Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Cavitation events seeded by microbubbles have been previously reported to be associated with MR- or fluorescent-contrast enhancement after focused ultrasound (FUS)-induced blood-brain barrier (BBB) opening. However, it is still unknown whether bubble activity can be correlated with the reversibility (the duration of opening and the likelihood of safe reinstatement) and the permeability of opened BBB, which is critical for the clinical translation of using passive cavitation detection to monitor, predict and control the opening. In this study, the dependence of acoustic cavitation on the BBB opening duration, permeability coefficient and histological damage occurrence were thus investigated. Transcranial pulsed FUS at 1.5 MHz in the presence of systemically circulating microbubbles was applied in the mouse hippocampi (n = 60). The stable and inertial cavitation activities were monitored during sonication. Contrast-enhanced MRI was performed immediately after sonication and every 24 h up to 6 d thereafter, to assess BBB opening, brain tissue permeability and potential edema. Histological evaluations were used to assess the occurrence of neurovascular damages. It was found that stable cavitation was well correlated with: (1) the duration of the BBB opening (r(2) = 0.77); (2) the permeability of the opened BBB (r(2) = 0.82); (3) the likelihood of safe opening (P < 0.05, safe opening compared to cases of damage; P < 0.0001, no opening compared to safe opening). The inertial cavitation dose was correlated with the resulting BBB permeability (r(2) = 0.72). Stable cavitation was found to be more reliable than inertial cavitation at assessing the BBB opening within the pressure range used in this study. This study demonstrates that the stable cavitation response during BBB opening holds promise for predicting and controlling the restoration and pharmacokinetics of FUS-opened BBB. The stable cavitation response therefore showed great promise in predicting the BBB opening duration, enabling thus control of opening according to the drug circulation time. In addition, avoiding adverse effects in the brain and assessing the pharmacokinetics of the compounds delivered can also be achieved by monitoring and controlling the stable cavitation emissions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The blood-brain barrier: Bottleneck in brain drug development
Pardridge, W. M. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.3 · Cited by 2,798 · cited 2×
“BBB prevents permeation of molecules greater than 400 Da from the vasculature to the brain parenchyma, rendering many potent drugs ineffective (Pardridge 2005).”
InfluentialHsu, P.-H., Wei, K.-C., Huang, C.-Y., Wen, C.-J., Yen, T.-C., Liu, C.-L., Lin, Y.-T., Chen, J.-C., Shen, C.-R., & Liu, H.-L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057682 · Cited by 136 · cited 1×
“The threshold of inertial cavitation predicted by the Mechanical Index (MI, fPRP / c), which is the standard indicator for adverse bio-effects, is MI = 0.4 (Holland et al 2000, Bader and Holland 2013).”
InfluentialTung, Y.-S., Marquet, F., Teichert, T., Ferrera, V., & Konofagou, E. E. (2011) · Applied Physics Letters · doi:10.1063/1.3580763 · Cited by 119 · cited 12×
“Contrastenhanced MRI has been employed to detect the opening (Hynynen and McDannold 2001, Tung et al 2011a, McDannold et al 2012), assess any potential damage (Tung et al 2011b, McDannold et al 2012), map the permeability (Vlachos et al 2010, Park et al 2012) and monitor BBB closing (Samiotaki et…”
BackgroundMethodResultSelf-citationFan, C.-H., Liu, H.-L., Ting, C.-Y., Lee, Y.-H., Huang, C.-Y., Ma, Y.-J., Wei, K.-C., Yen, T.-C., & Yeh, C.-K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096327 · Cited by 84
Cited by
Mechanical and Biological Effects of Ultrasound: A Review of Present Knowledge
Izadifar, Z., Babyn, P., & Chapman, D. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.01.023 · Cited by 280
Sun, T., Zhang, Y., Power, C., Alexander, P. M., Sutton, J. T., Aryal, M., Vykhodtseva, N., Miller, E. L., & McDannold, N. J. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1713328114 · Cited by 258
Self-citationWang, J., Li, Z., Pan, M., Fiaz, M., Hao, Y., Yan, Y., Sun, L., & Yan, F. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114539 · Cited by 161
Bae, S., Liu, K., Pouliopoulos, A. N., Ji, R., Jiménez-Gambín, S., Yousefian, O., Kline-Schoder, A. R., Batts, A. J., Tsitsos, F. N., Kokossis, D., et al. (2024) · Theranostics · doi:10.7150/thno.94206 · Cited by 70
“Due to these effects, monitoring of broadband CDs has been utilized to prevent tissue damage in mice [52,53] and non-human primates [33].”
Self-citationTanaka, M., Araujo, A. C., Valenti, V. E., Guiguer, E. L., Catharin, V. C. S., Gualhardi, C. M., de Souza Bastos Mazuqueli Pereira, E., de Alvares Goulart, R., de Argolo Haber, R. S., de Carvalho, A. C. A., et al. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27052370 · Cited by 13
Metadata
- Authors
- Sun, T., Samiotaki, G., Wang, S., Acosta, C., Chen, C. C., & Konofagou, E. E.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-11-12
- Volume
- 60
- Issue
- 23
- Pages
- 9079-9094
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2265706680
- Cited by
- 133
- References
- 4
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening. https://app.cochat.ai/papers/10.1088/0031-9155/60/23/9079
- The paper
- Sun, T., Samiotaki, G., Wang, S., Acosta, C., Chen, C. C., & Konofagou, E. E. (2015). Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening. Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/60/23/9079
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.