Limits to time variation of fundamental constants from comparisons of atomic frequency standards
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Time variation of the fundamental constants is one manifestation of the violation of Einstein's Equivalence Principle required by theories uniting gravitation with the strong and electroweak interactions. The rapid progress in the development of atomic frequency standards based on optical transitions is leading to ever more stringent constraints on time variation of the fine structure constant, α, which is the coupling constant of the electromagnetic interaction, and to quantities such as nuclear g -factors and mass ratios, which depend on the strong interaction. Absolute frequency measurements of these optical frequency standards currently place a limit on present-day time variation of the fine structure constant of (−4 ± 4) parts in 10 16 per year. There are good prospects for an improvement of two orders of magnitude in this limit by means of direct frequency comparisons between optical frequency standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Klitzing, K. V., Dorda, G., & Pepper, M. (1980) · Physical Review Letters · doi:10.1103/physrevlett.45.494 · Cited by 7,119
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
The Confrontation between General Relativity and Experiment
Will, C. M. (2006) · Living Reviews in Relativity · doi:10.12942/lrr-2006-3 · Cited by 1,606
Further Evidence for Cosmological Evolution of the Fine Structure Constant
Webb, J. K., Murphy, M. T., Flambaum, V. V., Dzuba, V. A., Barrow, J. D., Churchill, C. W., Prochaska, J. X., & Wolfe, A. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.091301 · Cited by 824
Search for Time Variation of the Fine Structure Constant
Webb, J. K., Flambaum, V. V., Churchill, C. W., Drinkwater, M. J., & Barrow, J. D. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.884 · Cited by 754
Spectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
New Limits on the Drift of Fundamental Constants from Laboratory Measurements
Fischer, M., Kolachevsky, N., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., Abgrall, M., Grünert, J., Maksimovic, I., Bize, S., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.230802 · Cited by 431
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
New Measurement of the Electron Magnetic Moment Using a One-Electron Quantum Cyclotron
Odom, B., Hanneke, D., D’Urso, B., & Gabrielse, G. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.030801 · Cited by 387
The Oklo bound on the time variation of the fine-structure constant revisited
Damour, T., & Dyson, F. (1996) · Nuclear Physics B · doi:10.1016/s0550-3213(96)00467-1 · Cited by 374
Srianand, R., Chand, H., Petitjean, P., & Aracil, B. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.121302 · Cited by 335
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Comparison between frequency standards in Europe and the USA at the 10−15uncertainty level
Bauch, A., Achkar, J., Bize, S., Calonico, D., Dach, R., Hlavać, R., Lorini, L., Parker, T., Petit, G., Piester, D., et al. (2006) · Metrologia · doi:10.1088/0026-1394/43/1/016 · Cited by 225
Implications of gauge unification for time variation of the fine structure constant
Langacker, P., Segrè, G., & Strassler, M. J. (2002) · Physics Letters B · doi:10.1016/s0370-2693(02)01189-9 · Cited by 193
�ber die magnetischen Momente der Atomkerne
Schmidt, T. (1937) · Zeitschrift f�r Physik · doi:10.1007/bf01338744 · Cited by 177
Atomic optical clocks and search for variation of the fine-structure constant
Dzuba, V. A., & Flambaum, V. V. (2000) · Physical Review A · doi:10.1103/physreva.61.034502 · Cited by 82
Neutron moderation in the Oklo natural reactor and the time variation ofα
Lamoreaux, S. K., & Torgerson, J. R. (2004) · Physical Review D · doi:10.1103/physrevd.69.121701 · Cited by 82
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
CODATA recommended values of the fundamental physical constants: 2006
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.633 · Cited by 952
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Self-citationUltralow noise miniature external cavity semiconductor laser
Liang, W., Ilchenko, V. S., Eliyahu, D., Savchenkov, A. A., Matsko, A. B., Seidel, D., & Maleki, L. (2015) · Nature Communications · doi:10.1038/ncomms8371 · Cited by 398
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Metadata
- Authors
- Lea, S. N.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 2007-08-20
- Volume
- 70
- Issue
- 9
- Pages
- 1473-1523
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2115842682
- Cited by
- 73
- References
- 20
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.