentialAI Aided Noise Processing of Spintronic Based IoT Sensor for Magnetocardiography Application
Mohsen, A. S., Al‐Mahdawi, M., Fouda, M. M., Oogane, M., Ando, Y., & Fadlullah, Z. M. (2020) · International Conference on Communications · doi:10.1109/icc40277.2020.9148617 · Cited by 23
“, the cardiac source imaging was identified to be an important research topic in [18] since the spatial properties of MCG and ECG mapping are not well known.”
BackgroundMiniature Coil Array for Passive Magnetocardiography in Non-Shielded Environments
Zhu, K., Shah, A. M., Berkow, J., & Kiourti, A. (2021) · IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology · doi:10.1109/jerm.2020.3019891 · Cited by 22
“contact with the human body, making it an uncomfortable procedure [6].”
BackgroundRoth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Zhang, S. H., Tse, Z. T. H., Dumoulin, C. L., Kwong, R. Y. K., Stevenson, W. G., Watkins, R. D., Ward, J., Wang, W., & Schmidt, E. J. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25810 · Cited by 17
Bedside Magnetocardiography with a Scalar Sensor Array
Iwata, G. Z., Nguyen, C. T., Tharratt, K., Ruf, M., Reinhardt, T., Crivelli-Decker, J. E., Liddy, M. S. Z., Rugar, A. E., Lu, F., Aschbacher, K., et al. (2024) · Sensors · doi:10.3390/s24165402 · Cited by 12
“Numerous studies have demonstrated that MCG can provide complementary information to electro-cardiography (ECG) for more confident identification of ischemic disease using MFMs, which can be parameterized by various features of the magnetic field morphology [8–12].”
BackgroundOptimized Magnetic Field Matrix Modeling and Adjustive Excitation in a Multiplex Compensation System
Zhang, L., Shi, M., Zhang, X., Yang, J., Tian, K., Ma, Y., Shi, Z., & Liu, G. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3527604 · Cited by 12
“The establishment of this environment is critical for ensuring the high-precision operation of spin-exchange relaxation-free (Serf) magnetometers and avoiding environmental interference [4], [5].”
Ultra-sensitive vector magnetometer for magnetocardiographic mapping
Gusev, N. A., Vetoshko, P. M., Kuzmichev, A. N., Chepurnova, D. A., Samoilova, E. V., Zvezdin, A. K., Korotaeva, A. A., & Belotelov, V. I. (2017) · Biomedical Engineering · doi:10.1007/s10527-017-9705-8 · Cited by 9
Wang, Y., Wang, H., Yang, Y., Liu, Z., Pang, J., Cui, P., & Xiang, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.116353 · Cited by 12
Millimetre-scale magnetocardiography of living rats using a solid-state quantum sensorPreprint
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Xin, Z., Nishio, Y., Cao, X., Hatano, Y., Onoda, S., et al. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2105.11676 · Cited by 6
Sampling and Layout of OPM Arrays for MCG Based on the Sampling Theorem
Niu, H., Huang, Z., Pang, M., & Bai, G.-H. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3553186 · Cited by 6
“It can provide current information that is difficult to obtain by traditional ECG [1] and is capable of reflecting pathological abnormality in myocardial contraction.”
Albertová, P., Gram, M., Blaimer, M., Bauer, W. R., Jakob, P. M., & Nordbeck, P. (2024) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30190 · Cited by 6
“However, the probably most valuable application for basic research and clinical diagnostics is non-invasive sensing of cardiac biomagnetism [21].”
Greedy Optimization of Sensor Array Geometry for Magnetocardiographic Source Localization
Veen, B. D. V., Stenroos, M., & Wakai, R. T. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3524374 · Cited by 6
“The array designs are strongly influenced by source location because posterior sources are difficult to localize if the sensors are confined to the front of the torso [22].”
Self-citationMagnetocardiography did not uncover electrically silent ischemia in an in-silico study case
Potyagaylo, D., Seemann, G., Schulze, W. H. W., & Dössel, O. (2015) · Computing in cardiology · doi:10.1109/cic.2015.7411118 · Cited by 5
“In comparison to ECG, MCG was shown to be more sensitive to tangential currents in the heart [4].”
BackgroundZhang, M., Wang, Y., Li, P., Zhang, Y., & Xiang, M. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3604125 · Cited by 2
“23 S / m for torso, lungs, and heart, respectively [42].”
InfluentialMäntynen, V., Lehto, M., Parikka, H. J., & Montonen, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aaa3bb · Cited by 4
Self-citationModelling the Electrical Activity of the Heart
Alonso, S., & dos Santos, R. W. (2019) · Series in bioengineering · doi:10.1007/978-981-10-5092-3_10 · Cited by 2
Mayorca-Torres, D., Salas, A. L., & Peluffo-Ordóñez, D. H. (2025) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03264-z · Cited by 4
Wang, W., Tang, J., Zhao, F., Zhang, L., Zhai, Y., & Zhang, H. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3593510 · Cited by 4
“Therefore, designing UMFCs capable of generating a highly uniform magnetic field under asymmetric magnetic field coupling is essential for suppressing radial environmental magnetic field fluctuations and improving the signal-to-noise ratio (SNR) of MCG measurements [14].”
Yang, M., Sun, C., Zhao, B., Wu, B., Xiang, J., Xu, M., Wu, T., Zhang, J., Xu, W., & Guo, H. M. (2024) · medRxiv · doi:10.1101/2024.01.31.24302044 · Cited by 3
Chen, J., Ye, C., Sun, L., Xiao, Q., Wang, L., & Niu, Y. (2024) · Academic Conference of China Instrument and Control Society (ACCIS) · doi:10.1109/accis62068.2024.10948626 · Cited by 1
Classification of current density vector map using transformer hybrid residual network
Zhu, L., Yang, Y., Yu, W., Zeng, Q., Zheng, Z., Lin, Q., Zhao, X., & Hu, Z. (2025) · PLoS ONE · doi:10.1371/journal.pone.0338189 · Cited by 1
“Moreover, compared to Electrocardiogram (ECG) [9–11].”
Effects of Magnetocardiography Array Errors on Cardiac Source Imaging
Zhang, M., Wang, Y., Li, P., Zhang, Y., Cui, Y., & Xiang, M. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3676206 · Cited by 2
“The direction of each dipole was fixed normal to the local geometry surface [9].”
InfluentialModel-based cardiac field artefact correction for OP-MEG
Woelk, S. P., Alexander, N., O’Neill, G. C., Garfinkel, S. N., & Barnes, G. R. (2026) · Imaging Neuroscience · doi:10.1162/imag.a.1353 · Cited by 1
“In medical magnetocardiog-raphy (MCG), a distributed source model is usually applied to be able to describe the full complexity of the heart’s activity ( M ä ntynen et al., 2014).”
InfluentialEnhancing Current-Source Imaging in Magnetocardiography: The Impact of Sensor Array Configuration
Shang, W., Fushimi, M., Chikaki, S., & Sekino, M. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04343-y · Cited by 1
Impact of filtration elements on bioelectrical signal
Grigoriev, M., & Babich, L. (2016) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/124/1/012060
Recent advances in magnetocardiography
Kong, X., Yang, K., Zhang, Z., Pan, D., & Guo, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00001-2 · Cited by 2
Signal Recovery During the Cardiac Cycle Using Combined Magnetocardiography and Electrocardiography
Wang, Y., Wang, H., Pang, J., Xiang, M., & Cui, P. (2025) · International Conference on Bioinformatics Research and Applications (ICBRA) · doi:10.1145/3774976.3774982
“However, recent cardiac source imaging studies based on dipole source models primarily emphasize spatial accuracy, with less focus on temporal sequence precision [2, 9, 11, 12].”
K-means-based decision-level fusion of ECG and MCG for cardiac source imaging
Wang, Y., Cui, P., & Xiang, M. (2025) · International Conference on Biomedical Imaging, Signal Processing (ICBSP) · doi:10.1117/12.3101395
“4–7 Despite this promising potential, conventional fusion methods often necessitate synchronous signal acquisition or complex processing pipelines, which present considerable technical and clinical challenges that limit their practical application.”
Wang, Y., Zhang, X., Zhang, M., Xiang, M., & Cui, P. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109913
Hernandez-Cardoso, G. G., Plamper, D., Aßmann, C., Honsberg, M., & Sacher, J. (2026) · Vertical-Cavity Surface-Emitting Lasers · doi:10.1117/12.3077455
“Magnetic field sensing is of broad relevance across diverse application areas, including healthcare (e.g., monitoring brain, 1 cardiac, 2 and muscle activity 3 ), navigation systems for attitude determination, 4 and battery technology.”
Magnetocardiographic Simulation and Analysis of Cardiac QT Interval Disorders
Zhang, Y., Cui, Y., Bai, G.-H., Xiang, M., Shang, R., & Pang, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3674249
“CNN o ff ers an optimal trade-o ff between model complexity and classification accuracy, making it well suited for clinical implementation [33], [34].”
Advances and challenges in superconducting/magnetoresistive composite magnetic field sensors
Zhang, S., Ding, Q., Li, G., Li, P., Pan, M., Peng, J., Qiu, W., Hu, J., & Hu, Y. (2026) · Superconductor Science and Technology · doi:10.1088/1361-6668/ae6980
“These factors have constrained the widespread deployment of superconducting magnetic sensors outside the laboratory, especially in scenarios requiring miniaturization, low cost, and dynamic weak-field detection, as exemplified by biological magnetic imaging [3, 4].”
Li, X., Lin, S., Sun, L. P., Yu, Y., Liu, H., & Wang, Z. (2026) · Reviews in Cardiovascular Medicine · doi:10.31083/rcm47473
“MCG can sensitively capture current changes induced by ischemic myocardium, offering superior sensitivity and specificity [11,12].”
Yu, X., Tang, J., Qiu, S., & Zhang, D. (2026) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc66907.2026.11694449
“By exploiting high-sensitivity multi-sensor arrays, MCG offers potential advantages over electrocardiography (ECG) in terms of measurement sensitivity and spatial resolution, thereby improving the reliability of pathological source localisation [3], [4].”
Source Localization Performance of Wearable OPM-MCG System: A CraméR-Rao Bound Analysis
Zhang, M., & Xiang, M. (2026) · Asian Control Conference (ASCC) · doi:10.1109/ascc70886.2026.11701981
Metadata
- Authors
- Mäntynen, V., Konttila, T., & Stenroos, M.
- Affiliations
- Helsinki University Hospital (FI)
- Aalto University (FI)
- Corresponding author
- Mäntynen, Ville
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-11-03
- Volume
- 59
- Issue
- 23
- Pages
- 7141-7158
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2070183748
- Cited by
- 45
- References
- 58
- Citations by year
- 2026: 10 · 2025: 9 · 2024: 9 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 2 · 2017: 3 · 2016: 2 · 2015: 2
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
- creativecommons.org/licenses/by/3.0/ (vor)
- Locations
- Physics in Medicine and Biology (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
- Keywords
- electrocardiogram, magnetocardiography, inverse problems, sensitivity distribution, point spread function, thorax model, volume conductor model, distributed source model, source orientation
- MeSH terms
- Electrocardiography, Heart, Humans, Models, Cardiovascular, Sensitivity and Specificity, Thorax, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.