Optical coherence tomography - principles and applications
Open accessThe DOI matches its Crossref record; 105 of the 105 references it cites were found in a registry or an index.
Abstract
There have been three basic approaches to optical tomography since the early 1980s: diffraction tomography, diffuse optical tomography and optical coherence tomography (OCT). Optical techniques are of particular importance in the medical field, because these techniques promise to be safe and cheap and, in addition, offer a therapeutic potential. Advances in OCT technology have made it possible to apply OCT in a wide variety of applications but medical applications are still dominating. Specific advantages of OCT are its high depth and transversal resolution, the fact, that its depth resolution is decoupled from transverse resolution, high probing depth in scattering media, contact-free and non-invasive operation, and the possibility to create various function dependent image contrasting methods. This report presents the principles of OCT and the state of important OCT applications. OCT synthesises cross-sectional images from a series of laterally adjacent depth-scans. At present OCT is used in three different fields of optical imaging, in macroscopic imaging of structures which can be seen by the naked eye or using weak magnifications, in microscopic imaging using magnifications up to the classical limit of microscopic resolution and in endoscopic imaging, using low and medium magnification. First, OCT techniques, like the reflectometry technique and the dual beam technique were based on time-domain low coherence interferometry depth-scans. Later, Fourier-domain techniques have been developed and led to new imaging schemes. Recently developed parallel OCT schemes eliminate the need for lateral scanning and, therefore, dramatically increase the imaging rate. These schemes use CCD cameras and CMOS detector arrays as photodetectors. Video-rate three-dimensional OCT pictures have been obtained. Modifying interference microscopy techniques has led to high-resolution optical coherence microscopy that achieved sub-micrometre resolution. This report is concluded with a short presentation of important OCT applications. Ophthalmology is, due to the transparent ocular structures, still the main field of OCT application. The first commercial instrument too has been introduced for ophthalmic diagnostics (Carl Zeiss Meditec AG). Advances in using near-infrared light, however, opened the path for OCT imaging in strongly scattering tissues. Today, optical in vivo biopsy is one of the most challenging fields of OCT application. High resolution, high penetration depth, and its potential for functional imaging attribute to OCT an optical biopsy quality, which can be used to assess tissue and cell function and morphology in situ . OCT can already clarify the relevant architectural tissue morphology. For many diseases, however, including cancer in its early stages, higher resolution is necessary. New broad-bandwidth light sources, like photonic crystal fibres and superfluorescent fibre sources, and new contrasting techniques, give access to new sample properties and unmatched sensitivity and resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Goodman, J. W. (1985) · Cited by 4,004
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Durnin, J., Miceli, J. J., & Eberly, J. H. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.1499 · Cited by 3,667
Ranka, J. K., Windeler, R. S., & Stentz, A. J. (2000) · Optics Letters · doi:10.1364/ol.25.000025 · Cited by 2,179
Some fundamental properties of speckle*
Goodman, J. W. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.001145 · Cited by 2,125
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Laser Speckle and Related Phenomena
(1975) · Topics in Applied Physics · doi:10.1007/978-3-662-43205-1 · Cited by 1,330
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Self-citationOptical Coherence Tomography: An Emerging Technology for Biomedical Imaging and Optical Biopsy
Fujimoto, J. G., Pitris, C., Boppart, S. A., & Brezinski, M. E. (2000) · Neoplasia · doi:10.1038/sj.neo.7900071 · Cited by 1,138
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962 · cited 1×
“Such a laser has been used in some of the most advanced OCT techniques like spectroscopic OCT (Morgner et al 2000) and ultra-high-resolution OCT (Drexler et al 1999, 2001).”
MethodSelf-citationIn vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Self-citationIn vivo retinal imaging by optical coherence tomography
Swanson, E. A., Izatt, J. A., Lin, C. P., Fujimoto, J. G., Schuman, J. S., Hee, M. R., Huang, D., & Puliafito, C. A. (1993) · Optics Letters · doi:10.1364/ol.18.001864 · Cited by 918
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
Self-citationOptical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
de Boer, J. F., Milner, T. E., van Gemert, M. J. C., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000934 · Cited by 883
Hartl, I., Li, X. D., Chudoba, C., Ghanta, R. K., Ko, T. H., Fujimoto, J. G., Ranka, J. K., & Windeler, R. S. (2001) · Optics Letters · doi:10.1364/ol.26.000608 · Cited by 852
Speckle in Optical Coherence Tomography
Schmitt, J. M., Xiang, S. H., & Yung, K. M. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429925 · Cited by 837
Supercontinuum generation in tapered fibers
Birks, T. A., Wadsworth, W. J., & Russell, P. S. J. (2000) · Optics Letters · doi:10.1364/ol.25.001415 · Cited by 810
LOCALIZED FLUID FLOW MEASUREMENTS WITH AN He–Ne LASER SPECTROMETER
Yeh, Y., & Cummins, H. Z. (1964) · Applied Physics Letters · doi:10.1063/1.1753925 · Cited by 767
Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging
Briers, J. D. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/4/201 · Cited by 686
High-resolution femtosecond pulse shaping
Weiner, A. M., Heritage, J. P., & Kirschner, E. M. (1988) · Journal of the Optical Society of America B · doi:10.1364/josab.5.001563 · Cited by 672
Optical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
Photophysical processes in recent medical laser developments: A review
Boulnois, J.-L. (1986) · Lasers in Medical Science · doi:10.1007/bf02030737 · Cited by 661
Optical coherence tomography in dermatology: a review
Welzel, J. (2001) · Skin Research and Technology · doi:10.1034/j.1600-0846.2001.007001001.x · Cited by 621
OCT elastography: imaging microscopic deformation and strain of tissue
Schmitt, J. M. (1998) · Optics Express · doi:10.1364/oe.3.000199 · Cited by 620
Izatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J. (1997) · Optics Letters · doi:10.1364/ol.22.001439 · Cited by 609
Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging
Hee, M. R., Swanson, E. A., Fujimoto, J. G., & Huang, D. (1992) · Journal of the Optical Society of America B · doi:10.1364/josab.9.000903 · Cited by 582
Handbook of Optical Coherence Tomography
(2001) · CRC Press eBooks · doi:10.1201/b14024 · Cited by 580
High-resolution full-field optical coherence tomography with a Linnik microscope
Dubois, A., Vabre, L., Boccara, A.-C., & Beaurepaire, E. (2002) · Applied Optics · doi:10.1364/ao.41.000805 · Cited by 567
Optical Coherence Tomography for Optical Biopsy: Properties and Demonstration of Vascular Pathology
Brezinski, M. E., Tearney, G. J., Bouma, B. E., Izatt, J. A., Hee, M. R., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1996) · Circulation · doi:10.1161/01.cir.93.6.1206 · Cited by 566
Zhao, Y., Chen, Z., Saxer, C., Xiang, S., de Boer, J. F., & Nelson, J. S. (2000) · Optics Letters · doi:10.1364/ol.25.000114 · Cited by 559
Spectroscopic optical coherence tomography
Morgner, U., Drexler, W., Kärtner, F. X., Li, X. D., Pitris, C., Ippen, E. P., & Fujimoto, J. G. (2000) · Optics Letters · doi:10.1364/ol.25.000111 · Cited by 516
Self-citationSub-two-cycle pulses from a Kerr-lens mode-locked Ti:sapphire laser
Morgner, U., Kärtner, F. X., Cho, S. H., Chen, Y., Haus, H. A., Fujimoto, J. G., Ippen, E. P., Scheuer, V., Angelow, G., & Tschudi, T. (1999) · Optics Letters · doi:10.1364/ol.24.000411 · Cited by 483
Submicrometer axial resolution optical coherence tomography
Povazay, B., Bizheva, K., Unterhuber, A., Hermann, B., Sattmann, H., Fercher, A. F., Drexler, W., Apolonski, A., Wadsworth, W. J., Knight, J. C., et al. (2002) · Optics Letters · doi:10.1364/ol.27.001800 · Cited by 480
Self-citationIn Vivo Optical Coherence Tomography
Fercher, A. F., Hitzenberger, C. K., Drexler, W., Kamp, G., & Sattmann, H. (1993) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)71762-3 · Cited by 467
Self-citationHigh-speed phase- and group-delay scanning with a grating-based phase control delay line
Tearney, G. J., Bouma, B. E., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.001811 · Cited by 449
Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
Chen, Z., Milner, T. E., Dave, D., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000064 · Cited by 443
Review of polarization sensitive optical coherence tomography and Stokes vector determination
de Boer, J. F., & Milner, T. E. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483879 · Cited by 440
Full-field optical coherence microscopy
Beaurepaire, E., Boccara, A. C., Lebec, M., Blanchot, L., & Saint-Jalmes, H. (1998) · Optics Letters · doi:10.1364/ol.23.000244 · Cited by 433
Optical reflectance and transmittance of tissues: principles and applications
Wilson, B. C., & Jacques, S. L. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64355 · Cited by 421
In vivo video rate optical coherence tomography
Rollins, A. M., Kulkarni, M. D., Yazdanfar, S., Ung-arunyawee, R., & Izatt, J. A. (1998) · Optics Express · doi:10.1364/oe.3.000219 · Cited by 414
Optical scattering properties of soft tissue: a discrete particle model
Schmitt, J. M., & Kumar, G. (1998) · Applied Optics · doi:10.1364/ao.37.002788 · Cited by 408
Hitzenberger, C., Goetzinger, E., Sticker, M., Pircher, M., & Fercher, A. (2001) · Optics Express · doi:10.1364/oe.9.000780 · Cited by 391
Self-citationLaser Doppler measurements of blood flow in capillary tubes and retinal arteries.
Riva, C. E., Ross, B., & Benedek, G. B. (1972) · PubMed · Cited by 362
Optical coherence tomography and microscopy in gastrointestinal tissues
Izatt, J. A., Kulkarni, M. D., Wang, H.-W., Kobayashi, K., & Sivak, M. V. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.577331 · Cited by 350
Zangwill, L. M. (2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.7.985 · Cited by 344
Turbulent nature of refractive-index variations in biological tissue
Schmitt, J. M., & Kumar, G. (1996) · Optics Letters · doi:10.1364/ol.21.001310 · Cited by 343
Di Rienzo, S. (1950) · PubMed · Cited by 340
Fried, D., Xie, J., Shafi, S., Featherstone, J. D. B., Breunig, T. M., & Le, C. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1509752 · Cited by 331
High-speed fiber–based polarization-sensitive optical coherence tomography of in vivo human skin
Saxer, C. E., de Boer, J. F., Park, B. H., Zhao, Y., Chen, Z., & Nelson, J. S. (2000) · Optics Letters · doi:10.1364/ol.25.001355 · Cited by 302
Use of an agent to reduce scattering in skin
Vargas, G., Chan, E. K., Barton, J. K., Rylander, H. G., & Welch, A. J. (1999) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1999)24:2<133::aid-lsm9>3.0.co;2-x · Cited by 302
Depolarization of light backscattered by randomly oriented nonspherical particles
Mishchenko, M. I., & Hovenier, J. W. (1995) · Optics Letters · doi:10.1364/ol.20.001356 · Cited by 297
White-light supercontinuum generation with 60-ps pump pulses in a photonic crystal fiber
Coen, S., Chau, A. H. L., Leonhardt, R., Harvey, J. D., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2001) · Optics Letters · doi:10.1364/ol.26.001356 · Cited by 279
High resolution in vivo intra-arterial imaging with optical coherence tomography
Fujimoto, J. G., Boppart, S. A., Tearney, G. J., Bouma, B. E., Pitris, C., & Brezinski, M. E. (1999) · Heart · doi:10.1136/hrt.82.2.128 · Cited by 276
Quantum-optical coherence tomography with dispersion cancellation
Abouraddy, A. F., Nasr, M. B., Saleh, B. E. A., Sergienko, A. V., & Teich, M. C. (2002) · Physical Review A · doi:10.1103/physreva.65.053817 · Cited by 270
Birefringence characterization of biological tissue by use of optical coherence tomography
Everett, M. J., Schoenenberger, K., Colston, B. W., & Da Silva, L. B. (1998) · Optics Letters · doi:10.1364/ol.23.000228 · Cited by 269
Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography
Leitgeb, R., Wojtkowski, M., Kowalczyk, A., Hitzenberger, C. K., Sticker, M., & Fercher, A. F. (2000) · Optics Letters · doi:10.1364/ol.25.000820 · Cited by 267
Self-citationde Boer, J. F., Milner, T. E., & Nelson, J. S. (1999) · Optics Letters · doi:10.1364/ol.24.000300 · Cited by 261
Analysis of optical coherence tomography systems based on the extended Huygens–Fresnel principle
Thrane, L., Yura, H. T., & Andersen, P. E. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000484 · Cited by 247
Brezinski, M. E., Tearney, G. J., Weissman, N. J., Boppart, S. A., Bouma, B. E., Hee, M. R., Weyman, A. E., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1997) · Heart · doi:10.1136/hrt.77.5.397 · Cited by 241
Polarization–Sensitive Optical Coherence Tomography of Dental Structures
Baumgartner, A., Dichtl, S., Hitzenberger, C. K., Sattmann, H., Robl, B., Moritz, A., Fercher, A. F., & Sperr, W. (2000) · Caries Research · doi:10.1159/000016571 · Cited by 235
Self-citationYao, G., & Wang, L. V. (1999) · Optics Letters · doi:10.1364/ol.24.000537 · Cited by 232
Semiconductor lasers for coherent optical fiber communications
Koch, T. L., & Koren, U. (1990) · Journal of Lightwave Technology · doi:10.1109/50.50725 · Cited by 230
Dreher, A. W., Reiter, K., & Weinreb, R. N. (1992) · Applied Optics · doi:10.1364/ao.31.003730 · Cited by 217
Imaging thermally damaged tissue by Polarization Sensitive Optical Coherence Tomography
De Boer, J., Srinivas, S., Malekafzali, A., Chen, Z., & Nelson, J. (1998) · Optics Express · doi:10.1364/oe.3.000212 · Cited by 211
Noninvasive monitoring of glucose concentration with optical coherence tomography
Esenaliev, R. O., Larin, K. V., Larina, I. V., & Motamedi, M. (2001) · Optics Letters · doi:10.1364/ol.26.000992 · Cited by 204
IV Advanced Evaluation Techniques in Interferometry
Schwider, J. (1990) · Progress in Optics · doi:10.1016/s0079-6638(08)70291-9 · Cited by 199
Colston, B. W., Sathyam, U. S., DaSilva, L. B., Everett, M. J., Stroeve, P., & Otis, L. L. (1998) · Optics Express · doi:10.1364/oe.3.000230 · Cited by 197
Refraction of diffuse photon density waves
O’Leary, M. A., Boas, D. A., Chance, B., & Yodh, A. G. (1992) · Physical Review Letters · doi:10.1103/physrevlett.69.2658 · Cited by 187
In vivo optical coherence tomography imaging of human skin: norm and pathology
Gladkova, N. D., Petrova, G. A., Nikulin, N. K., Radenska‐Lopovok, S. G., Snopova, L. B., Chumakov, Y. P., Nasonova, V. A., Gelikonov, V. M., Gelikonov, G. V., Kuranov, R. V., et al. (2000) · Skin Research and Technology · doi:10.1034/j.1600-0846.2000.006001006.x · Cited by 185
Wavelength-tuning interferometry of intraocular distances
Lexer, F., Hitzenberger, C. K., Fercher, A. F., & Kulhavy, M. (1997) · Applied Optics · doi:10.1364/ao.36.006548 · Cited by 182
Self-citationRollins, A. M., Ung-arunyawee, R., Chak, A., Wong, R. C. K., Kobayashi, K., Sivak, M. V., & Izatt, J. A. (1999) · Optics Letters · doi:10.1364/ol.24.001358 · Cited by 181
Boppart, S. A., Tearney, G. J., Bouma, B. E., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.9.4256 · Cited by 174
Tuchin, V. V., Xu, X., & Wang, R. K. (2002) · Applied Optics · doi:10.1364/ao.41.000258 · Cited by 163
Jiao, S., & Wang, L. V. (2002) · Optics Letters · doi:10.1364/ol.27.000101 · Cited by 163
Image reconstruction in optical tomography
Arridge, S. R., & Schweiger, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0054 · Cited by 160
Frequency domain optical reflectometer
MacDonald, R. I. (1981) · Applied Optics · doi:10.1364/ao.20.001840 · Cited by 160
Ophthalmic Laser Interferometry
Fercher, A. F., & Roth, E. (1986) · SPIE Proceedings · doi:10.1117/12.938523 · Cited by 159
Self-citationApplication of polarization effects in light scattering: a new biophysical tool.
Bickel, W. S., Davidson, J. F., Huffman, D. R., & Kilkson, R. (1976) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.73.2.486 · Cited by 158
Low-coherence optical tomography in turbid tissue: theoretical analysis
Pan, Y., Birngruber, R., Rosperich, J., & Engelhardt, R. (1995) · Applied Optics · doi:10.1364/ao.34.006564 · Cited by 149
Bizheva, K. K., Siegel, A. M., & Boas, D. A. (1998) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.58.7664 · Cited by 144
Polarized light microscopy as a tool of diagnostic pathology.
Wolman, M. (1975) · Journal of Histochemistry & Cytochemistry · doi:10.1177/23.1.1090645 · Cited by 127
Cross-polarized backscatter in optical coherence tomography of biological tissue
Schmitt, J. M., & Xiang, S. (1998) · Optics Letters · doi:10.1364/ol.23.001060 · Cited by 126
Use of optical coherence tomography for assessment of dental caries: quantitative procedure
Amaechi, B. T., Higham, S. M., Podoleanu, A. G., Rogers, J. A., & Jackson, D. A. (2001) · Journal of Oral Rehabilitation · doi:10.1046/j.1365-2842.2001.00840.x · Cited by 124
Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479235 · Cited by 118
Modelling optical properties of soft tissue by fractal distribution of scatterers
Wang, R. K. (2000) · Journal of Modern Optics · doi:10.1080/09500340008231409 · Cited by 118
Dispersion effects in partial coherence interferometry: implications for intraocular ranging
Hitzenberger, C. K. F., Baumgartner, A., Drexler, W., & FERCHER, A. F. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429900 · Cited by 116
Self-citationRen, H., Brecke, K. M., Ding, Z., Zhao, Y., Nelson, J. S., & Chen, Z. (2002) · Optics Letters · doi:10.1364/ol.27.000409 · Cited by 110
Diffraction tomography for biochemical imaging with diffuse-photon density waves
Li, X. D., Durduran, T., Yodh, A. G., Chance, B., & Pattanayak, D. N. (1997) · Optics Letters · doi:10.1364/ol.22.000573 · Cited by 93
New Technology for High‐Speed and High‐Resolution Optical Coherence Tomographya
Fujimoto, J. G., Bouma, B. E., Tearney, G. J., Boppart, S. A., Pitris, C., Southern, J. F., & Brezinski, M. E. (1998) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1998.tb08190.x · Cited by 89
Spectral shaping of supercontinuum in a cobweb photonic-crystal fiber with sub-20-fs pulses
Apolonski, A. A., Považay, B., Unterhuber, A., Drexler, W., Wadsworth, W. J., Knight, J. C., & Russell, P. S. J. (2002) · Journal of the Optical Society of America B · doi:10.1364/josab.19.002165 · Cited by 85
Self-citationWax, A. P., Yang, C., Dasari, R. R., & Feld, M. S. (2001) · Applied Optics · doi:10.1364/ao.40.004222 · Cited by 80
Edelstein, D. C., Romney, R. B., & Scheuermann, M. R. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142109 · Cited by 76
Stable carrier generation and phase-resolved digital data processing in optical coherence tomography
de Boer, J. F., Saxer, C. E., & Nelson, J. S. (2001) · Applied Optics · doi:10.1364/ao.40.005787 · Cited by 72
Detection of tumorigenesis in rat bladders with optical coherence tomography
Pan, Y., Lavelle, J. P., Bastacky, S., Meyers, S., Pirtskhalaishvili, G., Zeidel, M. L., & Farkas, D. L. (2001) · Medical Physics · doi:10.1118/1.1418726 · Cited by 60
Clinical Imaging with Optical Coherence Tomography
Bouma, B. E., & Tearney, G. J. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80465-8 · Cited by 60
Feng, W., Haishu, D., Fenghua, T., Jun, Z., Qing, X., & Xianwu, T. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/1/323 · Cited by 53
Scaling relationships for anisotropic random walks
Gandjbakhche, A., Bonner, R. F., & Nossal, R. (1992) · Journal of Statistical Physics · doi:10.1007/bf01053781 · Cited by 52
Topography and volume measurements of the optic nerve using en-face optical coherence tomography
Rogers, J. A., Podoleanu, A. G., Dobre, G. M., Jackson, D. A., & Fitzke, F. W. (2001) · Optics Express · doi:10.1364/oe.9.000533 · Cited by 37
Spectral interferometric optical coherence tomography with nonlinear β-barium borate time gating
Yasuno, Y., Sutoh, Y., Nakama, M., Makita, S., Itoh, M., Yatagai, T., & Mori, M. (2002) · Optics Letters · doi:10.1364/ol.27.000403 · Cited by 13
Optical Coherence Tomography: A New Technology for Biomedical Imaging
Fujimoto, J. G., Boppart, S. A., Pitris, C., & Brezinski, M. E. (1999) · Nippon Laser Igakkaishi · doi:10.2530/jslsm1980.20.2_141 · Cited by 3
Cited by
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Light-driven micro/nanomotors: from fundamentals to applications
Xu, L., Mou, F., Gong, H., Luo, M., & Guan, J. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00516d · Cited by 628
Metadata
- Authors
- Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2003-01-20
- Volume
- 66
- Issue
- 2
- Pages
- 239-303
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2078920062
- Cited by
- 1,866
- References
- 105
- FWCI
- 39.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.