Advances in kilovoltage x-ray beam dosimetry
Open accessThe DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
This topical review provides an up-to-date overview of the theoretical and practical aspects of therapeutic kilovoltage x-ray beam dosimetry. Kilovoltage x-ray beams have the property that the maximum dose occurs very close to the surface and thus, they are predominantly used in the treatment of skin cancers but also have applications for the treatment of other cancers. In addition, kilovoltage x-ray beams are used in intra operative units, within animal irradiators and in on-board imagers on linear accelerators and kilovoltage dosimetry is important in these applications as well. This review covers both reference and relative dosimetry of kilovoltage x-ray beams and provides recommendations for clinical measurements based on the literature to date. In particular, practical aspects for the selection of dosimeter and phantom material are reviewed to provide suitable advice for medical physicists. An overview is also presented of dosimeters other than ionization chambers which can be used for both relative and in vivo dosimetry. Finally, issues related to the treatment planning and the use of Monte Carlo codes for solving radiation transport problems in kilovoltage x-ray beams are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106 · cited 3×
“The Monte Carlo codes applicable for medical radiation physics are EGSnrc (Kawrakow 2000a, 2000b), FLUKA (Kling et al 2001), GEANT4 (Agostinelli et al 2003, Allison et al 2006), MCNPX (Kling et al 2001, Verhaegen and Seuntjens 2003, Waters et al 2007) and PENELOPE (Salvat et al 2006a, Sempau et al 2003).”
MethodGeant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
Principles and Practice of Radiation Oncology
Perez, C., & Brady, L. (1999) · Journal of Pediatric Hematology/Oncology · doi:10.1097/00043426-199911000-00025 · Cited by 1,871
Introduction to Radiological Physics and Radiation Dosimetry
Attix, F. H. (1986) · Wiley eBooks · doi:10.1002/9783527617135 · Cited by 1,868
Relative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
PENELOPE: A code system for Monte Carlo simulation of electron and photon transport
(2020) · Penelope · doi:10.1787/9d2cc3d5-en · Cited by 1,275
Tissue Substitutes in Radiation Dosimetry and Measurement
Cloutier, R. J. (1989) · Radiation Research · doi:10.2307/3577533 · Cited by 1,076
Kawrakow, I. (2000) · Medical Physics · doi:10.1118/1.598917 · Cited by 945 · cited 10×
“Ali and Rogers (2008a) performed a range of benchmark calculations of the EGSnrc code in the kilovoltage energy range for charged particle backscatter coefficients R215 with comparison against experimental measurements.”
MethodInfluentialBaldock, C., De Deene, Y., Doran, S., Ibbott, G., Jirasek, A., Lepage, M., McAuley, K. B., Oldham, M., & Schreiner, L. J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/r01 · Cited by 881 · cited 4×
“…3D dosimeters which include being insensitive to oxygen, having a solid form which means it can be designed to the required shape and that it is light absorbing rather than scattering which allows readout by optical CT scanner (Adamovics and Maryanski 2006, Baldock et al 2010, Guo et al 2006).”
BackgroundInfluentialSelf-citationAAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiology
Ma, C. ‐., Coffey, C. W., DeWerd, L. A., Liu, C., Nath, R., Seltzer, S. M., & Seuntjens, J. P. (2001) · Medical Physics · doi:10.1118/1.1374247 · Cited by 816
Cited by
Scintillating Nanoparticles as Energy Mediators for Enhanced Photodynamic Therapy
Kamkaew, A., Chen, F., Zhan, Y., Majewski, R. L., & Cai, W. (2016) · ACS Nano · doi:10.1021/acsnano.6b01401 · Cited by 355
Deng, J., Xu, S., Hu, W., Xun, X., Zheng, L., & Su, M. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.048 · Cited by 234
Wireless on-demand drug delivery
Mirvakili, S. M., & Langer, R. (2021) · Nature Electronics · doi:10.1038/s41928-021-00614-9 · Cited by 202
Metadata
- Authors
- Hill, R., Healy, B., Holloway, L., Kuncic, Z., Thwaites, D., & Baldock, C.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-02-28
- Volume
- 59
- Issue
- 6
- Pages
- R183-R231
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2093999430
- Cited by
- 176
- References
- 81
- FWCI
- 17.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.