Radiotherapy with beams of carbon ions
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
In cancer treatment, the introduction of MeV bremsstrahlung photons has been instrumental in delivering higher doses to deep-seated tumours, while reducing the doses absorbed by the surrounding healthy tissues. Beams of protons and carbon ions have a much more favourable dose-depth distribution than photons (called ‘x-rays’ by medical doctors) and are the new frontiers of cancer radiation therapy. Section 2 presents the status of the first form of hadrontherapy which uses beams of 200–250 MeV protons. The central part of this review is devoted to the discussion of the physical, radiobiological and clinical bases of the use of 400 MeV µ −1 carbon ions in the treatment of radio-resistant tumours. These resist irradiation with photon as well as proton beams. The following section describes the carbon ion facilities that are either running or under construction. Finally, the projects recently approved or proposed are reviewed here.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
Kanai, T., Endo, M., Minohara, S., Miyahara, N., Koyama-ito, H., Tomura, H., Matsufuji, N., Futami, Y., Fukumura, A., Hiraoka, T., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00544-6 · Cited by 889
Laser-driven proton scaling laws and new paths towards energy increase
Fuchs, J., Antici, P., d’Humières, E., et al. (2005) · Nature Physics · doi:10.1038/nphys199 · Cited by 788
Magnetic scanning system for heavy ion therapy
Haberer, T., Becher, W., Schardt, D., & Kraft, G. (1993) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(93)91335-k · Cited by 730
Self-citationClark, E. L., Krushelnick, K., Davies, J. R., Zepf, M., Tatarakis, M., Beg, F. N., Machacek, A., Norreys, P. A., Santala, M. I. K., Watts, I., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.670 · Cited by 729
Laser-plasma acceleration of quasi-monoenergetic protons from microstructured targets
Schwoerer, H., Pfotenhauer, S., Jäckel, O., Amthor, K.-U., Liesfeld, B., Ziegler, W., Sauerbrey, R., Ledingham, K. W. D., & Esirkepov, T. (2006) · Nature · doi:10.1038/nature04492 · Cited by 721
Laser acceleration of quasi-monoenergetic MeV ion beams
Hegelich, B. M., Albright, B. J., Cobble, J., Flippo, K., Letzring, S., Paffett, M., Ruhl, H., Schreiber, J., Schulze, R. K., & Fernández, J. C. (2006) · Nature · doi:10.1038/nature04400 · Cited by 701
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
Shirato, H., Shimizu, S., Kunieda, T., Kitamura, K., van Herk, M., Kagei, K., Nishioka, T., Hashimoto, S., Fujita, K., Aoyama, H., et al. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00748-3 · Cited by 662
Tumor therapy with heavy charged particles
Kraft, G. (2000) · Progress in Particle and Nuclear Physics · doi:10.1016/s0146-6410(00)00112-5 · Cited by 454
Self-citationKrämer, M., & Scholz, M. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/314 · Cited by 453
GeV laser ion acceleration from ultrathin targets: The laser break-out afterburner
YIN, L., ALBRIGHT, B. J., HEGELICH, B. M., & FERNÁNDEZ, J. C. (2006) · Laser and Particle Beams · doi:10.1017/s0263034606060459 · Cited by 327
Results of carbon ion radiotherapy in 152 patients
Schulz–Ertner, D., Nikoghosyan, A. V., Thilmann, C., Haberer, T., Jäkel, O., Karger, C. P., Kraft, G., Wannenmacher, M. F., & Debus, J. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.09.041 · Cited by 318
Self-citationUltrafast Laser-Driven Microlens to Focus and Energy-Select Mega-Electron Volt Protons
Toncian, T., Borghesi, M., Fuchs, J., d'Humières, E., Antici, P., Audebert, P., Brambrink, E., Cecchetti, C. A., Pipahl, A., Romagnani, L., et al. (2006) · Science · doi:10.1126/science.1124412 · Cited by 317
Instrumentation for treatment of cancer using proton and light-ion beams
Chu, W. T., Ludewigt, B. A., & Renner, T. R. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143946 · Cited by 313
Overview of clinical experiences on carbon ion radiotherapy at NIRS
Tsujii, H., Mizoe, J.-E., Kamada, T., Baba, M., Kato, S., Kato, H., Tsuji, H., Yamada, S., Yasuda, S., Ohno, T., et al. (2004) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(04)80012-4 · Cited by 213
Tumorigenic Potential of High-Z, High-LET Charged-Particle Radiations
Alpen, E. L., Powers-Risius, P., Curtis, S. B., & DeGuzman, R. (1993) · Radiation Research · doi:10.2307/3578551 · Cited by 178
Scholz, M., & Kraft, G. (1994) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a082156 · Cited by 170
Self-citationDiagnosis and Treatment of Pituitary Tumors
Freda, P. U. (1999) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.84.11.3859 · Cited by 158
Dikomey, E., Borgmann, K., Peacock, J., & Jung, H. (2003) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(03)00188-3 · Cited by 73
Kanematsu, N., Endo, M., Futami, Y., Kanai, T., Asakura, H., Oka, H., & Yusa, K. (2002) · Medical Physics · doi:10.1118/1.1521938 · Cited by 71
Cited by
Ion acceleration by superintense laser-plasma interaction
Macchi, A., Borghesi, M., & Passoni, M. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.751 · Cited by 1,460
Cucinotta, F. A., & Durante, M. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70695-7 · Cited by 697
Heavy ion carcinogenesis and human space exploration
Durante, M., & Cucinotta, F. A. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2391 · Cited by 578
“Research in this field is also essential for heavy-ion cancer therapy (hadrontherapy) on Earth, in which beams of high-energy carbon ions are used to sterilize solid cancer”
BackgroundCarbon ion radiotherapy in Japan: an assessment of 20 years of clinical experience
Kamada, T., Tsujii, H., Blakely, E. A., Debus, J., De Neve, W., Durante, M., Jäkel, O., Mayer, R., Orecchia, R., Pötter, R., et al. (2015) · The Lancet Oncology · doi:10.1016/s1470-2045(14)70412-7 · Cited by 562
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Metadata
- Authors
- Amaldi, U., & Kraft, G.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2005-07-11
- Volume
- 68
- Issue
- 8
- Pages
- 1861-1882
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2051627096
- Cited by
- 325
- References
- 20
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.