Optical coherence tomography - principles and applications
Open accessThe DOI matches its Crossref record; 105 of the 105 references it cites were found in a registry or an index.
Abstract
There have been three basic approaches to optical tomography since the early 1980s: diffraction tomography, diffuse optical tomography and optical coherence tomography (OCT). Optical techniques are of particular importance in the medical field, because these techniques promise to be safe and cheap and, in addition, offer a therapeutic potential. Advances in OCT technology have made it possible to apply OCT in a wide variety of applications but medical applications are still dominating. Specific advantages of OCT are its high depth and transversal resolution, the fact, that its depth resolution is decoupled from transverse resolution, high probing depth in scattering media, contact-free and non-invasive operation, and the possibility to create various function dependent image contrasting methods. This report presents the principles of OCT and the state of important OCT applications. OCT synthesises cross-sectional images from a series of laterally adjacent depth-scans. At present OCT is used in three different fields of optical imaging, in macroscopic imaging of structures which can be seen by the naked eye or using weak magnifications, in microscopic imaging using magnifications up to the classical limit of microscopic resolution and in endoscopic imaging, using low and medium magnification. First, OCT techniques, like the reflectometry technique and the dual beam technique were based on time-domain low coherence interferometry depth-scans. Later, Fourier-domain techniques have been developed and led to new imaging schemes. Recently developed parallel OCT schemes eliminate the need for lateral scanning and, therefore, dramatically increase the imaging rate. These schemes use CCD cameras and CMOS detector arrays as photodetectors. Video-rate three-dimensional OCT pictures have been obtained. Modifying interference microscopy techniques has led to high-resolution optical coherence microscopy that achieved sub-micrometre resolution. This report is concluded with a short presentation of important OCT applications. Ophthalmology is, due to the transparent ocular structures, still the main field of OCT application. The first commercial instrument too has been introduced for ophthalmic diagnostics (Carl Zeiss Meditec AG). Advances in using near-infrared light, however, opened the path for OCT imaging in strongly scattering tissues. Today, optical in vivo biopsy is one of the most challenging fields of OCT application. High resolution, high penetration depth, and its potential for functional imaging attribute to OCT an optical biopsy quality, which can be used to assess tissue and cell function and morphology in situ . OCT can already clarify the relevant architectural tissue morphology. For many diseases, however, including cancer in its early stages, higher resolution is necessary. New broad-bandwidth light sources, like photonic crystal fibres and superfluorescent fibre sources, and new contrasting techniques, give access to new sample properties and unmatched sensitivity and resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Optical Coherence and Quantum Optics
Mandel, L., & Wolf, E. (1995) · doi:10.1017/cbo9781139644105 · Cited by 8,356
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
The Fourier Transform and Its Applications
Bracewell, R., & Kahn, P. B. (1966) · American Journal of Physics · doi:10.1119/1.1973431 · Cited by 5,737
Goodman, J. W. (1985) · Cited by 4,004
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Durnin, J., Miceli, J. J., & Eberly, J. H. (1987) · Physical Review Letters · doi:10.1103/physrevlett.58.1499 · Cited by 3,667
Ranka, J. K., Windeler, R. S., & Stentz, A. J. (2000) · Optics Letters · doi:10.1364/ol.25.000025 · Cited by 2,179
Some fundamental properties of speckle*
Goodman, J. W. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.001145 · Cited by 2,125
In Vivo Endoscopic Optical Biopsy with Optical Coherence Tomography
Tearney, G. J., Brezinski, M. E., Bouma, B. E., Boppart, S. A., Pitris, C., Southern, J. F., & Fujimoto, J. G. (1997) · Science · doi:10.1126/science.276.5321.2037 · Cited by 1,364
Cited by
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Light-driven micro/nanomotors: from fundamentals to applications
Xu, L., Mou, F., Gong, H., Luo, M., & Guan, J. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00516d · Cited by 628
Three dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Inorganic nanoparticles for cancer imaging and therapy
Huang, H.-C., Barua, S., Sharma, G., Dey, S. K., & Rege, K. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.06.004 · Cited by 618
Quantum metrology and its application in biology
Taylor, M. A., & Bowen, W. P. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.002 · Cited by 470
Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography
Cense, B., Nassif, N. A., Chen, T. C., Pierce, M. C., Yun, S.-H., Park, B. H., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Express · doi:10.1364/opex.12.002435 · Cited by 468
NIR Spectroscopy Applications for Internal and External Quality Analysis of Citrus Fruit—A Review
Magwaza, L. S., Opara, U. L., Nieuwoudt, H., Cronje, P. J. R., Saeys, W., & Nicolaï, B. (2012) · Food and Bioprocess Technology · doi:10.1007/s11947-011-0697-1 · Cited by 465
Fiber-Optic Sensing: A Historical Perspective
Culshaw, B., & Kersey, A. (2008) · Journal of Lightwave Technology · doi:10.1109/jlt.0082.921915 · Cited by 457
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Wang, R. K., An, L., Francis, P., & Wilson, D. J. (2010) · Optics Letters · doi:10.1364/ol.35.001467 · Cited by 355
PODOLEANU, A. G. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03619.x · Cited by 348
Spectral-domain phase microscopy
Choma, M. A., Ellerbee, A. K., Yang, C., Creazzo, T. L., & Izatt, J. A. (2005) · Optics Letters · doi:10.1364/ol.30.001162 · Cited by 342
Aqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
Underwater Optical Imaging: The Past, the Present, and the Prospects
Jaffe, J. S. (2015) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2014.2350751 · Cited by 312
From a quantum-electrodynamical light–matter description to novel spectroscopies
Ruggenthaler, M., Tancogne-Dejean, N., Flick, J., Appel, H., & Rubio, A. (2018) · Nature Reviews Chemistry · doi:10.1038/s41570-018-0118 · Cited by 307
Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography
Götzinger, E., Pircher, M., Geitzenauer, W., Ahlers, C., Baumann, B., Michels, S., Schmidt-Erfurth, U., & Hitzenberger, C. K. (2008) · Optics Express · doi:10.1364/oe.16.016410 · Cited by 294
Self-citationAn, L., Qin, J., & Wang, R. K. (2010) · Optics Express · doi:10.1364/oe.18.008220 · Cited by 291
Polarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 288
Self-citationApplications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Self-citationInfectious Diseases: Preparing for the Future
King, D. A., Peckham, C., Waage, J. K., Brownlie, J., & Woolhouse, M. E. J. (2006) · Science · doi:10.1126/science.1129134 · Cited by 251
Zhang, Q., Zhong, S., & Zhong, J. (2015) · Advances in Mechanical Engineering · doi:10.1177/1687814015588726 · Cited by 250
“Equation (2) is a function of t, and it consists of several peaks positioned at t = 0, 6 (tn tm), and 6 (tr tn).”
Backgroundde Boer, J. F., Leitgeb, R., & Wojtkowski, M. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.003248 · Cited by 244
Advances in the microrheology of complex fluids
Waigh, T. A. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/7/074601 · Cited by 233
“Velocities can be measured using either the power spectral density of the intensity measured on the detector or the analysis of the phase of the Doppler shifted light [144].”
BackgroundMethodRetinal assessment using optical coherence tomography
Costa, R. A., Skaf, M., Melo, L. A. S., Calucci, D., Cardillo, J. A., Castro, J. C., Huang, D., & Wojtkowski, M. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.03.001 · Cited by 232
“This parameter is determined by the spectral bandwidth of the light source used in the OCT instrument (Drexler, 2004; Fercher et al., 2003).”
MethodDePond, P. J., Guss, G., Ly, S., Calta, N. P., Deane, D., Khairallah, S., & Matthews, M. J. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.05.050 · Cited by 222
Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
Wang, R. K., & An, L. (2009) · Optics Express · doi:10.1364/oe.17.008926 · Cited by 220
“Optical coherence tomography (OCT) [1,2] is a non-invasive imaging technology, capable of providing high resolution, depth resolved cross-sectional images of highly scattering sample, such as biological tissue, and is attracting more and more attention for both the medical and non-medical imaging applications since it…”
BackgroundPond, S. J. K., Tsutsumi, O., Rumi, M., Kwon, O., Zojer, E., Brédas, J.-L., Marder, S. R., & Perry, J. W. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049013t · Cited by 219
Gora, M., Karnowski, K., Szkulmowski, M., Kaluzny, B. J., Huber, R., Kowalczyk, A., & Wojtkowski, M. (2009) · Optics Express · doi:10.1364/oe.17.014880 · Cited by 217
Methods for Assessment of Dental Erosion
Attin, T., & Wegehaupt, F. J. (2014) · Monographs in Oral Science · doi:10.1159/000360355 · Cited by 208
Digital Ocular Fundus Imaging: A Review
Bernardes, R., Serranho, P., & Lobo, C. (2011) · Ophthalmologica · doi:10.1159/000329597 · Cited by 207
In situ morphology-based defect detection of selective laser melting through inline coherent imaging
Kanko, J. A., Sibley, A. P., & Fraser, J. M. (2016) · Journal of Materials Processing Technology · doi:10.1016/j.jmatprotec.2015.12.024 · Cited by 197
Maiti, R., Gerhardt, L.-C., Lee, Z. S., Byers, R. A., Woods, D., Sanz-Herrera, J. A., Franklin, S. E., Lewis, R., Matcher, S. J., & Carré, M. J. (2016) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.05.035 · Cited by 193
Balas, C. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/10/104020 · Cited by 179
Xing, H. Z., Zhang, Q. B., Braithwaite, C. H., Pan, B., & Zhao, J. (2017) · Rock Mechanics and Rock Engineering · doi:10.1007/s00603-016-1164-0 · Cited by 174
“1984), optical fibre sensors (Grattan and Meggitt 1995) and optical coherence tomography (Fercher et al. 2003).”
BackgroundMethodVisible-light optical coherence tomography: a review
Shu, X., Beckmann, L., & Zhang, H. F. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121707 · Cited by 173
“2,4 So far, SLDs have dominated in commercial OCT systems.”
BackgroundPodoleanu, A. G. (2005) · The British Journal of Radiology · doi:10.1259/bjr/55735832 · Cited by 170
Baumann, B., Baumann, S. O., Konegger, T., Pircher, M., Götzinger, E., Schlanitz, F., Schütze, C., Sattmann, H., Litschauer, M., Schmidt-Erfurth, U., et al. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001670 · Cited by 163
Self-citationGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
“These techniques, such as imaging the exposed cortex, different forms of microscopy, and optical coherence tomography (Fercher et al. 2003), have made a significant impact in oncology and neurophysiology and have been reviewed elsewhere (Weisslader & Ntziachristos 2003; Hillman 2007).”
MethodQuantum optical coherence tomography of a biological sample
Nasr, M. B., Goode, D. P., Nguyen, N., Rong, G., Yang, L., Reinhard, B. M., Saleh, B. E. A., & Teich, M. C. (2009) · Optics Communications · doi:10.1016/j.optcom.2008.11.061 · Cited by 79
Phase-conjugate optical coherence tomography
Erkmen, B. I., & Shapiro, J. H. (2006) · Physical Review A · doi:10.1103/physreva.74.041601 · Cited by 60
Metadata
- Authors
- Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2003-01-20
- Volume
- 66
- Issue
- 2
- Pages
- 239-303
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2078920062
- Cited by
- 1,866
- References
- 105
- FWCI
- 39.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.